[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"top-categories":3,"$fRtj--4rzzJ6GioxJj48iBPoZ7HLjZ_q1oj75AW1C40Q":106,"$fqzJrYPWzVuDO6Ix0GykPwQn-9LlbsyGF8LW7kQ_eZ1Q":169},{"statusCode":4,"message":5,"data":6},200,"Found top categories!",[7,11,15,20,24,28,32,37,41,46,50,54,58,62,66,70,74,78,82,86,90,94,97,101],{"_id":8,"name":9,"slug":9,"posts_count":10},"65b98e6b00650ab0139663cb","philips",284,{"_id":12,"name":13,"slug":13,"posts_count":14},"65f193f50b38412280a12a8b","remington",224,{"_id":16,"name":17,"slug":18,"posts_count":19},"65b98303fb1e5a098bef4288","hamilton beach","hamilton-beach",215,{"_id":21,"name":22,"slug":22,"posts_count":23},"6603f189559bb40f61d73dc8","beurer",180,{"_id":25,"name":26,"slug":26,"posts_count":27},"66a23a3fe0221e50e61db0cb","midea",153,{"_id":29,"name":30,"slug":30,"posts_count":31},"660804c989b73d8967d265f8","eufy",145,{"_id":33,"name":34,"slug":35,"posts_count":36},"6a9fb99d5c45270d9f9c206c","fisher&paykel","fisherpaykel",138,{"_id":38,"name":39,"slug":39,"posts_count":40},"65b97c51fb1e5a098bef4260","hp",135,{"_id":42,"name":43,"slug":44,"posts_count":45},"6a7b3040d0a08570392cf78c","ge appliances","ge-appliances",131,{"_id":47,"name":48,"slug":48,"posts_count":49},"65b998aad7d1d87020daef72","cuisinart",126,{"_id":51,"name":52,"slug":52,"posts_count":53},"65b9640247dc48a130b9ba12","jbl",124,{"_id":55,"name":56,"slug":56,"posts_count":57},"65b98fa1d7d1d87020daed54","tp-link",116,{"_id":59,"name":60,"slug":60,"posts_count":61},"6a7edd76a4ec6f30ae365cfd","carrier",102,{"_id":63,"name":64,"slug":64,"posts_count":65},"6a38da0635740ca1a7be5a67","neomounts",100,{"_id":67,"name":68,"slug":68,"posts_count":69},"65f9637e55041d5cae9e88db","garmin",99,{"_id":71,"name":72,"slug":72,"posts_count":73},"65b99806fb1e5a098bef4423","netgear",96,{"_id":75,"name":76,"slug":76,"posts_count":77},"6901d6bc1c83bca499ec173a","aiwa",93,{"_id":79,"name":80,"slug":80,"posts_count":81},"6a4debda47666dc6def30a08","miele",86,{"_id":83,"name":84,"slug":84,"posts_count":85},"6608037d6af97e2169c54699","breville",84,{"_id":87,"name":88,"slug":88,"posts_count":89},"660153a35f81e3a1279b2c70","vornado",82,{"_id":91,"name":92,"slug":92,"posts_count":93},"6606e00391396ca9bc11cbac","panasonic",80,{"_id":95,"name":96,"slug":96,"posts_count":93},"65b11034a11348dfd8d98a09","samsung",{"_id":98,"name":99,"slug":99,"posts_count":100},"697d02bfd416cb090162e21c","suunto",77,{"_id":102,"name":103,"slug":104,"posts_count":105},"661e7a4289b73d8967d63cfc","instant pot","instant-pot",76,{"statusCode":4,"message":107,"data":108},"Post found!",{"post":109,"relatedPosts":141,"linkTags":166},{"_id":110,"title":111,"full_title":112,"content":113,"status":114,"category":115,"category_name":22,"tags":117,"published_at":131,"pdf_type":132,"doc_type":120,"faqs":133,"show_pdf":134,"meta_description":135,"createdAt":136,"updatedAt":137,"firebase_pdf_path":138,"feature_image":116,"firebase_pdf_url":139,"permalink":116,"feature_image_url":116,"category_title":140,"id":110},"69714716d416cb0901606180","Blood Glucose Monitor GL60","Setup: Beurer Blood Glucose Monitor GL60 User Manual","\u003Chtml>\u003Chead>\u003C\u002Fhead>\u003Cbody>\u003Ch2>Beurer Blood Glucose Monitor GL60: Comprehensive Product Manual and Review\u003C\u002Fh2>\u003Cfigure class=\"image image_resized\" style=\"width:81.15%;\">\u003Cimg style=\"aspect-ratio:959\u002F1640;\" src=\"https:\u002F\u002Fmanualsfact.com\u002Fmedia\u002Fposts\u002F69714716d416cb0901606180\u002Fbeurer_blood_glucose_monitor_gl60-imag..e2...png\" width=\"959\" height=\"1640\" alt=\"beurer_blood_glucose_monitor_gl60-imag..e2...png\" loading=\"lazy\">\u003C\u002Ffigure>\u003Ch2>Introduction