Whynter Portable Air Conditioner ARC-08WB Instruction Manual

cover-image

Content

Introduction

The Whynter Portable Air Conditioner ARC-08WB is a compact and eco-friendly cooling solution designed for small to medium-sized spaces. With an 8,000 BTU capacity, it efficiently cools areas up to 250 square feet while operating quietly. This portable air conditioner features a sleek design, multiple fan speeds, and a dehumidifying function to enhance indoor comfort. Its user-friendly controls and easy installation make it a convenient choice for home or office use. The cost of the Whynter ARC-08WB is approximately $299.99, providing an effective and portable cooling option.

TECHNICAL DATA 

  • Cooling capacity
    8,000 BTU cooling capacity
  • Power supply
    115 V / 60Hz
  • Maximum power input
    910W
  • Maximum input
    8.2 Amps
  • Dehumidifying capacity
    45.6 Pts/day
  • Thermostat
    62° - 88°F (17°C - 30°C)
  • Refrigerant
    R410A
  • Air flow (max.)
    270m3/h /159CFM
  • Fan speeds
    3 (LOW and HIGH or AUTO)
  • Exhaust hose length
    59” / 5’
  • Unit Dimensions
    13.25" D x 13.75" W x 29" H
  • Unit Weight
    47.5 lbs

SAFETY PRECAUTIONS 

Before the appliance is used, it must be properly positioned and installed as detailed in this manual. 

DANGER

Before the appliance is used, it must be properly positioned and installed as detailed in this manual. 

  • Do not under any circumstances cut or remove the third (ground) prong from the power cord
  • Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or power strip
  • The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source
  • It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner
  • Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner
  • To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances
  • Do not repair, disassemble and/or modify the unit by yourself
  • Always turn off the portable air conditioner when cleaning the air filter, and transporting
  • Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch

WARNING

  • Do not under any circumstances cut or remove the third (ground) prong from the power cord
  • Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or power strip
  • The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source
  • It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner
  • Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner
  • To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances
  • Do not repair, disassemble and/or modify the unit by yourself
  • Always turn off the portable air conditioner when cleaning the air filter, and transporting
  • Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch
  • Do not allow children to climb, stand or hang on the appliance. The air conditioner could tip over and get damaged and/or seriously injure somebody
  • Keep fingers out of the air intakes and air outlets
  • The appliance is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions
  • When positioning or moving the appliance, ensure it is not turned upside down or greater than 45° or more off level
  • This appliance is designed for household, non-commercial use only. Any other use will void the warranty
  • Do not plug into the power outlet before set up is completed
  • Do not operate this unit without the air filter(s)
  • Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit
  • Do not add extra length to the exhaust hose by more than a total length of 9’. This will reduce the cooling efficiency of the portable air conditioner
  • At the end of each season, all water must be drained from the unit and filter(s) must be cleaned before storage

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED. 

OPERATING CONDITION 

operating_condition_whynter_portable_air_conditioner_arc-08wb.png
  • MODE
    ROOM TEMPERATURE
  • COOL
    Higher than 62°F / 17°C
  • DRY
    Higher than 54°F / 13°C

Your portable air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.

  1. Plug the power cord to a grounded wall outlet. Do not plug to a power strip or extension cord.
  2. Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and the unit comes on, please contact technical support.
  3. Press the RESET button to start the air conditioner.
  4. Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.

ACCESSORIES

identification_of_accessories_whynter_portable_air_conditioner_arc-08wb.png

IDENTIFICATION OF PARTS 

Front

front_miroir_usa_whynter_portable_air_conditioner_arc-08wb.png
  1. Control Panel
  2. Front Air Vent / Louvers
  3. Handles
  4. Remote Signal receptor
  5. Panel
    Rear
  6. Upper air filter
  7. Air outlet (hot air exhaust)
  8. Casters
  9. Upper air intake
  10. Upper drain port
  11. Lower air intake (Compressor)
  12. Lower air filter
  13. Lower drain port

    rear_whynter_portable_air_conditioner_arc-08wb.png

OPERATING YOUR AIR CONDITIONER

Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control.

