Auvon Dual Channel TENS Massager AS8012 User Manual
Content
Introduction
The Auvon Dual Channel TENS Massager AS8012 is an innovative pain relief device that utilizes Transcutaneous Electrical Nerve Stimulation (TENS) technology to alleviate discomfort. With up to 20 different modes, this portable unit allows users to customize their therapy experience, targeting specific areas of pain such as the back, shoulders, and joints. Its dual-channel functionality enables simultaneous treatment on two different body parts. The Auvon AS8012 is priced at $35.99.
Specifications
- Dual Channel: Treat two areas of the body at once
- Multiple Pre-set Programs: Includes programs for pain relief, muscle stimulation, and massage
- Adjustable Intensity: 20 levels of intensity for customized treatment
- Portable Design: Compact and lightweight, ideal for travel
- Battery Life: Up to 20 hours on a single set of batteries
- LED Display: Easy-to-read display showing program, intensity, and timer settings
- Ergonomic Design: User-friendly interface with simple buttons and controls
INCLUDED IN THIS STANDARD PACKAGE
- AUVON Dual Channel TENS Massager
- Square Pin Pads
- Rectangle Pin Pads
- Pads Holder
- Pouch
- Set of Lead Wires (½ Wire)
- USB Cable & USB Adapter
- User Manual
- Happy Card
FEATURES
- 2 output with 20 modes
- 20 level intensity
- 20 minutes default timer, can adjustable from 10-60 minutes
- Rechargeable lithium battery
- Battery indicator to know when need to recharge battery
- AC adapter 110-240V, USB Charger 5V
SAFETY PRECAUTIONS AND WARNINGS
DO NOT USE THIS UNIT UNDER THESE CONDITIONS
Consult with your physician before using this unit. The unit may cause lethal rhythm disturbances in certain susceptible individuals. If you have had a recent surgical procedure, the stimulation may disrupt the healing process.
Before using your unit, inspect these things.
- Cord is not broken.
- Pad gel is not damaged.
- Electrode cord connection is not broken.
- Unit is intact and working.
- There is no battery leakage.
DO NOT USE ON THESE INDIVIDUALS
- Pregnant women
- Do not use on children or infants because the device has not been evaluated for pediatric use
- Keep out of the reach of young children because the electrode cord could cause strangulation
- Persons incapable of expressing their thoughts or intentions.
- Persons incapable of operating the unit by themslelves.
- Use with caution if you have a tendency to bleed internally, such as following an injury or fracture.
- If you have suspected or diagnosed heart disease, you should follow precautions recommended by your physician.
- If you have suspected or dignosed epilepsy, you should follow precautions recommended by your physician
- Use caution if stimulation is applied over the menstruating uterus.
NEVER APPLY THE PADS TO THESE BODY AREAS:
- The head, the mouth, or any area of the face.
- The neck or any area of the throat because this could cause severe muscle spasms resulting in closure of the airway, difficulty in breathing, or adverse effects on heart rhythm or blood pressure.
- Do not use near the heart, or on genital area.
- Both sides of the thorax simultaneously (lateral or front and back), or across your chest because the introduction of electrical current may cause rhythm disturbances which could be lethal.
- On the calves of both legs at the same time because this may cause cardiac disturbance.
- On the bottom of both feet at the same time because this may cause cardiac disturbance. Open wounds or rashes or over swollen, red, infected or inflamed areas or skin eruptions (such as varicose veins, phlebitis, thrombophlebitis and thrombosis), or on top of or close to cancerous lesions, or over areas of skin that lack normal sensation.
DO NOT USE THIS UNIT DURING THESE ACTIVITIES
- When in bath or shower;
- While sleeping;
- While driving, operating machinery, or during any activity in which electrical stimulation can put you at risk of injury.
PAIN MANAGEMENT WARNINGS
- If you have had medical or physical treatment for your pain, consult with your physician before using this unit.