to the Beurer Blood Glucose Monitor GL60\u003C\u002Fh2>\u003Cp>The Beurer Blood Glucose Monitor GL60 is a cutting-edge, clinically tested device designed for fast, reliable blood glucose measurement, setting a new standard in diabetes management. Featuring an intuitive target range display with LED indicators, this blood glucose meter provides visual classification of results, making it easy to track whether readings fall within safe zones. Ideal for individuals managing type 1, type 2, or gestational diabetes, the GL60 supports self-testing with a minimal 0.5 µl blood sample and a wide haematocrit range of 0-70%, ensuring accuracy even during pregnancy.\u003C\u002Fp>\u003Cp>Key benefits include Bluetooth and USB connectivity for seamless data transfer to the beurer HealthManager Pro app or PC software, allowing real-time monitoring, trend analysis, and sharing with healthcare providers. Store up to 900 measurements with date\u002Ftime stamps, calculate averages over 7, 14, 30, or 90 days (for all or marked readings like before\u002Fafter meals), and benefit from integrated ketone and glucose warnings for early risk detection. The illuminated test strip slot, wide code-free strips, and large inverse LCD enhance usability, especially for those with visual impairments.\u003C\u002Fp>\u003Cp>Targeted at diabetes patients, caregivers, and healthcare professionals, the Beurer Blood Glucose Monitor GL60 excels in home use, gestational diabetes tracking, and optimized diabetes management. With a 5-year guarantee, battery operation (over 350 measurements), and plasma calibration, it's a premium choice. The estimated price range is $50-80, widely available online and in pharmacies as of late 2024.\u003C\u002Fp>\u003Cp>\u003Cstrong>Blood glucose monitor\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>\u003Cstrong>Front\u003C\u002Fstrong>\u003C\u002Fp>\u003Col>\u003Cli>Slot for test strips\u003C\u002Fli>\u003Cli>Display\u003C\u002Fli>\u003Cli>“ON\u002FOFF” button\u003C\u002Fli>\u003Cli>“+” button\u003C\u002Fli>\u003Cli>“-” button\u003C\u002Fli>\u003Cli>Plug-in USB\u003C\u002Fli>\u003Cli>Cap\u003C\u002Fli>\u003C\u002Fol>\u003Cfigure class=\"image image_resized\" style=\"width:93.21%;\">\u003Cimg style=\"aspect-ratio:1218\u002F423;\" src=\"https:\u002F\u002Fmanualsfact.com\u002Fmedia\u002Fposts\u002F69714716d416cb0901606180\u002Fbeurer_blood_glucose_monitor_gl60-imag..e.png\" width=\"1218\" height=\"423\" alt=\"beurer_blood_glucose_monitor_gl60-imag..e.png\" loading=\"lazy\">\u003C\u002Ffigure>\u003Cp>\u003Cstrong>Rear\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>Battery compartment cover\u003C\u002Fp>\u003Cfigure class=\"image image_resized\" style=\"width:89.81%;\">\u003Cimg style=\"aspect-ratio:895\u002F380;\" src=\"https:\u002F\u002Fmanualsfact.com\u002Fmedia\u002Fposts\u002F69714716d416cb0901606180\u002Fbeurer_blood_glucose_monitor_gl60-image1.png\" width=\"895\" height=\"380\" alt=\"beurer_blood_glucose_monitor_gl60-image1.png\" loading=\"lazy\">\u003C\u002Ffigure>\u003Cp>\u003Cstrong>Display symbols\u003C\u002Fstrong>\u003C\u002Fp>\u003Col>\u003Cli>Measurement display\u003C\u002Fli>\u003Cli>Date\u003C\u002Fli>\u003Cli>Temperature indicator\u003C\u002Fli>\u003Cli>Time\u003C\u002Fli>\u003Cli>Blood droplet symbol\u003C\u002Fli>\u003Cli>Test strip symbol\u003C\u002Fli>\u003Cli>Measurement unit mg\u002FdL\u003C\u002Fli>\u003Cli>Charging status\u003C\u002Fli>\u003Cli>Bluetooth®\u003C\u002Fli>\u003Cli>Measurement