How to Assemble: Giandel Power Inverter PS-2000SAR User Manual
Content
Introduction of Giandel Power Inverter PS-2000SAR
The Giandel Power Inverter is a powerful and reliable solution for converting DC power to AC power. This product is ideal for those who need a stable power supply during outdoor activities, such as camping, fishing, or tailgating. With a maximum output of 2000W, this inverter can handle a variety of devices, from small electronics to power tools. The estimated price of the Giandel Power Inverter PS-2000SAR is around $200 to $250, and it is now available for purchase.
Detailed Specifications
The Power Inverter PS-2000SAR boasts the following key features
Model | PS-1500SAR | PS-2000SAR | ||
Continuous Power | 1500W | 2000W | ||
Peak Power | 3000W | 4000W | ||
Rated input Voltage | 12VDC | 24VDC | 12VDC | 24VDC |
Input Voltage Range | 9.5~16VDC | 19~32VDC | 9.5~16VDC | 19~32VDC |
Over Voltage Shutdown | 16VDC | 32VDC | 16VDC | 32VDC |
Low Voltage Shutdown | 9.5VDC | 19VDC | 9.5VDC | 19VDC |
Low VoltageAlarm | 9.8VDC | 19.6VDC | 9.8VDC | 19.6VDC |
Output Voltage | 110~120V / 220V ~240V ±10% (Be subjected to the rating) | |||
Frequency | 50Hz / 60Hz ±1Hz (Refer to label) | |||
Wave form | Pure Sine Wave | |||
Efficiency | About 90% | |||
Over heat Protection | 149±41°F | |||
Over load protection | 1500~1700W | 2000~2400W | ||
Short Circuit protection | YES | |||
Display | LCD | |||
USB | 5VDC,Max2.4A×2 | |||
No load current | 1.2A | 0.7A | 1.5A | 0.9A |
Cooling fan | The cooling fan won't workuntil inverter casereach about 104°F or load exceeds 40% of ratingpower。 | |||
Operating temperature | 32 ~ 104°F | |||
Storage temperature | 14 ~ 113°F | |||
Size (L×W×H) | 443×203×100mm | 443×203×100mm | ||
Weight | 4.5Kg | 4.98Kg |
- Maximum output power: 2000W
- Continuous output power: 1600W
- Peak power: 4000W
- Input voltage: 12V
- Output voltage: 110V/120V
- Conversion efficiency: 90%
- Protection features: Overload protection, overvoltage protection, and low voltage protection
- Cooling system: Forced ventilation
- Weight: 8.6 lbs
- Dimensions: 14.6 x 6.3 x 4.1 inches
Description of Giandel Power Inverter
The Power Inverter PS-2000SAR is a high-quality power inverter that provides a stable and reliable power supply for a variety of devices. This product is made with durable materials, ensuring a long lifespan and reliable performance. The inverter features a forced ventilation system that ensures efficient cooling and prevents overheating. The protection features, such as overload protection, overvoltage protection, and low voltage protection, ensure safe operation and protect your devices from damage. The Giandel Power Inverter PS-2000SAR is easy to use, with a simple and user-friendly interface, making it ideal for both personal and professional use.
BRIEF
GIANDEL power inverter is an advanced tool of power conversion, and it can supply you with AC power converted from DC power source. Not only can be used in cars, vessels and camping, but also can be used in emergency when out of electricity.
In order to use the inverter efficiently and safely, please install and use it in a proper way. Please read the instruction carefully before installing and using the appliance.
WARNING AND SAFETY
- Read the manual before connecting this inverter and keep it for future reference.
- While opening the product package, please check the integrity of the product and accessories. If there is any problem, please do not use it.
- While connecting and using for the first time, if there is smoke or explosion sound in the product, please stop using immediately and disconnect the product from the battery and electrical appliances. This may be caused by damage during the transportation or due to moisture during storage in the warehouse before delivery. Please contact your seller in time.
- During daily use, if there is smoke or explosion sound in the product, please don't worry, this is due to the internal fuse protection of the product. Please do not disassemble it by yourself. Please stop using the product immediately. Disconnect the product from the battery and electrical appliances. Contact the seller in time and only with seller's agreement a hired professional personnel can disassemble the product. Otherwise, it may cause electric shock, fire and serious personal injury.
