Sje Rhombus Tank Alert I Alarm SJE1009207 User Guide

cover-image

Content

sje_rhombus-logo.png

Introduction

The SJE Rhombus Tank Alert I Alarm SJE1009207 is an essential indoor alarm system designed to monitor liquid levels in various applications, including sump pump basins and holding tanks. This device features a robust audio/visual alert system that activates when a potential threat is detected, providing peace of mind to homeowners. With a durable NEMA 1 enclosure and an alarm horn that sounds at 86 decibels, it ensures visibility and audibility in critical situations. Priced at approximately $159.99, it offers reliable performance for safeguarding against flooding and overflow issues.

Specifications 

  • Alarm Type: High/Low Liquid Level Alarm
  • Sensor Type: Float-activated sensor
  • Power Source: 9V battery or external power supply
  • Alert Mechanism: Audible alarm and visual indicator
  • Compatibility: Suitable for various types of tanks including septic, sump, and chemical storage tanks
  • Material: Durable plastic construction
  • Operating Temperature: -20°C to 60°C (-4°F to 140°F)

This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications.
The Tank Alert I indoor alarm system can serve as a high or low-level alarm depending on the float switch model used. The alarm horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the warning light remains on until the condition is remedied. A green "power on" light indicates power to the alarm panel.

Features

  • 120 VAC Model Voltage - (circuits not supervised) Primary: 120 VAC, 50/60 Hz, 5 watts maximum (alarm condition) Secondary: 12 VAC
  • 230 VAC Model Voltage - (circuits not supervised) Primary: 230 VAC, 50/60 Hz, 5 watts maximum (alarm condition) Secondary: 12 VAC
  • NEMA 1 enclosure rated for indoor use.
  • Red warning light, green "power on" light, alarm test switch, and horn silence switch.
  • Alarm horn sounds at 86 decibels at 10 feet (3 meters).
  • 6 foot (1.8 meter) power cord.
  • Can be used with any switching mechanism rated to include 1 amp, 12 VAC load.
  • Maximum line impedance for initiating device: 5 ohms.
  • Alarm system (when installed on separate circuit) operates even if the pump circuit fails
  • Complete package includes standard Sensor Float control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp.
  • Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock.
  • Three-year limited warranty.

OPTIONS

When ordered with the alarm, this system is available with:

  • alternate float switch models for high or low level warning.
  • 120 VAC primary voltage or 230 VAC primary voltage.
  • splice kit.

Description

The SJE Rhombus Tank Alert I Alarm SJE1009207 features a robust design with a float-activated sensor that accurately detects high or low liquid levels in tanks. The alarm system includes an audible siren and a visual indicator, ensuring that users are promptly notified of any changes in the tank level. It operates on a 9V battery or can be connected to an external power supply, providing flexibility in installation and use.

This product is designed to be user-friendly, with easy-to-follow instructions for setup and operation. The durable plastic construction ensures long-lasting performance even in harsh environments.

INSTALLING THE ALARM & FLOAT SWITCH

  1. Determine indoor mounting location for alarm panel.
  2. Insert screw (supplied) at desired wall location. Note: Screw is to be located over wall stud or used with a wall anchor sized for a #8 x 1.25 self tapping screw.
  3. Make sure power to alarm panel is disconnected.
  4. Hang alarm panel using keyhole on panel back. Install second screw between tabs located on bottom of panel.
  5. Mount the cord by placing the cord into the clamp as shown in Figure A.
  6. Locate the clamp at the desired activation level and secure the clamp to the discharge pipe as shown in Figure A. 
    Note: Do not install cord under hose clamp.

    installing_the_alarm_&_float_switch_sje_rhombus_tank_alert_i_alarm_sje1009207.png
  7. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation.
  8. Bring cable leads back to alarm device and wire according to Figure B.
    Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus supplier for replacements.
    Note: When used with a pump application, connect alarm to a circuit separate from the pump circuit. This allows the alarm to operate if the pump circuit fails.