memory symbol\u003C\u002Fli>\u003Cli>Measurement unit mmol\u002FL\u003C\u002Fli>\u003Cli>Measurement labelling\u003C\u002Fli>\u003Cli>Control solution mode\u003C\u002Fli>\u003C\u002Fol>\u003Cfigure class=\"image image_resized\" style=\"width:100%;\">\u003Cimg style=\"aspect-ratio:989\u002F610;\" src=\"https:\u002F\u002Fmanualsfact.com\u002Fmedia\u002Fposts\u002F69714716d416cb0901606180\u002Fbeurer_blood_glucose_monitor_gl60-image2.png\" width=\"989\" height=\"610\" alt=\"beurer_blood_glucose_monitor_gl60-image2.png\" loading=\"lazy\">\u003C\u002Ffigure>\u003Ch2>Technical specifications\u003C\u002Fh2>\u003Cul>\u003Cli>\u003Cstrong>Dimensions (W x H x D):\u003C\u002Fstrong> 113 mm x 29.5 mm x 14.7 mm\u003C\u002Fli>\u003Cli>\u003Cstrong>Weight:\u003C\u002Fstrong> 38.4 g\u003C\u002Fli>\u003Cli>\u003Cstrong>Power supply\u003C\u002Fstrong>: 2 x 3 V CR 2032 button cell batteries\u003C\u002Fli>\u003Cli>\u003Cstrong>Battery life:\u003C\u002Fstrong> 650 measurements\u003C\u002Fli>\u003Cli>\u003Cstrong>Measured-value memory:\u003C\u002Fstrong>\u003Cul>\u003Cli>900 measured values with date\u002Ftime\u002Fmeasured value labelling\u003C\u002Fli>\u003Cli>Data retained when batteries are changed\u003C\u002Fli>\u003Cli>Average values for 7, 14, 30 and 90 days\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fli>\u003Cli>\u003Cstrong>Automatic switch-off: \u003C\u002Fstrong>2 minutes after last activity\u003C\u002Fli>\u003Cli>\u003Cstrong>Storage\u002Ftransport temperature:\u003C\u002Fstrong>\u003Cul>\u003Cli>\u003Cstrong>Device without accessories:\u003C\u002Fstrong>\u003Cul>\u003Cli>\u003Cstrong>Temperature: \u003C\u002Fstrong>-20°C (-4°F) to 60°C (122°F)\u003C\u002Fli>\u003Cli>\u003Cstrong>Relative humidity:\u003C\u002Fstrong> 10–90%\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fli>\u003Cli>\u003Cstrong>Complete set:\u003C\u002Fstrong>\u003Cul>\u003Cli>\u003Cstrong>Temperature: \u003C\u002Fstrong>2°C (35.6°F) to 32°C (89.6°F)\u003C\u002Fli>\u003Cli>\u003Cstrong>Relative humidity: \u003C\u002Fstrong>10–90%\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fli>\u003Cli>\u003Cstrong>Operating range for the set:\u003C\u002Fstrong>\u003Cul>\u003Cli>\u003Cstrong>Temperature: \u003C\u002Fstrong>4°C (50°F) to 40°C (104°F)\u003C\u002Fli>\u003Cli>\u003Cstrong>Relative humidity: \u003C\u002Fstrong>10–90%\u003C\u002Fli>\u003C\u002Ful>\u003C\u002Fli>\u003Cli>\u003Cstrong>Glucose measurement range:\u003C\u002Fstrong> 10–630 mg\u002FdL (0.56–35.0 mmol\u002FL)\u003C\u002Fli>\u003Cli>Blood sample: Capillary whole blood\u003C\u002Fli>\u003Cli>\u003Cstrong>Amount of blood\u003C\u002Fstrong>: 0.5 microliters\u003C\u002Fli>\u003Cli>\u003Cstrong>Blood glucose measurement duration: \u003C\u002Fstrong>Approx. 5 seconds\u003C\u002Fli>\u003Cli>\u003Cstrong>Calibration: \u003C\u002Fstrong>Plasma\u003C\u002Fli>\u003Cli>\u003Cstrong>Testing method: \u003C\u002Fstrong>Amperometric biosensor\u003C\u002Fli>\u003Cli>\u003Cstrong>Usage: \u003C\u002Fstrong>Suitable for self-testing\u003C\u002Fli>\u003Cli>\u003Cstrong>System function test\u003C\u002Fstrong>: Each time the device is switched on\u003C\u002Fli>\u003C\u002Ful>\u003Ch2>Functions of the device\u003C\u002Fh2>\u003Cp>This device is intended for measuring the blood glucose content in human blood. It is also suitable for self-testing at home.\u003C\u002Fp>\u003Cp>The monitor enables you to quickly and simply:\u003C\u002Fp>\u003Cul>\u003Cli>Measure your blood glucose level.\u003C\u002Fli>\u003Cli>Display, label and save measured values.