Installation: Control4 C4-V-ROSW120 Receptacle Outlet Switch User Manual

Content

Overview

The C4-V-ROSW120 Receptacle Outlet Switch is a Zigbee-enabled smart receptacle for integrating lamps and other suitable plug-in devices into a Control4 system. It provides one remotely controlled outlet and one outlet that remains continuously powered.

Use the front button for local on/off operation, or control the switched outlet through Control4 interfaces, scenes, schedules, and automations. The device is intended for indoor installations and is designed for users who want discreet control of compatible 120V loads without replacing a separate plug-in appliance controller.

Specifications

  • Model: C4-V-ROSW120
  • Product number: 43102
  • Electrical rating: 120V AC, 60 Hz
  • Wireless communication: 2.4 GHz IEEE 802.15.4 Zigbee
  • Controlled outlet maximum: 1000W incandescent, 1/2 HP motor, 1800W or 15A resistive load, or 3.75A LED/CFL
  • Combined outlet maximum: 1800W or 15A resistive load across both outlets
  • Wireless range: Up to 150 feet or 45 meters in line-of-sight conditions
  • Recommended device spacing: 15 to 30 feet or 4.5 to 9 meters for normal operation
  • Operating temperature: 32°F to 104°F or 0°C to 40°C
  • Installation type: Direct plug-in control construction
  • Control action: Type 1.B
  • Pollution degree: 2
  • Impulse voltage: 1500V
  • Use location: Indoor installations only

Detailed Description

The receptacle has two outlets with different functions. The Zigbee-controlled outlet can be switched on or off manually at the device or remotely through the Control4 Zigbee network. The always-on outlet supplies power continuously and is not affected by the controlled outlet command.

The front Manual/Program button performs local control and is also used during Zigbee identification, pairing, and reset procedures. A programmable single-color LED communicates operating and network status. While the device is being added to a Control4 project, the LED can blink during the identification process.

The connection terminals are identified as Line, Neutral, and Ground. Line is the hot conductor, Neutral is the return conductor, and Ground provides the protective earth connection. The device uses copper wiring only and has no user-serviceable parts.

After joining a Control4 Zigbee network, the switch can receive supported over-the-air updates through the Control4 controller. The device can also help extend Zigbee communication as part of the network, depending on the system configuration and placement of nearby devices.

Safety

  • Turn off power at the circuit breaker or fuse box before removing an existing receptacle or making wiring connections. Verify that power is off before touching the wiring.
  • Electrical installation should be performed by a qualified electrician when there is uncertainty about the circuit, wiring, grounding, or local requirements.
  • Use 14 AWG or larger conductors rated for at least 80°C for Line, Neutral, and Ground connections.
  • Strip wires to approximately 5/8 inch or 16 mm and tighten terminal screws to 12 lbf-in or 14 kgf-cm.
  • Use the screw terminals only with copper wire. Consult a qualified electrician if the electrical box contains aluminum wiring.
  • Do not exceed the controlled-outlet rating or the combined rating of both outlets.
  • Do not use Zigbee control for electric heaters or other appliances that could create a fire, burn, electrical shock, or other hazardous condition if switched on automatically or without supervision.
  • Never use the device to supply power to or control medical equipment or life-support equipment.
  • Keep the switch and connected equipment indoors and within the specified operating temperature range.
  • Do not modify the antenna or the device. Unauthorized changes may affect radio compliance and operating authority.

Setup and Operation

Install the receptacle

  1. Switch off the circuit at the breaker or fuse box.
  2. Confirm that the switch box is no longer energized.
  3. Remove the wallplate.
  4. Remove the screws holding the existing receptacle.
  5. Carefully pull the receptacle from the wall box and label each conductor according to its existing terminal.
  6. Connect the circuit conductors to the matching terminals on the smart receptacle: Line to the hot conductor, Neutral to the neutral conductor, and Ground to the ground conductor.
  7. Fold the conductors carefully into the electrical box without pinching or crushing them.
  8. Secure the receptacle to the box with the supplied screws.
  9. Install a compatible one-gang wallplate. A Control4 one-gang faceplate, Contemporary one-gang Essential faceplate, or Decora-sized faceplate can be used.
  10. Restore power at the breaker or fuse box and test the receptacle.

Add the switch to Control4

Integration requires Control4 OS 3.1.2 or newer and Composer access.

  1. Add the Receptacle Outlet Switch driver for C4-V-ROSW120 to the project in Composer.
  2. Open the Network > Zigbee Network view.
  3. Double-click the receptacle driver to open the identification window.
  4. Follow the on-screen identification instructions and press the device’s Manual/Program button four times quickly.
  5. Wait for the switch to join the Zigbee network. When pairing completes, the LED stops blinking and the device address appears in Composer.

The LED may blink slowly while the switch has not yet been added to a Control4 project. If automatic scanning times out, press the top button four times quickly to restart pairing. If Composer requests an install code, enter the complete code shown on the product’s QR-code label.

Use the outlets

  • Plug a suitable load into the Zigbee-controlled outlet when remote or scheduled on/off operation is required.
  • Use the always-on outlet for equipment that must remain powered regardless of the smart outlet state.
  • Press the front Manual/Program button to change the state of the controlled outlet locally.
  • Use the Control4 system to operate the controlled outlet remotely or include it in scenes and scheduled events.

Remove or reset the switch

To remove the device through Composer, open Network > Zigbee Network, select the Receptacle Outlet Switch, and choose Disconnect. Removing it resets its configuration parameters.