CONTROL PANEL

control_panel_whynter_portable_air_conditioner_arc-08wb.png
  1. MODE Controls the 4 function modes: COOL, DRY (DEHUMIDIFY), FAN, and AUTO
  2. SLEEP Turns the sleep function on and off.
  3. UP & DOWN Adjusts set temperature (1°C/ 2°F increments) or timer hours (0 – 24 hours).NOTE: This unit is capable of displaying set temperature in Fahrenheit or in Celsius. To convert from one to the other, press and hold the Up and Down buttons for 3 seconds
  4. ON-OFF Turns the unit on and off.
  5. TIMER Turns the timer function on and off. To cancel the timer, press the On-Off button or set the timer to 0.0
  6. FAN Controls the 3 fan speeds: HI, LOW & AUTO. The fan speed indicator lights illuminates to show the set fan speed. When the AUTO speed is selected, none of the fan speed indicator illuminates.
  7. LED DISPLAY In Cool mode: shows set temperature in °C or °F and AUTO timer setting. In DRY and FAN only modes: shows room temperature.

Error Codes: E1, E2 & E4: Unplug unit and restart in 5 minutes. P1: Bottom water tank is full; drain water from the unit
NOTE: When more than one codes occur, the priority of the code display order is: E4--E2--E1--P1.

ARC-08WB Specifications 

  • Cooling Capacity: 8,000 BTU
  • Room Size: Up to 250 sq. ft.
  • Dehumidifying Capacity: 76 pints per day
  • Air Flow: 200 CFM
  • Noise Level: 54 dBA (low), 56 dBA (high)
  • Power Consumption: 920W / 7.8A
  • Dimensions: 27.7” H x 13.6” W x 15.4” D
  • Weight: 46 lbs
  • CERTIFICATIONS: UL, DOE, and Energy Star compliant

Description

The Whynter ARC-08WB features a sleek and compact design that makes it easy to move from room to room. It comes with a full set of accessories including a window kit, exhaust hose, and remote control. The unit operates on three fan speeds and has an automatic restart function in case of a power outage. The self-evaporating technology minimizes the need for frequent water drainage, making maintenance easier.

The ARC-08WB also includes an activated carbon filter to improve air quality and reduce odors. The unit is energy-efficient and environmentally friendly, meeting Energy Star standards. With its user-friendly interface and remote control, you can easily adjust settings from across the room.

INSTALLATION INSTRUCTIONS 

The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning.  

Cool or Auto Mode: Install Hose 

Dehumidify or Fan Mode: Remove Hose 

Exhaust Hose Installation 
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in Dehumidify or FAN only mode, no exhaust is required. 

  1. Pull out about 6” of one end of the exhaust hose.
  2. Install the flat mouth and sliding round exhaust connector on the exhaust hose by turning counter-clockwise. See Fig. 16 and 17
  3. Push in the exhaust hose into the air outlet port at the back of the unit. See Fig. 18

    installation_instructions_whynter_portable_air_conditioner_arc-08wb.png
  4. Only extend the exhaust hose to the necessary length. We do not recommend extending the exhaust hose more than 8' long. If you are interested in purchasing an additional 4’ exhaust hose please contact [email protected] for retail sales information.