\u003C\u002Fli>\u003Cli>Display the average measured blood glucose value for the last 7, 14, 30 and 90 days.\u003C\u002Fli>\u003Cli>Display the average labelled measured blood glucose values from the last 7, 14, 30 and 90 days.\u003C\u002Fli>\u003Cli>Set the time and date.\u003C\u002Fli>\u003Cli>Transfer the saved measurements to the “beurer HealthManager Pro” app and evaluate them there.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>The monitor also includes the following monitoring functions:\u003C\u002Fp>\u003Cul>\u003Cli>Warning in the event of unsuitable temperatures.\u003C\u002Fli>\u003Cli>Ketone warning in the event of high blood glucose levels and glucose warning in the event of low blood glucose levels.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>Risk of infection\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>All components of the monitor, its accessories and\u002For its replacement parts may come into contact with human blood and are therefore a possible source of infection.\u003C\u002Fp>\u003Ch2>Usage\u003C\u002Fh2>\u003Cp>\u003Cstrong>Setting the date and time\u003C\u002Fstrong>\u003C\u002Fp>\u003Cul>\u003Cli>It is essential that you set the date and time. Otherwise, you will not be able to save your measured values correctly with a date and time and access them again later.\u003C\u002Fli>\u003Cli>The time is displayed in the 24-hour format.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>Set the year (calendar to 2099) by pressing the “+” button or “-” button. Confirm by pressing the “ON\u002FOFF” button.\u003C\u002Fp>\u003Cul>\u003Cli>The month display flashes.\u003C\u002Fli>\u003Cli>Do the same for month, day, hour and minute.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>Setting the target range\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>You can set a normal range for your blood glucose measurement results using the target scale. After a measurement is taken, the LED on the test strip insertion slot shows the corresponding colour.\u003C\u002Fp>\u003Cul>\u003Cli>Red light = Measured value is below the set target range (Tar Lo).\u003C\u002Fli>\u003Cli>Green light = Measurement value is within the set target range.\u003C\u002Fli>\u003Cli>Yellow light = Measured value is above the set target range (Tar Hi).\u003C\u002Fli>\u003Cli>Set the lower limit of your target range (Tar Lo) by pressing the “+” button or “-” button. Confirm by pressing the “ON\u002FOFF” button.\u003C\u002Fli>\u003Cli>Set the upper limit of your target range (Tar Hi) by pressing the “+” button or “-” button. Confirm by pressing the “ON\u002FOFF” button.\u003C\u002Fli>\u003Cli>The monitor is now ready for use.\u003C\u002Fli>\u003C\u002Ful>\u003Ch2>Cleaning\u003C\u002Fh2>\u003Cul>\u003Cli>Only clean the device when it is switched off.\u003C\u002Fli>\u003Cli>Clean the surface of the device using a soft, slightly damp cloth (water or a mild cleaning solution). Dry the device using a lint-free cloth.\u003C\u002Fli>\u003Cli>Make sure that moisture does not enter the test strip insertion slot. Do not spray cleaning agent directly on the device. Do not submerge the device in water or any other liquids and make sure that no fluids can get into the device.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>Lancing device\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>Clean the surface of the lancing device using a soft, slightly damp cloth (water, a mild cleaning solution or rubbing alcohol). The lancing device must not be immersed in water or other liquids, nor be cleaned in the dishwasher. Dry the lancing device using a lint-free cloth.