- Do not put the inverter under direct sun light or near a heating source.
- The case of inverter will get hot during using. Do not allow flammable materials such as clothing, sleeping bags, carpet or any other flammable materials to touch the inverter. The heat from the inverter can damage these items.
The power inverter is designed to be used with a negative ground electrical system!Don't use with positive ground electrical systems (the majority of modern automobiles, RVs, trucks and boats are negative ground). - Do not disassemble the unit randomly: it may cause fire or electric shock.
- Do not connect the negative to car chassis when use in car.
- This device should only be serviced by a qualified technician. This item does not have any serviceable parts.
- Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures during installation.
- Do not operate the inverter if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, do not operate the inverter.
- People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a pacemaker could cause interference to or failure of the pacemaker.
- Keep the inverter well-ventilated.
- Do not place any objects on top of or next to the inverter or allow anything to cover the cooling fans; the inverter will overheat, causing a potential fire hazard and/or damage to the inverter. Leave adequate ventilation space underneath the inverter as well; thick carpets or rugs can obstruct air flow, causing the inverter to overheat.
- Avoid unintentional starting. Be sure the switch is in the OFF position when not in use and before plugging in any appliance. Disconnect the battery and inverter when not in use for a long time.
- Keep the inverter away from children. Don't install the inverter where it is accessible to children.
- The power inverter will output the same AC power as utility power, please treat the AC outlets as carefully as you would your home AC outlets. Do not put anything other than an electrical appliance into the output terminal. It may cause shock or fire.
- This product cannot be used for medical and life support equipment.
PARTS LIST of Power Inverter PS-2000SAR
DC Input Side
AC Output side
Remote controller box
Setup Guide
To set up the Giandel Power Inverter follow these steps
- Connect the inverter to a 12V DC power source, such as a car battery or a power bank.
- Plug your devices into the inverter's AC outlets or USB ports.
- Turn on the inverter and adjust the power output as needed.
- Monitor the inverter's operation and ensure it's working properly.
ASSEMBLE OF PS-2000SAR
- The position of mounting
First ensure that there is enough space to install the inverter, while the installation location must meet the following requirements:- Drying: Do not use water or other liquids dripping on the inverter.
- Cool: a working environment temperature of the product is 32 ~104°F, preferably a temperature of 50~77°F, at a temperature as low as possible within this range.
- Ventilation: There should be a certain distance between inverter and other objects, to avoid blocking the products vents.
- Clean: Do not install the products in the dusty, wood chips or other particles. If cooling fan is on, the particles involved in the inside of the product, thus affecting the normal work.
- Inverters and batteries when connected, will produce arcs or sparks, so there should not be around flammable objects such as gasoline, alcohol, etc.
- Assemble the inverter
For this big power inverter, which has a heavier weight, preferably mount it on a
solid platform, such as floor, table or mounting bracket fine. In order to avoid falling off, platform for supporting the product should can bear the weight of sufficient capacity, and it is good with four screws to secure the product.
Assemble the remote controller box
- Fix the remote box on flat surface (No need a hole ), and use 2 screws to fix it through the two mounting holes on the remote controller.
- Also, it is available to fix on a 86*86mm standard Electrical box.
- Connect the remote box and inverter with the wire.
Note: In case not connect to the remote controller, the inverter can be also used as a normal pure sine wave inverter, turned on by the power switch on the item.
