The Shinco Portable Air Conditioner SPF1-08C is a versatile cooling solution designed for small to medium spaces, effectively cooling areas up to 200 square feet. With an 8,000 BTU capacity, it features a 3-in-1 functionality that includes cooling, fan, and dehumidifying modes. The unit is easy to install and move, thanks to its compact design and built-in wheels. Priced at approximately $299.99, it offers a convenient way to stay comfortable during hot weather.
Specifications
Model No. | SPF1-08C |
Voltage | 110V~120V |
Frequency | 60Hz |
Power | 2345W |
Dimensions | Width: 14.7 in Depth: 13.5 in Height: 26.9 in Weight: 46.3 Ibs. |
Cooling Area | 200 sq. ft. |
BTU Rating | 8,000 (ASHRAE) |
Power Cord Length | 4.9 ft |
PRODUCT FEATURES
- Carrying Handle
- Control Panel
- Adjustable Front Grille
- Casters
- Exhaust Output
- Air Intake
- Moisture Drain Plug
- Remote Control
- Exhaust Duct
- Window Sealing Plate
IMPORTANT
The air conditioner unit must always be stored and transported upright, otherwise you may cause irreparable damage to the compressor. In case of doubt, we suggest that you wait for at least 24 hours before you start the air-conditioning unit.
SAFETY INFORMATION & WARNINGS
SAFETY PRECAUTIONS
Please read the Manual carefully before operating the machine:
- Read and keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this machine near water.
- Clean it only with a damp cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the machine.
- Do not attempt to modify or extend the power cord of this machine.
- Unplug this machine during lightning storms or when it will not be used for long periods of time.
- Make sure that the available AC power matches the voltage requirements of this machine.
- Do not handle the plug with wet hands. This could result in an electric shock.
- Unplug the power cord by holding the plug, never by pulling the cord.
- Do not turn the machine on or off by plugging or unplugging the power cord.
- Turn off the machine before unplugging it.
- Refer all servicing to qualified service personnel. Servicing is required when the machine has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the machine, the machine has been exposed to rain or moisture, does not operate normally, or has been dropped.
- To reduce the risk of fire or electric shock, do not expose this machine to rain, moisture, dripping, or splashing, and no objects filled with liquids should be placed on top of it.
- The batteries of the control remote should not be exposed to excessive heat such as sunshine, fire, or the like.
CAUTION: Danger of explosion if batteries are incorrectly replaced. Replace only with the same or equivalent type.
WARNING:
ELECTRIC SHOCK HAZARD
Failure to follow these instructions can result in electric shock, fire, or death.
- This unit must be properly grounded.
- Do not, under any circumstances, cut or remove the grounding plug.
- If you do not have a properly grounded AC outlet, or if there is any doubt that the outlet is not properly grounded, a qualified electrician should check the outlet and circuit and, if necessary, install a properly grounded outlet.
- This air conditioner must be plugged into a grounded 115V, 60 Hz AC outlet, protected by a 15 amp time-delay fuse or circuit breaker.
- This air conditioner must be installed in accordance with national wiring codes.
- Do not alter or modify the plug or cord of this air conditioner. If the power cord becomes worn or damaged, the cord should only be replaced by a qualified service technician using genuine replacement parts.
- Do not use an extension cord.
ELECTRICAL SAFETY
Integrated circuit breaker
For additional safety, the power cord on this air conditioner features an integrated circuit breaker. You can test and reset the circuit breaker using the buttons provided on the plug case. Consult a qualified electrician or service person if the grounding instructions are not completely understood, or if doubt exists as to whether the air conditioner is properly grounded.
The circuit breaker should be tested periodically by pressing the TEST button, then pressing the RESET button. If the TEST button does not cause the circuit breaker to trip, or if the RESET button does not stay engaged, unplug the air conditioner immediately.
Preferred grounding method
Temporary grounding
Due to potential safety hazards, we strongly discourage the use of an adapter plug. If an adapter plug must be used for a temporary connection, use only a UL-listed adapter with a minimum capacity of 120V~60Hz, 13A, and 1560W. Make sure that the large slot of the adapter is aligned with the large slot in the outlet.
Setting Up Shinco Portable Air Conditioner SPF1-08C
Before using your portable air conditioner
- Remove and store (optional) packing materials for reuse.
- Remove any shipping tape before using the air conditioner.
- Remove tape residue with liquid dish soap and a damp cloth. Do not use sharp tools, alcohol, thinners, or abrasive cleaners to remove adhesive, which could damage the finish.
Placing your air conditioner
Place the unit on a flat, dry area near a window, so you can use the hose and diffuser to connect the air conditioner to the window installation kit in order to vent the exhaust air outside. To maintain good air circulation and optimum machine performance, leave a 20 in. (50 cm) space around it.
