Clipper Creek HCS-D Electric Vehicle Charging Station User Manual
Content
ClipperCreek HCS-D Electric Vehicle Charging Station Manual
Introduction
The ClipperCreek HCS-D Electric Vehicle Charging Station is a dual-port Level 2 electric vehicle supply equipment system designed to charge two plug-in electric vehicles from one installation. It is intended for homes, workplaces, fleet facilities, apartments, and other locations where shared EV charging is useful.
Using a 208–240-volt, single-phase electrical supply, the HCS-D can provide up to 32 amps continuously when configured for its maximum combined output. Its two SAE J1772 connectors support many battery-electric and plug-in hybrid vehicles equipped with the J1772 charging inlet. Charging power is managed between the two ports, allowing two vehicles to charge at the same time while helping the installation remain within its electrical capacity.
The enclosure is rated for indoor and outdoor use and uses a watertight NEMA 4 design. Its durable construction, wall- or pedestal-mounting options, long charging cables, and straightforward operation make it suitable for users who want dependable charging without a smartphone application or complicated account setup.
This manual explains HCS-D specifications, installation preparation, operating considerations, troubleshooting, and safety practices. Because electrical configurations can vary, a qualified electrician should verify the service, branch circuit, overcurrent protection, grounding, and local code requirements before installation.
ClipperCreek HCS-D Specifications and Features
- Product type: Dual-port Level 2 AC EV charging station.
- Input voltage: 208–240 VAC line-to-line, single phase.
- Input frequency: 50/60 Hz.
- Recommended circuit: Dedicated two-pole 40-amp circuit for the 32-amp continuous-output configuration.
- Maximum combined output: Up to 32 amps continuous, approximately 7.68 kW at 240 volts.
- Dual-vehicle operation: Two vehicles can connect simultaneously, with charging current shared between the ports.
- Vehicle connectors: Two SAE J1772 charging connectors.
- Cable options: Models may use 18-foot or 25-foot charging cables; confirm the cable length on the product label.
- Enclosure: NEMA Type 4 watertight housing for indoor or outdoor installation.
- Operating temperature: Approximately -22°F to 122°F (-30°C to 50°C), depending on the exact model configuration.
- Mounting: Wall or compatible pedestal mounting.
- Approximate enclosure dimensions: 19.7 inches high, 8.9 inches wide, and 5.3 inches deep.
- Connectivity: Charging is controlled locally through the EVSE and vehicle; Wi-Fi or Bluetooth pairing is not required.
How to Install and Set Up the ClipperCreek HCS-D
- Confirm the electrical plan. Verify that the supply voltage, available load, grounding, breaker rating, conductor size, and local code requirements match the exact HCS-D configuration.
- Select the mounting location. Choose a rigid wall or approved pedestal location near the parking spaces. Keep the enclosure accessible and position both cables so they cannot become a trip or vehicle hazard.
- Install the circuit. A qualified electrician should install the dedicated two-pole circuit and any required conduit, disconnecting means, and weatherproof fittings.
- Mount the EVSE. Secure the station using suitable hardware for the mounting surface. Do not rely on drywall alone or place stress on the charging cables.
- Connect power safely. For hardwired models, turn off the upstream breaker before connecting or disconnecting service conductors. Follow the exact installation instructions supplied with the unit.
- Restore power and inspect. Check that the enclosure, conduit, connectors, and cable hangers are secure. Energize the circuit and observe the station indicators.
- Begin charging. Insert a J1772 connector fully into the vehicle inlet. The vehicle normally controls charging authorization and the final charging schedule.
The HCS-D generally does not require app pairing or wireless configuration. If charging does not begin, confirm that the connector is fully seated, the vehicle is unlocked or authorized to charge, and any scheduled-charging setting is disabled. Never operate the station if the enclosure, cable, connector, or ground path appears damaged.
ClipperCreek HCS-D Troubleshooting Guide
- No indicator or no response: Check the dedicated breaker and verify that the upstream disconnect is on. If the breaker trips again, leave it off and contact a qualified electrician.