BATTERY
- Current and voltage
The battery is designed to supply the unit with DC input voltage and the rated voltage should be in accordance with the rated input voltage of the inverter. Any voltage exceeds the range of the input voltage of the inverter will cause over voltage or under voltage protection. In the meantime, the battery should supply sufficient current. The small capacity battery cannot drive the large power electrical appliance. In this case, the battery will be in under voltage protection because of the over-discharge of the battery. The simple calculation method of battery current is: load power divided by battery voltage. Due to the consumption of the inverter itself, the actual current will be about 10% larger. For example, the voltage of battery is 12VDC, and load power is 1000W, therefore, the actual current of the battery is about 1000W÷12V×110%≈91.6A. - Battery operating time
Battery operating time depends on battery capacity and current, and the calculation formula of operating time is: battery capacity÷current=battery capacity÷(the load power÷battery voltage×110%). For example, battery specification is 12V, 2000Ah, load power is 1000W, so the total discharging time is 2000Ah÷(1000÷12×110%)≈21.8 hours. Note: The result of formula above is on the basic of discharging rate of 20 hours of the battery, that is, the result is from the discharging current of 2000Ah battery not exceed 100A. When the charging current exceeds this value, the discharging period will reduce. And the quantity of the electricity of the battery may also influence the result. Please refer to the specification of the battery manufacturer.
CONNECTION
Grounding
The power inverter has a terminal on the rear panel marked " Grounding "or " ". This is used to connect the chassis of the power inverter to the ground. The ground terminal has already connected to the ground wire of AC output receptacle through the internal connecting wire. The ground terminal must be connected to the ground wire, which depends on where the power inverter is installed. In a vehicle, connect the ground terminal to the chassis of the vehicle. In a boat, connect it to the boat's grounding systems. In a fixed location, connect the ground terminal to the earth.
Warning
- To make sure the firmness of the connection. The ground wire must be 14AWG (2.08mm2) or even larger.
- Do not operate the power inverter without connecting to the ground. Electric shock may be resulted.
Connect to the battery
- Please do all the safety precautions before connection, and then check whether the battery voltage is in accordance with the input voltage of the inverter. Only the voltage of the battery accords with the requirements can be allowed to connect with the inverter.
- The connecting wire must bear enough current. Depending on the table below, please choose the input DC wire or larger one.
Rated voltage of inverter | Current max.load power | Max. current of wire | Specification of wire length≤1m | Specification of wire length1-2m | Specification of wire length≤N m |
12V | 1200W | 100A | 6AWG (13.3mm2) | 3AWG (26.67mm2) | N×6AWG (N×13.3mm2) |
1500W | 150A | 4AWG(21.15mm2) | 1AWG(42.41mm2) | N×4AWG (N×21.15mm2) | |
2000W | 200A | 3AWG(26.67mm2) | 0AWG(53.49mm2) | N×3AWG(N×26.67mm2) | |
2500W | 250A | 2AWG(33.62mm2) | 00AWG(67.43mm2) | N×2AWG(N×33.62mm2) | |
3000W | 300A | 1AWG(42.41mm2) | 000AWG (85.01mm2) | N×1AWG(N×42.41mm2) | |
24V | 1200W | 50A | 9AWG(6.63mm2) | 6AWG(13.3mm2) | N×9AWG(N×6.63mm2) |
1500W | 75A | 7AWG(10.55mm2) | 4AWG(21.15mm2) | N×7AWG(N×10.55mm2) | |
2000W | 100A | 6AWG(13.3mm2) | 3AWG(26.67mm2) | N×6AWG(N×13.3mm2) | |
2500W | 125A | 5AWG(16.77mm2) | 2AWG(33.62mm2) | N×5AWG(N×16.77mm2) | |
3000W | 150A | 4AWG(21.15mm2) | 1AWG(42.41mm2) | N×4AWG(N×21.15mm2) |
Note
- The table above is only for your reference. In practice, the thick wire can be replaced by two thin parallel wires if only the total cross-sectional area of the wire meets the requirements.
- In high current, the input DC wire may produce voltage drop, therefore, the operating voltage should be subject to the value on the terminals. If the voltage drop is too large, you can increase the cross-sectional area or reduce the length of the lead.
- Connect cathode wire of the battery to the cathode terminal (black) on the rear panel of inverter and then connect the anode wire of the battery to the anode terminal (red) on the inverter, and fix them.
Warning
- Please wear eye patch and work clothes when working around the battery to protect your eyes and skin from the acid and corrosive objects.
- Prepare enough water and soap. In case the acid material splashes on your skin, clean it by soap and water as soon as possible. If the acid material spays to your eyes accidentally, clean it by cold water and then sent to hospital.