Description
The Shinco Portable Air Conditioner SPF1-08C is designed with user convenience in mind. The sleek and modern design fits well in any home decor, and its compact size ensures it doesn’t take up too much space. The unit comes with a remote control, allowing you to adjust settings from across the room.
The SPF1-08C also includes a built-in dehumidifier, which helps remove excess moisture from the air, making your space feel cooler and more comfortable. The automatic shut-off feature ensures that the unit turns off when the desired temperature is reached or if there is an issue with the system.
Installing Your Air Conditioner
Screw the exhaust hose to the exhaust outlet on the back of your air conditioner, then screw the hose adapter to the other end of the hose.
Measure the window size.
Install the window sealing plate in the window opening, adjusting the length to fit the window opening and securing it with "Clip" (provided).
Note: The window sealing kit works with sliding windows.Usually Portable air conditioner needs to be equipped with sliding windows. We put two sealing plates in the packaging box of the machine, and the size range after connection is 94cm-127.5cm (37in-50.20in). We also have two spare parts, one short (40cm=15.75in) and one long (67.5cm=26.57in) with "Clip".
If your window size is small, just between 67.5cm-98cm (26.57in-38.58in), you can buy a piece of short board (40cm=15.75in) and then assemble it with the one-piece board with a clip;
If your window size is large and there is still a gap on the side of the window where the two sealing panels are installed, you can buy another long panel (67.5cm=26.57in), the size range after connection is 135cm-187cm(53.15in-73.62in).
If your room has a casement window, you can also buy our sealing cloth to use.
And in the packaging bag, we also prepared 4 piece of sealing plate sponges. Just adjust the sealing plate to the size of the window, then tear off the spacer paper of the sponge, and stick the sponges along the circumference of the sealing plate. It can well prevent hot air from entering room from outside, and keeping the indoor temperature cool.Insert the hose adapter into the vent panel (A), then slide the adapter until it clicks into place (B).
(Optional): Secure the venting hose to the vent adapter using the included screw.
Note: For optimum performance, make sure the venting hose is not twisted and is free of kinks. For better efficiency, shorten the hose by squeezing its sections together.
Caution: The exhaust duct is designed especially for this air conditioner. Replacing or lengthening the duct could result in damage to your unit.
Note:
When the unit is installed in a flat and dry place,50cm(19.7 in)space must be left around the unit to make the air flow smoothly. As shown in follow figure. The best installation distance is 50 cm (19.7 in)from the back of the unit body to the wall and 90 cm (35.4 in)from the air outlet to the bottom of the unit.
Note:
The ensure proper function,Do not overextend or bend the hose.Make sure that there is no obstacle around the air outlet of the exhaust hose (in the range of 500mm)in order to the exhaust system works preperly. All the illustrations in this manual are for explanation purpose only.Your air conditioner may be slightly different. The actual shape shall prevail.
USING YOUR AIR CONDITIONER
Inserting the batteries in the remote control
- Insert two AAA batteries (provided) into the remote control.
- Power button
Press this button to turn the unit on and off. - Mode button
Press this button to cycle between the 3 modes: cool (full A\C cooling with temperature setting), fan (just fan operation without any temperature setting) and dry (fan operation plus dehumidification). In dry mode, water will collect inside the unit, and must be drained by removing the plug from the bottom of the back of the unit. If the tank is full, “FL” will appear on the display to indicate that it needs to be drained. In dry mode, the unit will stay on low fan speed, and maintain a temperature of 62 degrees. - Temperature buttons
Press these buttons to increase and decrease the set temperature. Press these buttons simultaneously to switch the temperature setting between Fahrenheit and Celsius. This can also be switched by pressing the C/F button on the remote control. - Speed button
Press this button to switch between the two fan speeds, high and low. - Timer Button
Press this button to set the unit to turn off after a specified amount of time. Pressing this button while the unit is turned off will allow you to set the unit to turn on after a specified amount of time. The timer can be set anywhere between 1 and 24 hours. - Time/Temperature Display
This window displays the set temperature, or the set time while using the timer function. - Remote control sensor
Point the remote control toward this sensor when using it. - Temperature mode button
Press this button on the remote to switch between Fahrenheit and Celsius on the temperature display window. This can also be switched by pressing the temperature control buttons on the main control panel simultaneously. - Sleep button
In cooling mode, you can press this button to enter sleep mode, which will decrease the fan speed.
Setup Guide
To set up your Shinco Portable Air Conditioner SPF1-08C,
- Start by carefully unpacking the unit and all included accessories.
- Ensure the area around the air conditioner is clear to allow for proper airflow.
