The Pyle USA SereneLife Portable Air Conditioner Fan SLPAC8 is a compact and efficient cooling unit designed for small spaces, offering 8,000 BTUs of cooling power. This versatile air conditioner features three operational modes: cooling, dehumidifying, and fan, making it suitable for various climate control needs. Its lightweight design and included window mount kit ensure easy installation and mobility. The unit is priced at approximately $487.99, providing an effective solution for personal comfort during warmer months.
Specifications
- Cooling Capacity: 8,000 BTU
- Room Size Coverage: Up to 250 sq. ft.
- Power Consumption: 900W
- Noise Level: 52 dB
- Dehumidifying Capacity: 30 pints per day
- Refrigerant Type: R410A
- Dimensions: 11.5 x 13.5 x 27.5 inches
- Weight: Approximately 50 lbs
- Remote Control Included: Yes
- Washable Filter: Yes
MAIN PARTS AND COMPONENTS
- Handle
- Control panel
- Louver
- Caster
- Air outlet
- Air inlet
- Drainage nozzle
- Remote controller
- Exhaust duct assembly
- Window sealing plate assembly
Control Panel
Remote Controller
- Power key
Press the key to turn ON/OFF the A/C. - Mode key
Press the key to choose cool, fan and dry. - Temperature/ time adjusting key
Press the key at cooling mode to increase/reduce the setting temperature; press it at timing mode to adjust time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature. - Speed key
Press the key to choose high/ low spee d. - Timer key
Press the key at standby mode to set ON time. Press this key at ON mode to set OFF time. - Temperature/ Time Display Window Displays the adjusted temperature and time
- The remote controller receiving window used to receive signal of the remote controller.
- °C/°F switching key
Press the key to switch °C and °F - Sleep key
In the cooling mode, the sleep mode can be selected by this key
Description
The Serenelife SLPAC8 is designed with user convenience in mind. It features a simple and intuitive control panel along with a remote control, allowing you to adjust settings from across the room. The unit comes with a washable filter that can be easily cleaned and reused, reducing maintenance costs and extending the lifespan of the device.
The compact and lightweight design makes it easy to move the air conditioner from one room to another using the built-in wheels. The unit also includes a window kit for easy installation and venting, ensuring that hot air is efficiently expelled outside.
Product Operation
Placement and Installation
Pyle USA SereneLife Portable Air Conditioner Fan SLPAC8 Placement
- Place it at even and dry place, and keep it at least 50cm away from its surrounding object.
Installation
Screw the exhaust duct assembly in the air outlet behind the panel (counterclockwise).
Insert the air exhaust hose into the window sealing plate, adjust opening width of window so that the window can match with the sealing plate properly; length of the sealing plate is adjustable.
Incorrect Installation
- It’s important to keep the exhaust duct smooth. Incorrect installation will affect work of the A/C.
- Prevent the exhaust duct from sharp bending.
Ensure air can flow smoothly in the duct.
Warning:
The exhaust duct is designed especially for this model. Don’t replace or lengthen it; otherwise, it will result in failure.
Notice:
Max. developed length of the exhaust duct is 1,500mm. It’s better to shorten it while use and keep it in horizontal position during installation.
OPERATION METHOD
Cooling Mode
- When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.
- Press Up/Down key to adjust setting temperature (16°C~30°C)(60°F~86°F).
- Press Speed key to choose High/Mid/Low speed.
Fan Mode
- When pressing mode key or choosing Fan mode by pressing the remote controller, the wind indicator lamp lights up.
- Press Speed key to choose High/Mid/Low speed.
Temperature can’t be set.
Dehumidification Mode
- When pressing mode key or choosing dehumidification mode by pressing the remote controller, the dehumidification indicator lamp lights up.
- Remove the dehumidification water wedge, insert water manifold, place the other end of the water manifold into the water vessel or drainage passage, as shown in the right figure.
- After entering the dehumidification mode, if room tempearture≥17°C (62°F), the compressor is ON.
Then control as follows:- when room temperature ≤15°C (59°F), the compressor is OFF;
- when temperature increases to room temperature≥17°C (62°F), the compressor will start again (in order to protect the compressor, it will be restarted 3min. later).
- In dehumidification mode, the fan is defaulted to run at low speed, and wind speed can’t be adjusted.
- Temperature can’t be set.
Note: When use dehumidify function, should remove exit pipe components, otherwise, it will cause worse dehumidify performance, and appear “FL” water full alarm
Sleep mode (optional function)
- Under cool mode, pressing sleep mode key on the remote controller or pressing time key and down key together on the machine, it will start sleep mode with low wind speed and can’t be adjusted. Pressing the sleep mode key again or pressing time key and down k ey together on the machine to quit the sleep mode.
- If you press the wind speed key under the sleep mode, the screen will display ”SL”
Timer Mode
- In standby state, press the Timer key to set ON time. Press Up and Down keys to set ON time (0~24H), and the timer indicator lamp lights up.