- Do not put any combustible material in the location of installation for it will result in spark when connected to the battery.
- Keep good ventilation. The battery may produce a little inflammable gas when it works, so keep away from the inverter and it is better to install them in different space.
- Fix the connecting wire of the input DC, or it will result in the over-reduction of the voltage or over-temperature of the inverter.
- Reverse connection of the polarities or the short circuit will burn the fuse or result in the permanent damage of the internal elements of inverter.
- Take away the metal accouterments, such as ring or watch, when installation, to avoid the short circuit.
- Although there is over-voltage protection, it may also cause damage of the inverter if the input voltage is too high.
Connection of the AC appliance
Put the load power plug of the AC appliance into the output AC receptacle of the inverter directly.
Warning
- Make sure that the switches of the inverter and appliance power are in OFF position before connection.
- Check the power cord. If it is damaged, it should be connected after replacement.
- Each outlet of the inverter has a given current rating of the manufacturer. It shall not exceed this value during use. Otherwise, the socket may be damaged by overheating and may cause an electric shock. The maximum output power of a single socket is shown in the following table
Connection of big load
For the appliances with a load more than the limit of AC socket, please connect to the Hard Wire Terminals (if have), and make sure the ground terminal of inverter connected with ground terminal of appliance.
USAGE OF Giandel PS-2000SAR
1) How to use inverter
- Check the output voltage and capacity of the battery to make sure it is in accord with the requirements of the product.
- Connect the battery and the DC cable of the inverter to ensure that the polarities are not connected reversely and in tight connection.
- Long press the switch or the remote of inverter for over 0.5s and then stop, if the indicator light on the inverter or on the remote control box is on, it means the inverter starts to work normally. This opening method can avoid turning on the unit by mistakes due to the interference or any factors.
- Switch off electrical appliances and put its plug to the AC output socket of inverter. Then switch on electrical appliance.
- The cooling fans inside the inverter do not work until the case temperature rises up to about 104°F or the load power is more than 40% of rating power.
- Switch off inverter and remote to stop working. At that time, the indicator lights in. Both inverter and remote controller are off. The inverter does not consume current of the battery when it is switched off.
How to use USB power supply
This model with USB output, can provide stable voltage 5VDC, maximum current 2.4A directly for the portable device with USB port.
Note: Before using the USB power supply, please make sure the device can be charged by USB and the maximum working current is no more than 2.4A.
SOFT START TECHNOLOGY
The soft start technology built into this inverter protects the unit from delivering too much AC power at once by gradually increasing the AC voltage pushed out. To make sure that you are utilizing this feature, turn on the appliance being used before turning on the inverter. This is especially necessary for equipment that has an inductive load or electrical motor.
OUTPUT WAVEFORM
The output wave form of this inverter is Pure Sine Wave, which is much like the one from utility-supplied AC electricity, even more purer; pure sine wave is applicable in most of loads, including electrical equipments, such as Linear Adaptor, switching power supply, transformer, and motor and so on. Comparing with Modified wave form, for inductive loads such as refrigerator and electric fans, pure sine wave form can improve its power factor and the battery's efficiency and reduce working noises effectively from appliances. For capacitive loads such as adapter of lap-top, pure sine wave can lower the rush current at work and reduce interferences to increase reliability and prolong the life of the product.
WORK INSTRUCTIONS
When item is working, the LCD display on inverter and remote controller will show battery status, input voltage, and output wattage. When item goes into protection, the LCD display on inverter and remote controller will show the following code
- Warning Sign and IN: LOW is on: Input Low Voltage Protection
- Warning Sign and IN: HIGH is on: Input High Voltage Protection
- Warning Sign and OVERLOAD is on: Overload Protection or Short-Circuit Protection
- Warning Sign and Thermometer Sign is on: Overheat Protection
PROTECTION FUNCTION
- Input Under-Voltage Alarm: When the input DC voltage is lower than 9.8V /19.6V, the buzzer will whistle intermittently to remind that the inverter will go into the under voltage protection.
