Introduction
The Cooper Lighting Solutions SEL series offers robust emergency lighting solutions designed to provide reliable illumination during power outages. Featuring higher power heads, these lights ensure optimal egress coverage ranging from 32 to 78 feet, with a total system coverage of 193 feet when using remote-capable versions. The long-life LED source and sealed nickel-cadmium battery guarantee performance for a minimum of 90 minutes. Priced at approximately $150, they are ideal for commercial and industrial applications.
Specifications
- Emergency Lighting Mode: Automatically switches to battery power in case of a power outage.
- Battery Life: Up to 90 minutes of continuous illumination during an emergency.
- Lumen Output: Provides 10-15 lumens per LED, ensuring bright and clear lighting.
- Compliance: Meets or exceeds UL 924 and NFPA 101 standards for emergency lighting.
- Mounting Options: Wall mount, ceiling mount, and universal mounting brackets available.
- LED Life Expectancy: Up to 25,000 hours of LED life.
Description
The Cooper Lighting Solutions Sure-Lites SEL ADX142857 is a robust and reliable emergency lighting fixture. It features high-efficiency LEDs that provide clear and bright illumination, ensuring that exit routes and pathways are visible during emergencies. The unit includes a rechargeable battery that automatically charges when connected to a power source, ensuring it is always ready for use. The compact and sleek design makes it easy to install in various settings without compromising aesthetics.
This product is built with durability in mind, using high-quality materials that withstand the rigors of daily use and potential environmental hazards. The Sure-Lites SEL ADX142857 is an excellent choice for businesses looking to enhance their emergency preparedness and compliance with safety regulations.
WARNING
Risk of Fire/Electric Shock
If not qualified, consult an electrician.
WARNING
Risk of Electric Shock
Disconnect power at fuse or circuit breaker before installing or servicing.
Important Safeguards
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING.
- READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- Do not use outdoors.
- Do not use in hazardous locations, or near gas or electric heaters.
- Do not let power supply cords touch hot surfaces.
- Use caution when servicing batteries. Battery acid can cause burns to the skin and eyes. If acid is spilled on the skin or in the eyes, flush the acid with fresh water and contact a physician immediately.
- Do not use this equipment for other than the intended use.
- Installation is to be performed only by qualified personnel.
- Install in accordance with the National Electric Code and local regulatory agency requirements.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
- SAVE THESE INSTRUCTIONS
MAX MOUNTING HEIGHT: 17.24 FT for SEL25 models and 25.39 FT for SEL50 models
SEL ADX142857 INSTALLATION
- De-energize the circuit at the junction box (J-box) where the emergency light is to be installed.
- Open the emergency light by inserting a screwdriver in the two slots at the bottom of the unit, then tipping the cover-up off of the backplate.
- To mount to a junction box - Drill out the appropriate mounting pattern and the wire pass hole in the backplate to fit the J-box being used.
- To mount to conduit – Cut out the U-shaped knockout on the cover using snips, then attach the 1/2” conduit hub to the backplate.
Once the backplate is secured, the housing can be held in place during installation using the EZ Hang feature. (see Fig. 1)
- Connect the incoming wires to the fixture’s power supply wires using the wire nuts provided. Connect the white wire to the neutral. If using 120V, connect the black wire to the hot lead. If using 277V, connect the orange wire to the hot lead. Cap the unused lead. Secure the emergency light to the wall and/or junction box using installer-supplied hardware.
- Connect the battery to the PCB. See the schematic for details.
- Snap the cover onto the backplate.
- Energize AC supply. The test button should illuminate, and LED heads will illuminate briefly when the test button is pushed.
- Adjust the heads as needed.
- If the fixture is to be powered down for an extended period after initial installation, replace the EZ Key. This will prevent the battery from discharging when AC power is removed. However, it will also prevent the battery from charging when AC power is restored, so it must be removed once the unit is ready for regular operation.
OPERATION
Depress the test switch. The LED heads will remain lit and the charge LED will extinguish. LED heads will illuminate as long as the button is pushed. Release the test switch. The charge LED will illuminate and the LED heads will turn off.
MAINTENANCE
None required. Replace the batteries as needed according to ambient conditions. However, we recommend that the equipment be tested regularly in accordance with local codes.
NOTE: Servicing of any parts should be performed by qualified personnel. Only use replacement parts supplied by Cooper Lighting Solutions.
CAUTION: This equipment is furnished with a sophisticated low-voltage battery dropout circuit to protect the battery from over-discharge after its useful output has been used. Allow 24-hour recharge time after installation or power failure for 90-minute testing.
Setup Guide
To operate the Cooper Lighting Solutions Sure-Lites SEL ADX142857, follow these steps:
- Install the fixture according to the provided mounting instructions. Ensure it is securely fastened to the wall or ceiling.
- Connect the power cord to a suitable electrical outlet. The battery will begin charging automatically.
- Test the fixture by simulating a power outage or using the test button located on the unit.
- Regularly inspect and maintain the fixture to ensure optimal performance.
SCHEMATIC
SEL with Base Heads
SEL with Higher Power Heads
Troubleshooting
If LED heads or charge indicator LED does not illuminate, check the following:
- Check AC supply – verify that the unit has a 24-hour AC supply.
- The unit is shorted or the battery is not connected.
- Battery discharged. Permit the unit to charge for 24 hours and then re-test.
- If following the above troubleshooting hints does not solve your problem, contact your local Cooper Lighting Solutions representative for assistance.
Cooper Lighting Solutions Warranty
Please refer to https://www.cooperlighting.com for our terms and conditions.
Pros & Cons
Pros
- High-efficiency LEDs providing bright illumination.
- Long-lasting battery life with up to 90 minutes of emergency lighting.
- Compliant with major safety standards (UL 924 and NFPA 101).
- Durable construction with long-lasting materials.
- Versatile mounting options for various environments.
Cons
- Potentially higher initial cost compared to basic emergency lighting solutions.
Customer Reviews
Customers have praised the Cooper Lighting Solutions Sure-Lites SEL ADX142857 for its reliability and brightness. Many have noted that it provides peace of mind knowing their facilities are well-equipped for emergency situations. Some common complaints include the higher initial cost and the need for occasional battery replacements.
Faqs
What is the typical lifespan of the LEDs in the Cooper Lighting Solutions?
Is the Cooper Lighting Solutions Sure-Lites compliant with major safety standards?
How long does the battery last during an emergency?
Can I install the Solutions Sure-Lites SEL myself?
What are some common issues with the Cooper Lighting SEL ADX142857?
How often should I test my SEL ADX142857?
Can I use the Cooper Lighting outdoors?
What kind of mounting options are available for the Cooper Lighting Solutions?
Leave a Comment