- If your pain does not improve, becomes serious chronic or severe, or continues for more than five years, stop using the unit and consult with your physician.
- The mere existence of pain functions as a very important warning telling us that something is wrong. Therefore, if you suffer from any serious illness, consult your physician in order to confirm that it is advisable for you to use this Power Relief unit.
PRECAUTIONS REGARDING THE PADS
- Do not move the pads to another location while the unit is on.
- Therapy won't work with just one pad. You MUST USE TWO PADS at the same time.
- Make sure the components are connected well and the pads are fixed on the part of the body you wish to treat or the therapy may not be effective.
- Pad should not touch any metal object, such as belt buckle, necklace, or other metal worn under clothing.
- Do not overlap pads or put pads on top of each other. It may weaken or stop therapy, or the unit may stop working. Gel pads may also stick together and cause gel to be removed when separating.
- Do not share pads with another person. This may cause a skin irritation or infection. Pads are intended for use by one person.
- Do not leave pads attached to the skin after treatment.
- Do not bend or fold because the gel may get damaged and it won't stick or function properly.
- To avoid damage to the adhesive surface to the pads, put the pads only on the skin or on the plastic pad holder provided to avoid damage to the adhesive surface of the pads.
- Always place clean pads in accordance with illustrations provided.
- Do not apply ointment or any solvent to the pads or to your skin because it will disrupt the pads from functioning properly. The self-adhesive pads will adhere to your skin.
HOW DOES IT WORK?
Scientific theory suggests that electrical stimulation therapy may work in several ways:
- The gentle electrical pulse move through the skin to nearly nerves to block or shut out the pain message from the source of the pain to reaching the brain.
- The gentle electrical pulse increases the production of the body's natural painkiller, such as endorphins.
- Furthermore, it is thought that the electrical stimulation improves blood circulation as well.
Muscles contract and relax with the flow of the electrical stimulation. With the replated contracting and relaxing, the blood flows in and out and the blood circulation improved.
Description
The Auvon Dual Channel TENS Massager AS8012 is a sleek and user-friendly device that combines advanced technology with ease of use. The dual-channel feature allows for the simultaneous treatment of two different areas, making it highly efficient. The device comes with multiple pre-set programs tailored to various types of pain and muscle issues, ensuring that you can find the perfect setting for your needs. The adjustable intensity levels further enhance the personalization of your treatment sessions.
The massager is powered by batteries, making it portable and convenient to use anywhere. The LED display provides clear visibility of the selected program, intensity level, and timer, ensuring you are always in control of your treatment.
OPERATING INSTRUCTIONS
HOW TO USE
- Clean your skin before use. Use the pads on clean and flat areas, no sweat, no oil.
- Attach one pair or two pairs of the electrode pads to the massager area, such as shoulder and leg.
Note: Adding a few drops of water on the pads and drying the pads naturally will increase their longevity. Make sure both pads on the skin and not overlapping. - Connect a pair of electrode pads to one lead wire by plug them on; the other end of the wire is connected to the left output of the device. Similarly, the other pair of electrode pads is connected to the remaining wire end and the right output of the device.
- Turn on the device by sliding the on/ off switch on the top of the unit.
- Press the A button to choose Channel A.
Press the M button to try different mode and press +/- to increase or decrease intensity. Press the B button to choose Channel B and select your favorite mode and intensity (The modes on Channel A can be different with that on Channel B).
Note: Remember the strength will default to the lowest setting by each mode selection. - Recommended application is 10-60 minutes. Increase 10 minutes by each setting by pressing the T on the device. The time remaining is automatically counted down until it turns off once the time finishes.
- Press and hold the center button for 3 seconds to lock the screen, 3 seconds again to unlock the screen.
AFTER USE
- Turn off the device on by sliding the on/ off switch on the top of the unit.
- Remove lead wire pin from electrode connector by gently twisting and pulling it out.
- Lift a corner of the electrode and slowly peel it away. Avoid touching the gel as much as possible.