NOTE

  • The duct can be compressed or extended moderately according to the installation requirement, but it is desirable to keep the exhaust hose length to a minimum.
  • Do not bend the exhaust hose
  • Make sure that there are no obstructions around the air outlet of the exhaust hose in order for the exhaust system to work properly

Air filter Installation 
Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an Activated Carbon Filter. The washable air filter removes large particles such as dust, pet hair and dander.   The Activated Carbon filter is designed to remove smoke and other odors. It is recommended you replace the Activated Carbon filter every 2-3 months or as needed. 

air_filter_installation_whynter_portable_air_conditioner_arc-08wb.png

WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE AIR FILTER 

Window kit Installation 
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dry or fan only mode, no exhaust is required.  Your window kit has been designed to fit most standard vertical and horizontal windows.  However, it may be necessary for you to modify the installation procedures for your window. Please refer to Fig. 6 & Fig. 7 for minimum and maximum window openings. 
NOTE:  

  • If your window opening is less than the mentioned minimum length of the window slider kit, cut the slide bar with hole to fit window opening. Never cut out the hole on the window slide bar. 
  • When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements maybe needed. 
  • The window slide bars can be fixed with the clear plastic bolt. See Fig. 7a 
window_kit_installation_whynter_portable_air_conditioner_arc-08wb.png

Window kit Installation in a double-hung window 

  1. Open window or sliding door for approximately 5”
  2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the window. Fig.10.
  3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 11.
  4. Close the window on the window slide bars. For long term installation, you may screw the window kit into your window frame. Fig. 12.
  5. Cut the foam seal to the length and seal the open gap between the top window sash and outer window sash. Shown in Fig.13.

    window_kit_installation_in_a_double-hung_window_of_whynter_portable_air_conditioner_arc-08wb.png

Window kit Installation in a sliding door/ window 

  1. Open window or sliding door for approximately 5”
  2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the door / window. See Fig.14.
  3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. See Fig. 15.
  4. Close the door/ window on the window slide bars. For long term installation, you may screw the window kit into your window frame. See Fig. 16.
  5. Cut the foam seal to the length and seal the open gap between the top window sash and outer window sash. See Fig.17.

    window_kit_installation_in_a_sliding_door-_window_installation_whynter_portable_air_conditioner_arc-08wb.png

OPERATION INSTRUCTIONS

BEFORE USING YOUR APPLIANCE

  • Remove the exterior and interior packing
  • Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation

SWITCHING ON/OFF THE AIR CONDITIONER

  • The appliance can be switched ON or OFF by pressing the On-Off button on the control panel or the On/Off button on the remote control

COOLING MODE

  • In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE button until the COOL indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air
  • The temperature setting range of this air conditioner is from 62°F / 17°C to 88°F / 30°C. To set the temperature, press the UP or DOWN buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner
  • To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings

DRY (DEHUMIDIFYING) ONLY MODE

  • In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the MODE button until the DRY indicator light comes on. Please note that when switching function mode, there will be an approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaust hose and let the warm air return to the room

AUTOMATIC MODE

  • When you set the air conditioner in AUTO mode, it will automatically select cooling or fan only operation depending on what temperature you have selected and the room temperature is close to the unit. The fan speed is automatically selected and cannot be changed
  • To operate the unit in Auto mode when the unit is on, press the Mode button until the indicator for “Auto” is lit

FAN ONLY MODE

  • In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button until the FAN indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the FAN button. Fan Only mode requires that the exhaust hose be removed

TIMER (DELAYED SWITCH ON / OFF) FUNCTION

  • This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled

SETTING SW ITCH OFF TIMER

  • With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set the desired time delay OFF hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel the delayed switch off function, turn off the air conditioner or adjust the time setting to 0.0.

SETTING DELAYED SWITCH ON TIMER

  • With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time delay ON hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch on function, turn on the air conditioner or adjust the time setting to 0.0.

SLEEP MODE

  • In this mode, the air conditioner gradually increases the set temperature in cooling mode, decreases the noise level and conserves energy. In Sleep & cooling mode, the set temperature is increased by 1°C/ 2°F in the first 30 minutes. The temperature will then increase by another
    1°C/ 2°F after an additional 30 minutes. This new temperature will remain the same for 7 hours. To activate this function mode, press the SLEEP button until the sleep indicated light comes on.

AUTO RESTART

  • In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.