- Connect the exhaust hose to the back of the unit and extend it through a window using the provided window kit.
- Secure the hose with the included brackets to ensure a tight seal.
- Plug in the air conditioner and turn it on using the remote control or the control panel on the unit.
- Select your desired temperature and fan speed, and let the SPF1-08C do the rest.
CLEANING & MAINTENANCE
DRAINING THE WATER TANK
This unit is equipped with an automatic water vaporization system. The condenser is cooled through the circulation of condensing water to improve cooling efficiency and energy conservation.
If the tank is full, “FL” will appear on the display to indicate that it needs to be drained. Turn off the unit, remove the drain plug on the bottom of the back of the unit, and drain the tank until empty. Replace the plug and turn the unit back on to resume use.
MAINTENANCE
Notice: To avoid electric shock, please turn off and unplug the unit before maintenance or repair.
CLEANING
- Unplug before cleaning.
- Clean the outside of the unit with a soft, damp cloth. Do not use chemical agents such as benzene, alcohol, gasoline, etc.which can damage the unit and void your warranty.
- Prevent any water or other liquids from getting inside the unit.
DUST FILTER
Once every two weeks, remove the dust filter from the back of the unit and wash it. Neglecting to clean the dust filter may cause the unit to run poorly over time.
SEASONAL CLEANING
If you are planning on putting the unit away long-term:
- Pull the drain plug to drain any water left in the tank.
- Run fan mode for 2 hours to help dry any collected moisture within the unit.
- Turn off the unit and unplug it.
- Wash and replace the dust filter.
- Take apart the exhaust duct.
- Cover the unit and the exhaust duct pieces with something to keep dust out.
Shinco Portable Air Conditioner SPF1-08C Troubleshooting
In case of any of the following problems, please contact our customer
ISSUE | CAUSE | SOLUTION |
---|---|---|
The A/C doesn’t work | Unit is not plugged in | Plug the unit in. |
The display panel displays “FL”. | Restart the A/C after powering off and draining; then it will return to normal. | |
The timer was set, and the unit shut off. | Restart the unit 3 minutes after it automatically shuts off. | |
The A/C starts up too frequently | The unit is in direct sunlight | Move the unit out of direct sunlight. |
Too many doors/windows are open; a heat source is affecting the unit. | Close doors and windows; remove any heat sources placed too close to the A/C. | |
Dust filter is dirty | Clean the dust filter. | |
Air intake or exhaust output are clogged. | Remove the exhaust tube and check for any blockage. | |
The unit is making too much noise | The unit isn’t placed on a level surface | Place it on an even and firm ground; avoid shaking. |
Notice: For any issues not listed here that arise while using the A/C, turn the unit off and unplug it, wait a few minutes, and try again. If problems persist, contact customer service.
ERROR CODE
CODE | DESCRIPTION |
FL | The internal water tankis full andneeds to be emptied. |
E1 | Coiltemperature sensor error.Turn off yourair conditioner and |
E2 | Indoor temperature sensorerror. Turn offyour air conditioner and call a professional maintenance technician or service center. |
E4 | Anti-freezing protection. The air conditioner coil temperature is too |
Warranty
Shinco Portable Air Conditioner SPF1-08C provides a one-year warranty.
Pros & Cons
Pros
- Compact and lightweight design for easy mobility
- Efficient cooling with multiple fan speeds
- Dehumidifying function to remove excess moisture
- Remote control for convenient operation
- 24-hour timer and auto shut-off for energy efficiency
- Quiet operation with noise levels under 52 dB
Cons
- Limited cooling capacity suitable only for small to medium-sized rooms
- Requires regular maintenance of air filters and exhaust hose
- May not be as energy-efficient as central air conditioning systems
- Some users report minor issues with the remote control range
SPF1-08C Customer Reviews
Customers generally praise the Portable Air Conditioner for its ease of use, efficient cooling, and quiet operation. However, some users have noted that the unit may not perform as well in larger spaces or during extremely hot weather.
A common complaint is the need for frequent emptying of the dehumidifier tank, especially in humid climates. Despite these minor issues, the SPF1-08C remains a popular choice for those seeking a reliable and portable cooling solution.
Faqs
How do I properly install the exhaust hose for the Air Conditioner?
Why is my Shinco not cooling properly?
How often should I clean the air filter of my Shinco Portable Air Conditioner SPF1-08C?
Can I use the Air Conditioner in a large room?
What is the power consumption of the Shinco AC?
How do I empty the dehumidifier tank of my Air Conditioner?
Can I use the remote control from another room?
How do I set up the 24-hour timer on my Shinco?
Is the Shinco Portable Air Conditioner SPF1-08C noisy?
What safety precautions should I take when using the Conditioner SPF1-08C?
Leave a Comment