- Under Voltage Protection: The inverter will automatically shut down when the input DC voltage is lower than 9.5V/19V. The buzzer will whistle continuously and the green light is off, red light is on. Please turn off the inverter and use it after recharging the battery.
- Over Voltage Protection: The inverter will automatically shut down when the input DC voltage is higher than 16V/32V. The buzzer will whistle continuously and the green light is off, red light is on. Please turn off the inverter and adjust the input voltage to the admissible range.
- Overload Protection: The inverter will automatically shut down when the load is higher than the rated power. The buzzer will whistle continuously. Turn off the inverter and resume to normal operation after taking away the excessive load
- Short-Circuit Protection: The AC output will be automatically shut down when short circuited. It will automatically reset after the problem is solved
- Thermal Protection: The unit will get hot during operation. If the temperature is higher than 149°F, the inverter will automatically shut down. Then the buzzer will whistle continuously and the green light is off, red light is on. Please turn off the inverter, and continue using it after the temperature goes back to normal naturally. Meanwhile find out the factors causing the fault, such as ventilation, ambient temperature, vent, load power etc. It can avoid similar things from happening again.
Troubleshooting
If you experience any problems with the Power Inverter PS-2000SAR, try the following solutions
- Check the power source and ensure it's providing sufficient power.
- Ensure the inverter is properly connected to the power source.
- Check the load and ensure it's not too heavy for the inverter to handle.
- Reset the inverter by turning it off and on again.
- Check the wiring and ensure there are no loose connections.
Problem | Reason | Solutions |
No output voltage, buzzer whistles continuously | Low Input DC Voltage | Low Input DC Voltage |
High Input DC Voltage |
| |
Overload | Reduce the load power | |
Over temperature |
blocking the vent and improve the ventilation condition. | |
No AC output voltage? |
1.The power switch is off. 2.Poor contact with battery. |
|
Output voltage below 100 V AC? | “True RMS”voltage meter is required to properly measure output voltage of modified waveinverter |
|
Cannot drive the load? |
|
|
Tester indicated "Open Ground"? | This is because it is not connected to a"true Earth ground ", meaning itis not connected to a metal rod stuck in the Earth. it would be impossible to do so in a boat or car while moving. The power inverter DOES NOT and cannot create atrue Earth ground on its own. |
|
Starting alarm? | The main reason is that ths instantaneous current is too large, which leads to the detection of low voltage and trigger under-voltage alarm. |
Please restart the inverter several times. |
Got 40V or so while testing inverter's ground wire and zero line? |
This voltage has no meaning, zero line can be ground. |
This is normal, there is no current leakage. |
If the unit still doesn't work normally after using all the methods above, it maybe the internal faults of the circuit. Please contact seller for warranty
Pros & Cons of Giandel Power Inverter PS-2000SAR
Pros
- High power output
- Protection features
- Forced ventilation system
- Simple and user-friendly interface
- Durable materials
Cons
- May be too heavy for some users
- May produce noise during operation
- May not be suitable for very heavy loads
- May be more expensive than some other inverters on the market
Customer Reviews of Power Inverter
Customers have praised the Power Inverter PS-2000SAR for its high power output, protection features, and forced ventilation system. Some common complaints include the weight of the inverter, the noise during operation, and the high price. Overall, customers have found the inverter to be reliable and durable, with a long lifespan and stable performance. Many have also appreciated the user-friendly interface and the sturdy construction of the inverter.
Faqs
Why Won't My PS-2000SAR Giandel Power Inverter Turn On?
Can I Charge My Car's Battery and Use the Giandel PS-2000SAR Inverter at the Same Time?
How Do I Attach the Giandel PS-2000SAR to the Remote Control?
What Upkeep Is Necessary for the Giandel PS-2000SAR?
How Can the Giandel PS-2000SAR Display's Error Codes Be Handled?
Which Safety Features Are Included in the Giandel PS-2000SAR?
Is it Possible to Use a Solar Panel System with the Giandel PS-2000SAR?
Can I Change the Giandel PS-2000SAR's Fuses on My Own?
When Not in Use, How Should I Store My Giandel PS-2000SAR?
How Do I File a Giandel PS-2000SAR Warranty Claim?
Leave a Comment