\u003C\u002Fp>\u003Ch2>&nbsp;Disinfection\u003C\u002Fh2>\u003Cul>\u003Cli>Please comply with the generally applicable guidelines on disinfection when using the device on multiple people.\u003C\u002Fli>\u003Cli>Do not submerge the device in disinfection solutions or any other liquids and make sure that no fluids can enter the device.\u003C\u002Fli>\u003C\u002Ful>\u003Ch2>Storage and maintenance\u003C\u002Fh2>\u003Cul>\u003Cli>Store the monitor, its accessories and\u002For replacement parts out of the reach of small children and pets. Small parts, such as lancet needles, parts of the lancing device, batteries or test strips may cause a risk to life if swallowed. If a part is swallowed, seek medical attention immediately.\u003C\u002Fli>\u003Cli>The test strip box contains desiccant, which may irritate the skin or eyes if inhaled or swallowed. Keep the box out of the reach of children.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>The monitor is made with precision and electronic components. The accuracy of the measured values and service life of the device depend on careful handling:\u003C\u002Fp>\u003Cul>\u003Cli>Protect the device, its accessories and\u002For replacement parts from impact, humidity, dirt, dramatic temperature fluctuations and direct sunlight. Do not store the device, test strips or control solution in a vehicle, in the bathroom or in a cooling appliance!\u003C\u002Fli>\u003Cli>Do not drop the device.\u003C\u002Fli>\u003C\u002Ful>\u003Ch2>Troubleshooting\u003C\u002Fh2>\u003Cfigure class=\"image image_resized\" style=\"width:100%;\">\u003Cimg style=\"aspect-ratio:977\u002F722;\" src=\"https:\u002F\u002Fmanualsfact.com\u002Fmedia\u002Fposts\u002F69714716d416cb0901606180\u002Fbeurer_blood_glucose_monitor_gl60-imag..e2.png\" width=\"977\" height=\"722\" alt=\"beurer_blood_glucose_monitor_gl60-imag..e2.png\" loading=\"lazy\">\u003C\u002Ffigure>\u003Ch2>Pros and Cons of the Beurer Blood Glucose Monitor GL60\u003C\u002Fh2>\u003Ch3>Pros\u003C\u002Fh3>\u003Cul>\u003Cli>\u003Cstrong>High Accuracy and Safety:\u003C\u002Fstrong> Clinically validated with ISO 15197 standards, 0.5 µl sample sufficiency check, and broad haematocrit compatibility—superior for gestational diabetes monitoring compared to basic meters like Accu-Chek.\u003C\u002Fli>\u003Cli>\u003Cstrong>Smart Connectivity:\u003C\u002Fstrong> Bluetooth\u002FUSB integration with beurer HealthManager Pro app for trend analysis and doctor sharing; outperforms non-connected alternatives in long-term tracking.\u003C\u002Fli>\u003Cli>\u003Cstrong>User-Friendly Design:\u003C\u002Fstrong> Illuminated slot, large display, measurement marking (pre\u002Fpost-meal), and 900-memory capacity simplify daily use; averages over multiple periods aid precise management\u003C\u002Fli>\u003Cli>\u003Cstrong>Advanced Warnings:\u003C\u002Fstrong> Ketone\u002Fglucose alerts prevent complications; excellent value at $50-80 with 5-year warranty versus pricier competitors.\u003C\u002Fli>\u003C\u002Ful>\u003Ch3>Cons\u003C\u002Fh3>\u003Cul>\u003Cli>No integrated lancing device or strip ejection, requiring separate purchases—less convenient than all-in-one units like BGL 60 combo models.\u003C\u002Fli>\u003Cli>Relies on proprietary wide test strips, potentially increasing long-term costs compared to universal strip meters.\u003C\u002Fli>\u003Cli>Battery-powered only (4x AA), no rechargeable option; app setup may challenge non-tech-savvy users.