- In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (0~24H), and the timer indicator lamp lights up.
Setup Guide
To set up the Serenelife SLPAC8,
- Start by unpacking the unit and all included accessories such as the window kit, hose, and remote control.
- Place the air conditioner on a level surface and ensure it is at least 6 inches away from any walls or obstructions.
- Install the window kit according to the instructions provided.
- Connect the hose to the back of the air conditioner and attach it to the window kit.
- Plug in the unit and turn it on using the control panel or remote control.
- Adjust settings such as fan speed, cooling mode, and temperature to your preference.
Clean and Maintenance
DRAINAGE METHOD
This product is equipped with automatic water vaporization system. The condenser is cooled with the circulating of condensing water, so as to improve cooling efficiency and save energy.
If the internal vessel is full of water, the display screen will display “FL”, and the compressor stops working automatically. After power off, unscrew the water cover, pull out the water plug to drain off water, and it will become normal after being restarted.
MAINTENANCE
Notice: In order to avoid electric shock, please turn off the A/C and unplug before maintenance or repair.
CLEANING
- Unplug before cleaning.
- Wipe with soft semi-dry cloth. Don’t use chemical reagent, such as benzene, alcohol and gasoline etc; otherwise surface of the A/C and even the whole A/C will be damaged.
- Prevent water from spattering in the A/C.
FILTER SCREEN
- Wash the filter screen once every two weeks. If it is blocked by dust, efficiency of the A/C will be reduced.
- Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures.
Put the filter screen into the warm water (about 40°C or 104°F) added with neutral detergent, dry it at a shady place after cleaning.
SEASONAL CLEANING
If the A/C will not be used for a long time:
- Pull out the water plug to drain.
- Run the A/C in fan mode for 2H till the inside is dry.
- Turn off the A/C and unplug.
- Wash the filter screen and reassemble it.
- Dismantle the exhaust duct and keep it properly.
- Cover the A/C with a plastic bag and place it at a dry place.
Common Failures and Diagnosis
Intelligent Error Detection
Error-detecting code | Multi-functional defection |
E1 | Error of the coil’s temperature sensor |
E2 | Error of indoor temperature sensor |
E4 | Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature excesses 8°C or 46.4°F, the protection is released and previous working state is recovered. |
FUSE PARAMETERS
- Voltage: 250VAC
- Current: 3.15A
Troubleshooting
In case of any of the following trouble, please contact professional maintenance personnel in time.
TROUBLE | CAUSE | SOLUTION |
The A/C doesn’t work | No display | Reset circuit breaker on AC cord |
The display panel displays “FL” | Restart the A/C after power off and draining, thenit will become normal | |
Time OFF function is started | The A/C can be restarted 3 minutes after being turning off. | |
The A/C starts frequently | Direct sunlight | Draw the curtain |
Doors and windows keep open; there are lots of people or heat source in room | Close doors and windows, remove heat source | |
Filter screen is very dirty | Clean or replace it | |
Air inlet or airoutlet is blocked | Remove the stem | |
Big noiseof the A/C | The A/C is placed unevenly | Place it at evenand firm ground, avoid shaking |
The compressor doesn’t work | Its delay protection is started | Wait for 3min., turnon after temperature decreases |
Notice: When there is any abnormal to the A/C, turn it off and unplug, and then contact professional maintenance personnel.
Fan SLPAC8 Pros & Cons
Pros
- Compact Design: Easy to move and place in different rooms.
- Multifunctional: Includes air conditioning, fan, and dehumidifying modes.
- Energy Efficient: Uses less power compared to larger air conditioning units.
- User-Friendly Controls: Simple control panel and remote control for easy operation.
- Affordable Price: Priced competitively for its features and performance.
Cons
- Noise Level: Can be slightly noisy on higher fan settings.
- Room Size Limitation: Best suited for smaller to medium-sized rooms.
- Installation Effort: Requires some effort to set up the window kit and venting system.
- Maintenance Needs: Regular filter cleaning and occasional drainage issues.
Customer Reviews
Customers have generally praised the Serenelife SLPAC8 for its effectiveness in cooling small spaces. Many have appreciated its quiet operation and energy efficiency. However, some users have noted that the installation process can be a bit cumbersome and that the unit may not be as effective in larger rooms.
Common complaints
Include the noise level on higher settings and occasional issues with drainage. Despite these minor drawbacks, the overall feedback has been positive, with many users recommending this product for its value and performance.
Faqs
How do I install the window kit for the Serenelife?
What is the cooling capacity of the Air Conditioner Fan?
Can I use the SLPAC8 in a large room?
How often should I clean the filter of my Pyle USA?
What if my Serenelife leaks water?
Is the Pyle USA Serenelife SLPAC8 energy efficient?
Can I use the Portable Air Conditioner Fan as just a fan?
How loud is the Serenelife?
What type of refrigerant does the Serenelife use?
Leave a Comment