Kohler RITE-TEMP Pressure Balancing Valve K-11748 | Specs & Features
Content
Introduction of Balancing Valve K-11748
The Kohler RITE-TEMP Pressure Balancing Valve K-11748 is a high-quality plumbing valve designed to ensure consistent water temperature and pressure in showers and bathtubs. This valve offers a reliable solution for maintaining a comfortable and safe water temperature, even when there are fluctuations in the water supply. The estimated price for the K-11748 is around $120 to $150, and it has been available on the market since 2018.
Detailed Specifications
The K-11748 features a pressure balancing design that maintains water temperature within ±3°F (±1.6°C) of the set point. It has a maximum flow rate of 8 gallons per minute (gpm) at 45 psi. The valve body is made of solid brass, ensuring durability and longevity. Moreover, it is certified to meet ASME A112.18.1/CSA B125.1 standards, ensuring its compliance with industry safety and performance requirements.
Rite-Temp pressure-balancing single-control valve shall feature a brass valve body. Valve shall feature mixing valve cycles from ″cold″ to ″hot″ and a high-temperature limit setting for added safety. Valve shall feature a Rite-Temp pressure-balancing diaphragm design and a pressure-balancing mechanism of one-piece diaphragm cartridge design for ease of maintenance. Valve shall have integral diverter mechanism. Valve shall be available with or without screwdriver stops. Valve shall be designed for showerhead and hand shower applications.
Models
Kohler RITE-TEMP Pressure Features
- Brass valve bodies
- Rite-Temp pressure-balancing diaphragm design
- Pressure-balancing mechanism of one-piece diaphragm cartridge design for ease of maintenance
- Mixing valve cycles from ″cold″ to ″hot″
- Integral diverter mechanism
- High-temperature limit setting for added safety
- Available with or without screwdriver stops
- Designed for showerhead and hand shower applications
Codes/Standards Applicable
Specified model meets or exceeds the following:
- ASME A112.18.1/CSA B125.1
- ASSE 1016
Colors/Finishes
- NA: None applicable
Specified Model
Model | Description | Colors/Finishes |
---|---|---|
K-11748-K | Pressure-balancing valve without screwdriver stops | NA |
K-11748-KS | Pressure-balancing valve with screwdriver stops | NA |
Installation of Kohler RITE-TEMP Pressure Balancing Valve K-11748
Avoid cross-flow conditions. Do not install shut-off device on either valve outlet.
Description
The Kohler RITE-TEMP Pressure Balancing Valve K-11748 is an essential component for creating a safe and relaxing showering experience. It offers precise temperature control and protects users from sudden temperature fluctuations, which can be hazardous for young children, elderly individuals, or individuals with sensitive skin. The valve is designed for easy installation and maintenance, ensuring a trouble-free user experience. The sleek and modern design of the K-11748 matches Kohler's contemporary faucet collections, harmonizing seamlessly with modern bathroom decors.
Kohler Setup Guide
To install the Kohler RITE-TEMP Pressure Balancing Valve K-11748, follow these steps:
- Turn off the water supply to the shower or bathtub and drain any remaining water from the pipes.
- Remove the existing valve, if present, and clean the surrounding area.
- Install a new copper or PEX pipe for the valve inlet and outlet, following local plumbing codes and manufacturer installation guidelines.
- Wrap plumbing tape around the threads of the valve inlet and outlet, ensuring a secure seal.
- Slide the valve body into the opening and tighten the mounting screws to secure it in place.
- Connect the hot and cold water supply lines to the valve inlet and outlet.
- Install the trim by attaching the handle and temperature control to the valve body.
- Turn the water supply back on and test the valve for leaks and proper operation.
Troubleshooting of Kohler RITE-TEMP
If the valve is not functioning correctly, consider the following solutions:
- Ensure that the water supply is turned on and the valve is open.
- Check for leaks around the valve body, supply lines, and trim.
- Examine the pressure balance cartridge for debris or damage, and clean or replace as necessary.
- Confirm that the water pressure is within the recommended range (20-80 psi).
- Consult the Kohler support team if the issue persists.
Pros & Cons
Pros
- Precise temperature control
- Protection against sudden temperature fluctuations
- Durable and reliable construction
- Modern and sleek design
- Easy installation and maintenance
Cons
- Limited compatibility with some showerheads and faucets
- May require professional installation in some cases
Kohler Customer Reviews
Customers have praised the Kohler RITE-TEMP Pressure Balancing Valve K-11748 for its excellent temperature control, reliability, and sleek design. They appreciate its ability to maintain consistent water temperatures and prevent sudden hot or cold temperature fluctuations. However, some users have reported compatibility issues with certain showerheads and faucets, requiring additional adapters. Overall, the K-11748 has received positive feedback, with many users recommending it to others looking for a high-quality pressure balancing valve.
Faqs
What is a Kohler RITE-TEMP Pressure Balancing Valve K-11748?
How do I adjust the temperature limit on the Kohler RITE-TEMP Pressure Balancing Valve K-11748?
What are the installation requirements for the Kohler RITE-TEMP Pressure Balancing Valve K-11748?
Can I install the Kohler RITE-TEMP Pressure Balancing Valve K-11748 myself, or do I need a professional plumber?
Will the Kohler RITE-TEMP Pressure Balancing Valve K-11748 work with any showerhead or faucet?
How do I clean the pressure balance cartridge in the Kohler RITE-TEMP Pressure Balancing Valve K-11748?
How do I adjust the temperature on my Kohler RITE-TEMP Pressure Balancing Valve K-11748?
How often should I perform maintenance on the Kohler RITE-TEMP Pressure Balancing Valve K-11748?
How do I know if the Kohler RITE-TEMP Pressure Balancing Valve K-11748 is installed correctly?
What is the warranty period for the Kohler RITE-TEMP Pressure Balancing Valve K-11748?
Leave a Comment