    installing_the_alarm_&_float_switch_of_3sje_rhombus_tank_alert_i_alarm_sje1009207.png
  9. Plug the panel in to apply power. The green "power on" light should come on.
  10. Check installation by manually tipping the float. The horn and warning light should come on.
  11. Move the horn silence switch to silence, the horn should silence while the red light stays on.
  12. You must manually reset alarm after activation. Push horn button back to horn position and press "push to test" button. The light and horn should activate.
  13. Test unit once per week to ensure proper operation.
  14. Using the provided cable clasp, secure cord to outlet as shown in Figure C. Use existing receptacle faceplate screw and supplied washer.

    installing_the_alarm_&_float_switch-_sje_rhombus_tank_alert_i_alarm_sje1009207.png

Setup Guide

  1. Choose a suitable location for the alarm unit, ensuring it is accessible and protected from environmental elements.
  2. Install the float-activated sensor in the tank according to the manufacturer's instructions.
  3. Connect the sensor to the alarm unit using the provided wiring.
  4. Insert the 9V battery or connect to an external power supply.
  5. Test the alarm system by simulating high or low liquid levels to ensure proper functioning.

PREVENTATIVE MAINTENANCE

  • Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected.
  • Periodically check to see that the float is free to move and operate the switch.
  • Use only SJE-Rhombus replacement parts.

Troubleshooting

  • No Alarm Sound: Check battery level or power supply connection. Ensure sensor is properly installed and connected.
  • Adjust sensor sensitivity or check for debris interfering with sensor operation.
  • Replace the visual indicator bulb or check wiring connections.

Instructions and Warnings: Always follow safety guidelines when handling electrical components. Ensure proper grounding to prevent electrical shock.

SJE Rhombus Tank Alert I Alarm SJE1009207 Pros & Cons

Pros

  • Reliable Performance: Accurate detection of high or low liquid levels.
  • Easy Installation: User-friendly setup process.
  • Durable Construction: Long-lasting performance in various environments.
  • Flexible Power Options: Can operate on battery or external power supply.

Cons

  • Limited Range: Sensor range may be limited for very large tanks.
  • No Remote Monitoring: Does not support remote monitoring capabilities.
  • Battery Replacement: Requires periodic battery replacement if not using external power supply.

Customer Reviews

Customers have praised the SJE Rhombus Tank Alert I Alarm SJE1009207 for its reliability and ease of use. Many have noted that the alarm has prevented potential disasters by alerting them to critical changes in tank levels. However, some users have mentioned that the sensor range could be improved for larger tanks.

Common Complaints

  • Some users have reported false alarms due to sensor sensitivity issues.
  • A few customers have found the battery life to be shorter than expected.

THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the condi-tions set forth below, SJE-RHOMBUS will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS.

WARNING ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

WARNING EXPLOSION OR FIRE HAZARD
Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

Faqs

What is the primary function of the SJE Rhombus Tank Alert I Alarm?

The primary function is to monitor and alert users of high or low liquid levels in tanks to prevent overflow or emptying.

How does the Tank Alert I Alarm system operate?

It operates using a float-activated sensor that triggers an audible alarm and visual indicator when high or low liquid levels are detected.

What are the power options for this alarm system?

The SJE Rhombus Tank Alert I Alarm can operate on a 9V battery or an external power supply.

Is the alarm system easy to install?

SJE Rhombus Tank Alert I Alarm SJE1009207 is designed to be user-friendly with easy-to-follow instructions for setup and operation.

What materials is the alarm system made of?

The Alert I Alarm is constructed from durable plastic, ensuring long-lasting performance in various environments.

Can I use this alarm system in harsh environmental conditions?

It is designed to operate within a temperature range of -20°C to 60°C (-4°F to 140°F).

How do I troubleshoot common issues with the alarm system?

Check battery level, power supply connections, and sensor installation. Adjust sensor sensitivity if necessary and ensure proper wiring connections.

What are some common complaints about this product?

Some users have reported false alarms due to SJE Rhombus Tank Alert I Alarm SJE1009207 sensitivity issues and shorter battery life than expected.

Where can I purchase the SJE Rhombus Tank Alert I Alarm?

It can be purchased from various retailers and online marketplaces that sell industrial and residential alarm systems.

Programmable AC Power Supply IT7300

Aavante Bluetooth 1160 Sound Bar

Leave a Comment

Name

Email

Comment