CONTROLLING THE AIR FLOW DIRECTION

The louvers can be adjusted manually. To adjust the air flow direction, manually move the louvers to the desired position. The maximum setting angle is about 60°.

NOTE: Keep the louver fully opened during operation.

NOISE LEVEL

Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.

  • The compressor may make a pulsating or high-pitched sound
  • Water running from the evaporator to the water tank may make a splashing sound
  • Refrigerant flowing may make a gurgling sound
  • Fan sound may come from front and back air vents

WATER DRAINAGE

When the water level of the bottom tray reaches maximum level, the unit will beep 8 times and the digital display will show P1 symbol. Also, the cooling or dehumidifying function will stop and the fan only function will start.

Continuous drainage
In COOL or DRY modes, remove the upper drain plug from the back of the unit and install the drain water hose (5/8 universal female mender) with ¾” hose (can be purchased locally). If this part is unavailable from your local hardware store, just attach the drain hose to the drain firmly. The hose will fit snug which should prevent any leaking. Place the open end of the hose directly over the drain area in your basement floor. Please refer to Fig.21 & 22.

water_drainage_whynter_portable_air_conditioner_arc-08wb.png

Manual drainage
Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain (See Fig. 23). The P1 symbol will disappear and the cooling or dehumidifying function can be started. Be sure to reinstall the bottom drain plug before using the unit.

REMOTE CONTROL

remote_control_whynter_portable_air_conditioner_arc-08wb.png

The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.
NOTE:

  • Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences
  • Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner
  • Remove the batteries if the remote control is not used for long periods

INSTALLING BATTERIES 

  • Only use two dry LR03 AAA 1.5V Batteries (included) in the remote control
  • Always change both batteries at the same time

To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted. 

 

installing_batteries_whynter_portable_air_conditioner_arc-08wb.png
 

INDICATOR

FUNCTION

1 – Mode Indicator

Displays the currentselected mode

(Auto, Cool, Dry or Fan)

2 – Lock Indicator

Indicates unit is on Lock mode

3 – Temp./Timer Display

Displays temperature or timersetting

4 – Fan (High)

Displays the selected high fan speed

5 – Fan (Low)

Displays the selected low fan speed

6 – Timer Indicator

Indicates Timer mode activated

7 – Up Button

Increases set temperature/time

BUTTONS

FUNCTION

8 – Down Button

Decreases set temperature/time

9 – Mode Button

Controls the 4 function modes:

Auto, Cool, Dry & Fan

10 – On/Off Button

Turns the unit On and Off

11 – Fan SpeedButton

Controls the 3 fan speeds:High & Low or Auto

12 – Sleep Button

Enables Sleep mode

13 – Timer On Button

Enables the On timer& set timerhours

14 – Reset Button

Cancels all settings

15 – Timer Off Button

Enables the Off timer& set timerhours

16 – Lock Button

Locks all settings

17 – LED DisplayButton

Turns on and off the displaylight

Setup Guide

To set up the Whynter ARC-08WB, 

  • Start by unpacking all the components and ensuring everything is included. 
  • Connect the exhaust hose to the back of the unit and attach the other end to the window kit. Install the window kit in your window according to the instructions provided.
  • Plug in the air conditioner and turn it on using the remote control or the control panel on the unit. 
  • Choose your desired settings such as fan speed, cooling mode, or dehumidify mode. 
  • Ensure proper ventilation by directing the exhaust hose outside.