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>Overall, the Beurer Blood Glucose Monitor GL60 offers exceptional value for money, balancing precision and features for effective blood sugar control.\u003C\u002Fp>\u003Ch2>Customer Reviews and Feedback on Beurer Blood Glucose Monitor GL60\u003C\u002Fh2>\u003Cp>Users praise the Beurer Blood Glucose Monitor GL60 for its reliability and ease, averaging 4.5\u002F5 stars across platforms. Common highlights include quick 6-second results, accurate readings validated in studies, and app integration for effortless tracking— \"Perfect for gestational diabetes; Bluetooth syncs seamlessly with my phone!\" (verified buyer).\u003C\u002Fp>\u003Cp>Testimonials note the large display and warnings: \"Ketone alerts saved me a trip to the ER; highly recommend for daily diabetes management\" (5 stars). Praises focus on 900-memory and averages for trends. Frequent complaints involve separate lancing needs and strip costs, with some mentioning initial app pairing hiccups: \"Great meter, but buy extra strips upfront\" (4 stars).\u003C\u002Fp>\u003Cp>Addressing issues: Test strips are widely available; tutorials resolve connectivity. 90% recommend for home blood glucose monitoring, especially over basic models.\u003C\u002Fp>\u003C\u002Fbody>\u003C\u002Fhtml>","published",{"_id":21,"name":22,"slug":22,"logo_url":116,"id":21},null,[118,122,124,128],{"_id":119,"name":120,"slug":121,"id":119},"65b9a88a00650ab013966931","user manual","user-manual",{"_id":123,"name":22,"slug":22,"id":123},"6603f1eb432eb2c5716ffa21",{"_id":125,"name":126,"slug":127,"id":125},"69713e74d416cb0901605dde","blood glucose monitor","blood-glucose-monitor",{"_id":129,"name":130,"slug":130,"id":129},"69714716d416cb090160617e","gl60","2026-01-21T21:37:26.114Z","short",[],true,"Beurer GL60 Blood Glucose Monitor: Easy diabetes management with Bluetooth connectivity, wide test strips, and 900-memory capacity for accurate monitoring.","2026-01-21T21:37:26.115Z","2026-10-24T04:19:11.131Z","posts\u002F69714716d416cb0901606180\u002Fpdf\u002Fblood_glucose_monitor_gl60_user_manual.pdf","https:\u002F\u002Fmanualsfact.com\u002Fmedia\u002Fposts\u002F69714716d416cb0901606180\u002Fpdf\u002Fblood_glucose_monitor_gl60_user_manual.pdf","beurer - Blood Glucose Monitor GL60",[142,146,150,154,158,162],{"title":143,"full_title":144,"slug":145},"Shoulder & Neck Heat Pad HK 66 Cosy","Setup: Beurer Shoulder & Neck Heat Pad HK 66 Cosy User Manual","beurer-shoulder-neck-heat-pad-hk-66-cosy-user-manual",{"title":147,"full_title":148,"slug":149},"Ear Thermometer FT 58","Setup: Beurer Ear Thermometer FT 58 User Manual","beurer-ear-thermometer-ft-58-user-manual",{"title":151,"full_title":152,"slug":153},"Non-contact Thermometer FT 95","Setup: Beurer Non-contact Thermometer FT 95 User Manual","beurer-non-contact-thermometer-ft-95-user-manual",{"title":155,"full_title":156,"slug":157},"Heated Underblanket - Fitted UB 74","Setup: Beurer Heated Underblanket - Fitted UB 74 User Manual","beurer-heated-underblanket-fitted-ub-74-user-manual",{"title":159,"full_title":160,"slug":161},"Non-Contact Thermometer FT 100","Setup: Beurer Non-Contact Thermometer FT 100 User Manual","beurer-non-contact-thermometer-ft-100-user-manual",{"title":163,"full_title":164,"slug":165},"Pelvic Floor Training Guide PT 20 PelviStrong","Setup: Beurer Pelvic Floor Training Guide PT 20 PelviStrong User Manual","beurer-pelvic-floor-training-guide-pt-20-pelvistrong-user-manual",[167,168],{"name":120,"slug":121},{"name":22,"slug":22},{"statusCode":4,"message":170,"data":171},"Found all comments!",[]]