DO NOT peel the electrode off by the wire. - Remove the electrodes back to the storage bag and reseal tightly to prevent dry-out. Store at room or cool temperature and keep out of direct sunlight.
RECOMMEND MASSAGE POINTS
ILLUSTRATIONS OF THE DEVICE AND ACCESSORIES
- On / off switch
- USB port
- Time
- Battery indicator
- Adjustable Intensity (A Channel)
- Adjustable Intensity (B Channel)
- Intensity Decrease
- Channel A
- Lock
- Mode Selection
- Intensity Increase
- Channel B
- Time Selection
- Two output connector
Icon & Mode | Name | Description | |
Simulating | |||
1 | Tuina | Tuina is a | |
hands-on body | |||
treatment which | |||
2 | Tuina- ombination | opens the flow of Qi through | |
the meridians | |||
Simulating | |||
3 | Tapping | tapping is | |
intended to | |||
produce a | |||
4 | Tapping- ombination | hard thumping sensation that massage your | |
muscles |
|
5 |
Acupuncture |
Simulating acupuncture provides the same sensation withoutneedles |
6 |
Acupuncture- Combination | ||
|
7 |
Thai massage |
Simulating Thai massage to relex your deep layers of muscles |
8 | Thai massage- Combination | ||
|
9 |
Palm kneading | Simulating the feeling of using fingersand palm to apply weight to the body |
10 | Palm kneading- Combination | ||
|
11 |
Cupping | Stimulating cupping, relatively constant stimulation contracts muscles |
12 |
Cupping- Combination |
13 | Lifting pinching manipulation |
Simulating the thumb and index fingerlift the skin | |
14 | Lifting pinching- Combination | ||
15 |
Scrapeing |
Stimulating the feeling of scrap over skin with a smoothedged instrument | |
16 |
Scrapeing- Combination | ||
17 | Tapping- Kneading- Pushing |
Auto combination of Tapping- Kneading- Pushing | |
18 | Auto- Combination 1 | ||
19 | Auto- Combination 2 |
Auto combination of several modesfor relaxation | |
20 | Auto- Combination 3 |
Setup Guide
To operate the Auvon Dual Channel TENS Massager AS8012, follow these steps:
- Insert the batteries into the device according to the polarity indicated.
- Attach the electrode pads to the desired areas of your body, ensuring good skin contact.
- Turn on the device by pressing the power button.
- Select the desired program using the program button.
- Adjust the intensity level using the plus (+) and minus (-) buttons until you find a comfortable setting.
- Set the timer if desired and start your treatment session.
TENS PADS HOLDER
FEATURES
INSTRUCTION
- Stick the electrode patches on the holder to avoid getting dust.
Wind the thread around the holder for easy use as the picture shown.
MAINTENANCE AND CARE
- When you are finished using the device, turn it off and take off the pads. Store the unit in a cool,dry place until next use.
- After usage, please cover the pads with the protective film and put them back in their zip lock bags. Applying a few drops water before and after usage will increase the longevity of the pads.
Or stick the electrode patches on the holder and wind the thread around the holder. - Charge the unit at least every 3 month in event it is not used regularly.You can also use the unit with wall charger or directly from your computer using the USB cable.
Warning:
- The stimulator has no any output when it is being charged. You must take off the electrode pads from your body before the stimulator charged.
- Charging only with this AC adaptor (Model: GDP06AV-0500550-UL, manufacturer: Shenzhen Guandexin Technology Co., Ltd ).
Operation environmental for adapter
Normal workingambient temperature | 5~40℃ |
Normal working ambient humidity and Atmosphere pressure |
≤80%RH; Atmosphere Pressure: 700 ~1060hPa |
Store and transport ambient temperature | -20~55℃ |
Store and transport ambient humidity and Atmosphere pressure |
≤93%RH; Atmosphere Pressure: 700 ~1060hPa |
Charger | Input:100-240V 50/60Hz0.18A Max Output: DC5V |
The combination of stimulator and AC adaptor is considered as medical electrical system. The AC adaptor is not considered as part of ME equipment ME system
Charging the Battery
- Turn off the controller.