CARE AND MAINTENANCE 

IMPORTANT: 

  • Switch off the air conditioner and disconnect the plug from the power outlet
  • Drain water by removing the drain plug
  • Always transport the air conditioner in an upright position only

CLEANING THE AIR FILTERS 

  • To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the air filters at least once every two weeks
  • This unit has two pre-filters; the upper and the lower filters
  • Switch off the air conditioner and pull out the upper and lower air filter from the unit by following the arrow directions shown.
  • Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the filters. Then rinse them thoroughly under warm or cold running water (no hotter than 100F.)
  • Dry thoroughly before re-inserting the filters

    cleaning_the_air_filters_whynter_portable_air_conditioner_arc-08wb.png

CLEANING THE AIR CONDITIONER 

  • Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner
  • Use a soft damp cloth to wipe the body of the unit.
  • Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the body of the air conditioner

END OF SEASON STORAGE 

  • Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner
  • Clean the air filters
  • Drain the condensed water completely
  • On a warm day, turn on the Fan only mode for half a day so that the inside can dry out completely
  • Wrapped the power cord and bundle it with the tape
  • Remove the batteries from the remote controller
  • Disconnect the exhaust hose
  • It is recommended that the air conditioner be put back into its original carton for storage

TROUBLESHOOTING

Problem

Possible Causes

Solutions

The portable air conditioner does not turn on

  • Power failure / outage

  • The automatic switch,line fuse, or breaker has been tripped

 

 

  • The power supplyvoltage is too low
  • The power cord is damaged

 

 

  • The L.C.D.I. powerplug for the unit is tripped
  • The internal waterreservoir is full and ‘P1” appears on display
  • Restore the power supply
  • Flip the switch / change the fuse / turn the breaker backon. Also note that you may have too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit
  • Move the unitonto another circuitwith the correct voltage
  • Call for service. Only authorized personnel should replacedamaged power cord or power plug
  • Press the Resetbutton on the L.C.D.I. power plug
  • Drain water from the air conditioner
  • Possible loose internal connection. Please contact Whynter for service

The unit turns on but the compressor does not turn on (the fan runs but the unit is not cooling)

  • The room temperature is outside of the operational tolerances of the unit

  • The Cooling mode is not on

 

  • The compressor has not turned on yet becauseof its time delay
  • The set temperature is too high

 

 

  • The internal waterreservoir is full and ‘P1” appears on display
  • This unit is designed to work in ambient temperatures of 64°F to 90°F

 

  • Press the MODEbutton until the COOL lightis shown on the display
  • Give the compressor 3 minutes to turn on after the Cooling mode has been selected

 

  • Set the air conditioner to a lower temperature. It is recommended to set thetemperature to at least 5°F of the ambient temperature

  • Either manually drain the waterby removing

the drain plugor allow the unit to exhaust the water itself by running the fan only mode.

Then cooling will resume

  • Possible loose internal connection. Please contact Whynter for service

The air coming out of the unit is not very cold, or the airflow volume is weak

  • The filters aredirty or obstructed
  • The air intakeor exhaust is obstructed

 

  • The unit is set in DRY or FAN mode
  • The unit is set to low fan speed
  • Clean the air filters

 

  • Make sure thereis at least 20" of clearance from the air intake. Make the length of the exhaust hose is as short as possible
  • Set the unitto the cooling mode

 

  • Set the unit to a higherfan speed

The unit has worked for a long time, but the roomis not coldenough

  • Windows or doors are open

 

  • There are too many people in the room

 

  • There is directsunshine into the room

 

  • The room is a kitchenor with many heat-producing appliances

 

  • There is a serverin the room

 

  • The room is too large
  • Close allwindows and doors

 

  • You may needadditional cooling or another air conditioner

 

  • Close curtains or blinds and try to minimize the amount of direct sunlight into the room

 

  • You may needadditional cooling or another air conditioner

 

 

  • You may needadditional cooling or another air conditioner
  • You may needadditional cooling or

The unit is very noisy

  • The unit is notlevel

 

 

  • The surface underneath the unit is uneven

 

  • Low power voltage
  • Make sure the unit is on hard,level and stable surface

 

  • Move the unit to a location with a leveland hard floor

 

  • Make sure the wall outletand support the required power consumption of the air conditioner and do not use an extension cord

The unit leakswater

  • The unit is tilted or not leveled

 