- Vehicle does not start charging: Reseat the J1772 connector until it locks. Confirm that the vehicle is in Park, charging is enabled, and a delayed-charging schedule is not active.
- Only one vehicle charges: Check both connectors and vehicle charge settings. Available current may be shared between ports, and some vehicles may temporarily pause while the station manages the load.
- Charging stops unexpectedly: Inspect the connector for moisture, dirt, heat damage, or loose fit. Allow an overheated connector or cable to cool before testing again.
- Breaker trips repeatedly: Stop using the station and have an electrician inspect circuit capacity, connections, voltage, grounding, and other loads on the circuit.
- Grounding or service fault: Do not bypass protective devices. The EVSE may prevent the contactor from closing when a valid equipment-ground connection is not detected.
- Indicator pattern is unclear: Record the visible light behavior, vehicle make and model, installation type, and serial number before contacting support. Exact indicator meanings can vary by revision.
Keep the enclosure and connectors clean, protect cables from vehicle tires, and periodically inspect mounting hardware. For service, have the model and serial number available. ClipperCreek service materials list support at (877) 694-4194, generally Monday through Friday from 8:00 a.m. to 5:00 p.m. Pacific Time. Confirm current warranty terms and support coverage with the current manufacturer documentation because warranty policies can vary by product version and purchase date.
Pros and Cons of the ClipperCreek HCS-D
Advantages
- Two charging ports: Supports shared charging for two vehicles without installing two separate wall units.
- Strong Level 2 performance: Up to 32 amps continuous output can provide substantially faster charging than a standard household outlet.
- Outdoor-ready construction: The NEMA 4 enclosure is designed for weather-resistant indoor or outdoor installation.
- Simple operation: No app, account, wireless network, or subscription is required for basic charging.
- Flexible mounting: Wall and pedestal installations can suit residential, workplace, fleet, and shared-parking layouts.
- Long cable options: Available cable lengths can make it easier to reach vehicle charge ports from a practical mounting position.
Limitations
- Electrical installation required: A dedicated high-voltage circuit and qualified installation may be necessary.
- Shared output: Two connected vehicles may not receive the full maximum current at the same time.
- No advanced connected features: Users who need Wi-Fi monitoring, remote scheduling, energy reports, or access control may prefer a smart commercial EV charger.
- J1772 compatibility: Vehicles using another inlet standard require an appropriate, approved charging solution.
- Best suited for: Owners, workplaces, and small fleets that prioritize rugged dual-port charging and simple local operation over app-based controls.
- Consider another category if: Dynamic load management, payment processing, network management, or detailed usage reporting is essential.
Safety and Maintenance Reminders
- Use the ClipperCreek HCS-D only with a properly grounded electrical supply.
- Turn off the circuit breaker before electrical work or hardwired service.
- Do not use a damaged connector, cable, enclosure, or mounting assembly.
- Keep charging connectors dry, clean, and protected when they are not in use.
- Do not use extension cords, adapters, or improvised wiring unless specifically approved for the exact installation.
- Follow the vehicle manufacturer’s charging instructions in addition to this product guide.
Faqs
How do I set up the clipper creek HCS-D Electric Vehicle Charging Station for the first time?
Can the clipper creek HCS-D Electric Vehicle Charging Station charge two electric vehicles at once?
Which electric vehicles are compatible with the clipper creek HCS-D Electric Vehicle Charging Station?
What should I do if the clipper creek HCS-D Electric Vehicle Charging Station shows a fault light?
Why is the clipper creek HCS-D Electric Vehicle Charging Station charging more slowly than expected?
What electrical requirements does the clipper creek HCS-D Electric Vehicle Charging Station need?
How should I store and handle the clipper creek HCS-D charging cables?
How do I maintain the clipper creek HCS-D Electric Vehicle Charging Station outdoors?
More clipper creek manuals
Leave a Comment