- Connect the controller and the charger with USB extension cord. Plug charger into any power outlet, green light shows charging. The charging process will last approximately 1 hour.
General technological characteristics | - Input | 100-240VAC 50/60Hz 0.25A |
- Output | DC5V | |
Complied standards | IEC60950 | |
Labeling on the AC charger | ||
How it is connected to the device |
Note: Only charge the controller when battery is completely drained the first 2 times. Unplug charger from power outlet when charging is complete. When massage strength decreases, it indicates that the device needs charging. Recharge it and then continue to use the device. Do not use the controller when charging.
TROUBLESHOOTING
If your device is not operating properly, please check below for common problems and suggested solutions. If the recommended action does not solve the problem, please contact the seller.
Problem | Possible Cause | Solution |
One pad feelsstronger than the other | This is normal. Different area of your body will react differently | Nothing needs to be done. Make sure the pads are moist and making good contact. |
The skin turns red or the skin feels irritated |
The adhesive the surface of the pads is dirty or dry | Wash adhesive the surface of pads gently with your fingertips for about 3 seconds under slow running water |
The therapy time is too long or the intensity is set too high |
Reduce the application time or reduce the intensity | |
The electrode pad surface is worn out | Replace electrode pad |
The intensity is not felt with a very weak intensitylevel | Pads are not attached to the body firmly |
Attach bothpads firmly to the skin |
The transparent films are still stuck to the pads |
Peel off film on the adhesive surface of pads | |
The pads stack together or overlap | Do not stack pads together or overlap pads | |
The cord is not properly connected to the unit | Connect cord correctly into the jack | |
The intensity of the setting is getting weak |
Increase the intensity level | |
The battery capacity is low |
Charge the battery | |
No power source; no display on LCD. | The battery capacity is depleted |
Charge the battery |
It is difficult to attach the pad to the skin | Have you remove the transparent film from the pad? |
Peel off film on the adhesive surface of pads |
Was the pad applied immediately after washing? |
Dry the pad | |
Is the adhesive on the surface of the pad damaged? |
Replace the pad | |
Power cuts off during use | The battery is weak | Charge the battery |
The cord is broken | Replace the cord | |
Adhesive on the surface of a pads not sticky | Pads get deteriorative | Contact the vendor for replacements |
Were the pads stored under high temperature, high humidity, or direct sunshine? |
Replace the pad |
The AUVON TENS Massager is with 10 Massage Modes, and totally 20 Sub-mode Choices.
Auvon Dual Channel TENS Massager AS8012 Warranty
24-Month Limited Warranty
Warranty Extension:
Register with https://www.iauvon.com/register you could have 36 Months Free warranty
Pros & Cons
Pros
- Dual-channel capability for treating two areas simultaneously
- Multiple pre-set programs for various types of pain relief
- Adjustable intensity levels for personalized treatment
- Portable and lightweight design
Cons
Customer Reviews
Customers have generally praised the Auvon Dual Channel TENS Massager AS8012 for its effectiveness in relieving muscle pain and tension. Many users appreciate its ease of use and the variety of pre-set programs available. However, some users have reported minor skin irritation and wished for more electrode pads to be included.
Faqs
What is the primary purpose of the Auvon?
How do I know which program to use on my Auvon TENS Massager?
How long does the battery last on the Auvon Dual Channel TENS Massager AS8012?
Can I purchase additional electrode pads for my Auvon Dual Channel TENS Massager?
How do I clean and maintain my Auvon?
What should I do if I experience skin irritation while using the TENS Massager?
Is there a warranty on the Auvon Dual Channel TENS Massager AS8012?
Can I use the Auvon TENS Massager during pregnancy?
Leave a Comment