  • The water tank is full
  • Make usethe unit is leveled

 

  • Drain water fromthe drain plug at the back of the air conditioner

Fan speedcannot be changed

  • Fan speed differences are not very noticeable
  • The fan speed difference is not very noticeable whenthe compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings

Whynter ARC-08WB Pros & Cons

Pros

  • Compact and portable design
  • Self-evaporating technology reduces maintenance
  • The dehumidifying function helps maintain comfortable humidity levels
  • Energy-efficient and Environmentally friendly
  • Includes remote control for easy operation

Cons

  • Noisy operation on high fan speed
  • Some users find it heavy to move around
  • Limited cooling capacity for larger rooms
  • May require periodic filter cleaning

Customer Reviews

Customers generally praise the Whynter ARC-08WB for its effectiveness in cooling small rooms quickly. Many appreciate its ease of setup and the convenience of the remote control. However, some users have noted that it can be noisy on the highest fan setting and may not be as effective in larger spaces.

Common complaints 

Include issues with customer service and occasional leaks if not properly installed.

Warranty

ONE-YEAR LIMITED WARRANTY & THREE-YEAR WARRANTY ON COMPRESSOR

This W HYNTER portable air conditioner is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your W HYNTER portable air conditioner prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months to one year, the customer will be responsible for freight cost to Whynter’s service department), along with an explanation of the claim to Whynter LLC. Please package the portable air conditioner carefully in its original packaging material to avoid damage in transit.

Faqs

How do I properly install the window kit for the Whynter ARC-08WB?

To install the window kit, first measure your window to ensure the kit fits. Cut the plastic panel to size if necessary, then attach it to your window frame using the provided Velcro strips. Connect one end of the exhaust hose to the back of the air conditioner and direct the other end through the window kit.

Why is my Whynter ARC-08WB not cooling my room effectively?

If your Whynter ARC-08WB is not cooling effectively, check that the exhaust hose is securely connected and directed outside. Ensure there are no blockages around the air intake grille and that you are using it in a room within its recommended size range (up to 250 sq. ft.).

How often should I clean the filter on my Whynter ARC-08WB?

It is recommended to clean or replace the filter every two weeks depending on usage and environment. A dirty filter can reduce efficiency and air quality.

What is self-evaporating technology in the Whynter ARC-08WB?

Self-evaporating technology allows the air conditioner to evaporate most of its condensate automatically, reducing the need for frequent water drainage. However, under high humidity conditions, some water collection may still occur.

Can I use my Whynter ARC-08WB in a room larger than 250 sq. ft.?

While it is possible to use it in a larger room, it may not cool as effectively. The recommended room size is up to 250 sq. ft., so using it in larger spaces may result in reduced performance.

Is the Whynter ARC-08WB energy-efficient?

Yes, the Whynter ARC-08WB is energy-efficient and meets Energy Star standards. It consumes 920W of power which is relatively low compared to other models on the market.

How noisy is the Whynter ARC-08WB during operation?

The noise level of the Whynter ARC-08WB ranges from 54 dBA on low fan speed to 56 dBA on high fan speed. While it is generally quiet, some users find it noisy on high settings.

Does the Whynter ARC-08WB come with a remote control?

Yes, the Whynter ARC-08WB comes with a remote control that allows you to adjust settings such as fan speed, cooling mode, and timer from across the room.

What certifications does the Whynter ARC-08WB have?

The Whynter ARC-08WB is certified by UL (Underwriters Laboratories), DOE (Department of Energy), and meets Energy Star standards for efficiency and safety.

How do I reset my Whynter ARC-08WB after a power outage?

The Whynter ARC-08WB has an automatic restart function that turns it back on with previous settings after a power outage. If this does not happen automatically, simply press any button on the remote or control panel to restart it manually.

WiFi Smart Converter SH330W

AlphaTrak 3 Blood Glucose Monitoring

Leave a Comment

Name

Email

Comment