For a manual reset, press the Manual/Program button 13 times quickly using short presses. This removes the receptacle from the Zigbee network and restores its network configuration to the reset state.

Troubleshooting

The controlled outlet does not respond

  • Confirm that the circuit breaker or fuse is on.
  • Check that Line, Neutral, and Ground are connected to the correct terminals.
  • Verify that the connected appliance does not exceed the controlled-outlet rating.
  • Press the Manual/Program button to determine whether local control works.
  • Move the device or a nearby Zigbee receiver closer if the wireless signal is unreliable.

The switch will not join the Zigbee network

  • Confirm that the Control4 project uses OS 3.1.2 or newer.
  • Start identification in Composer and press the button four times quickly.
  • If the scan times out, repeat the four-press pairing sequence.
  • Check the product QR-code label if Composer requests the installation code, and enter the complete code.
  • Ensure the device is within a practical range of the nearest Zigbee receiver.

The LED continues blinking

A slowly blinking LED can indicate that the switch has not yet been added to a Control4 project. Complete the Composer identification process and wait for the device to appear on the Zigbee network.

The appliance switches on unexpectedly

Review Control4 schedules, scenes, and automated events. Zigbee devices can respond to programmed events even when no one is in the room. Do not connect appliances that could create a dangerous condition if activated automatically.

Pros & Cons

  • Pros: Provides one controlled and one always-on outlet in a single receptacle.
  • Pros: Supports local button control and remote Control4 Zigbee operation.
  • Pros: Offers scheduled and scene-based control after integration with a compatible Control4 system.
  • Pros: Supports several common lighting, resistive, motor, LED, and CFL load categories within the stated limits.
  • Cons: Installation requires work inside an electrical box and may require a qualified electrician.
  • Cons: The controlled outlet cannot be used for medical equipment, life-support equipment, electric heaters, or other hazardous automatically activated loads.
  • Cons: Wireless performance depends on Zigbee network placement, distance, and building conditions.

PDF

Faqs

How do I install the C4-V-ROSW120 Receptacle Outlet Switch safely?

Turn off power at the circuit breaker or fuse box, then verify that the receptacle box is not energized. Remove the wallplate and existing outlet, label each wire by its original terminal, and connect the new switch to LINE, NEUTRAL, and GROUND. Use copper wire only, with 14 AWG or larger conductors rated for at least 80°C. Keep the recommended 5/8-inch wire strip length, avoid pinching wires, secure the receptacle, install the wallplate, and restore power only after checking every connection.

Which outlet on the C4-V-ROSW120 is controlled by Zigbee?

The C4-V-ROSW120 has two receptacles with different functions. One outlet remains always on for equipment that should have continuous power. The second outlet is Zigbee-controlled and can be switched manually using the front Manual/Program button or remotely through a Control4 system. Check the outlet markings and connect the intended device to the controllable receptacle. Do not assume both outlets respond to remote commands, because the always-on outlet is not switched.

What load limits apply to the C4-V-ROSW120 controlled outlet?

Do not exceed the rating for the device connected to the Zigbee-controlled outlet: 1000W for incandescent lighting, 1/2 horsepower for a motor, 1800W or 15A for a resistive load, or 3.75A for LED or CFL loads. The combined load connected to both outlets must remain within 1800W or 15A resistive. Confirm the appliance label before connecting it, and avoid equipment that could become dangerous if switched on automatically.

How do I pair the C4-V-ROSW120 with a Control4 Zigbee network?

The receptacle requires Control4 OS 3.1.2 or newer. Add the C4-V-ROSW120 driver to the project, open the Zigbee Network view in Composer, and begin identification. When prompted, press the device’s Manual/Program button four times. A slowly blinking LED indicates the switch is not yet added to a project; after successful pairing, the blinking stops and the device address appears in Composer. Keep the switch near the Zigbee network during setup.

What should I do if Zigbee pairing times out?

If the C4-V-ROSW120 does not join the Control4 Zigbee network, wait for the identification process to time out, then restart pairing by pressing the top Manual/Program button four times quickly. Make sure the outlet has power and is within a practical distance of the nearest Zigbee receiver. If the system requests an install code, use the complete code printed on the product label rather than entering only part of it.

How can I reset and remove the C4-V-ROSW120 from Zigbee?

To remove the receptacle through Composer, open Network > Zigbee Network, select the C4-V-ROSW120, and choose Disconnect. This removes it from the Zigbee network and resets its configuration parameters. A manual reset is also available: press the Manual/Program button 13 times quickly using short presses. After resetting, the outlet must be identified and added again before Control4 programming or remote control will work.

Why is the C4-V-ROSW120 not responding to remote commands?

First, confirm that the appliance is plugged into the Zigbee-controlled outlet rather than the always-on outlet. Check that the receptacle has power, the circuit breaker has not tripped, and the switch is still identified in the Control4 project. Zigbee range can be affected by walls and other obstructions; normal placement is approximately 15 to 30 feet from another device, while the stated line-of-sight range is up to 150 feet. Re-pair the switch if its network connection was lost.

What appliances should not be controlled with this Zigbee receptacle?

Do not use the C4-V-ROSW120 to control electric heaters or appliances that could create a hazardous condition when turned on automatically, unexpectedly, or without supervision. Avoid connecting medical or life-support equipment, because Zigbee devices must never supply power to or control those systems. Remember that schedules, scenes, or an accidental remote-button press can activate the outlet while nobody is nearby. Use the receptacle only with equipment suitable for remote on/off control.