The Whynter Portable Air Conditioner ARC-08WB is a compact and eco-friendly cooling solution designed for small to medium-sized spaces. With an 8,000 BTU capacity, it efficiently cools areas up to 250 square feet while operating quietly. This portable air conditioner features a sleek design, multiple fan speeds, and a dehumidifying function to enhance indoor comfort. Its user-friendly controls and easy installation make it a convenient choice for home or office use. The cost of the Whynter ARC-08WB is approximately $299.99, providing an effective and portable cooling option.
TECHNICAL DATA
- Cooling capacity
8,000 BTU cooling capacity - Power supply
115 V / 60Hz - Maximum power input
910W - Maximum input
8.2 Amps - Dehumidifying capacity
45.6 Pts/day - Thermostat
62° - 88°F (17°C - 30°C) - Refrigerant
R410A - Air flow (max.)
270m3/h /159CFM - Fan speeds
3 (LOW and HIGH or AUTO) - Exhaust hose length
59” / 5’ - Unit Dimensions
13.25" D x 13.75" W x 29" H - Unit Weight
47.5 lbs
SAFETY PRECAUTIONS
Before the appliance is used, it must be properly positioned and installed as detailed in this manual.
DANGER
Before the appliance is used, it must be properly positioned and installed as detailed in this manual.
- Do not under any circumstances cut or remove the third (ground) prong from the power cord
- Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or power strip
- The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source
- It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner
- Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner
- To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances
- Do not repair, disassemble and/or modify the unit by yourself
- Always turn off the portable air conditioner when cleaning the air filter, and transporting
- Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch
WARNING
- Do not under any circumstances cut or remove the third (ground) prong from the power cord
- Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or power strip
- The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source
- It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner
- Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner
- To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances
- Do not repair, disassemble and/or modify the unit by yourself
- Always turn off the portable air conditioner when cleaning the air filter, and transporting
- Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch
- Do not allow children to climb, stand or hang on the appliance. The air conditioner could tip over and get damaged and/or seriously injure somebody
- Keep fingers out of the air intakes and air outlets
- The appliance is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions
- When positioning or moving the appliance, ensure it is not turned upside down or greater than 45° or more off level
- This appliance is designed for household, non-commercial use only. Any other use will void the warranty
- Do not plug into the power outlet before set up is completed
- Do not operate this unit without the air filter(s)
- Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit
- Do not add extra length to the exhaust hose by more than a total length of 9’. This will reduce the cooling efficiency of the portable air conditioner
- At the end of each season, all water must be drained from the unit and filter(s) must be cleaned before storage
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
OPERATING CONDITION
- MODE
ROOM TEMPERATURE - COOL
Higher than 62°F / 17°C - DRY
Higher than 54°F / 13°C
Your portable air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.
- Plug the power cord to a grounded wall outlet. Do not plug to a power strip or extension cord.
- Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and the unit comes on, please contact technical support.
- Press the RESET button to start the air conditioner.
- Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.
ACCESSORIES
IDENTIFICATION OF PARTS
Front
- Control Panel
- Front Air Vent / Louvers
- Handles
- Remote Signal receptor
- Panel
Rear - Upper air filter
- Air outlet (hot air exhaust)
- Casters
- Upper air intake
- Upper drain port
- Lower air intake (Compressor)
- Lower air filter
Lower drain port
OPERATING YOUR AIR CONDITIONER
Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control.
CONTROL PANEL
- MODE Controls the 4 function modes: COOL, DRY (DEHUMIDIFY), FAN, and AUTO
- SLEEP Turns the sleep function on and off.
- UP & DOWN Adjusts set temperature (1°C/ 2°F increments) or timer hours (0 – 24 hours).NOTE: This unit is capable of displaying set temperature in Fahrenheit or in Celsius. To convert from one to the other, press and hold the Up and Down buttons for 3 seconds
- ON-OFF Turns the unit on and off.
- TIMER Turns the timer function on and off. To cancel the timer, press the On-Off button or set the timer to 0.0
- FAN Controls the 3 fan speeds: HI, LOW & AUTO. The fan speed indicator lights illuminates to show the set fan speed. When the AUTO speed is selected, none of the fan speed indicator illuminates.
- LED DISPLAY In Cool mode: shows set temperature in °C or °F and AUTO timer setting. In DRY and FAN only modes: shows room temperature.
Error Codes: E1, E2 & E4: Unplug unit and restart in 5 minutes. P1: Bottom water tank is full; drain water from the unit
NOTE: When more than one codes occur, the priority of the code display order is: E4--E2--E1--P1.
ARC-08WB Specifications
- Cooling Capacity: 8,000 BTU
- Room Size: Up to 250 sq. ft.
- Dehumidifying Capacity: 76 pints per day
- Air Flow: 200 CFM
- Noise Level: 54 dBA (low), 56 dBA (high)
- Power Consumption: 920W / 7.8A
- Dimensions: 27.7” H x 13.6” W x 15.4” D
- Weight: 46 lbs
- CERTIFICATIONS: UL, DOE, and Energy Star compliant
Description
The Whynter ARC-08WB features a sleek and compact design that makes it easy to move from room to room. It comes with a full set of accessories including a window kit, exhaust hose, and remote control. The unit operates on three fan speeds and has an automatic restart function in case of a power outage. The self-evaporating technology minimizes the need for frequent water drainage, making maintenance easier.
The ARC-08WB also includes an activated carbon filter to improve air quality and reduce odors. The unit is energy-efficient and environmentally friendly, meeting Energy Star standards. With its user-friendly interface and remote control, you can easily adjust settings from across the room.
INSTALLATION INSTRUCTIONS
The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning.
Cool or Auto Mode: Install Hose
Dehumidify or Fan Mode: Remove Hose
Exhaust Hose Installation
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in Dehumidify or FAN only mode, no exhaust is required.
- Pull out about 6” of one end of the exhaust hose.
- Install the flat mouth and sliding round exhaust connector on the exhaust hose by turning counter-clockwise. See Fig. 16 and 17
Push in the exhaust hose into the air outlet port at the back of the unit. See Fig. 18
- Only extend the exhaust hose to the necessary length. We do not recommend extending the exhaust hose more than 8' long. If you are interested in purchasing an additional 4’ exhaust hose please contact [email protected] for retail sales information.
NOTE
- The duct can be compressed or extended moderately according to the installation requirement, but it is desirable to keep the exhaust hose length to a minimum.
- Do not bend the exhaust hose
- Make sure that there are no obstructions around the air outlet of the exhaust hose in order for the exhaust system to work properly
Air filter Installation
Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an Activated Carbon Filter. The washable air filter removes large particles such as dust, pet hair and dander. The Activated Carbon filter is designed to remove smoke and other odors. It is recommended you replace the Activated Carbon filter every 2-3 months or as needed.
WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE AIR FILTER
Window kit Installation
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dry or fan only mode, no exhaust is required. Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary for you to modify the installation procedures for your window. Please refer to Fig. 6 & Fig. 7 for minimum and maximum window openings.
NOTE:
- If your window opening is less than the mentioned minimum length of the window slider kit, cut the slide bar with hole to fit window opening. Never cut out the hole on the window slide bar.
- When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements maybe needed.
- The window slide bars can be fixed with the clear plastic bolt. See Fig. 7a
Window kit Installation in a double-hung window
- Open window or sliding door for approximately 5”
- Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the window. Fig.10.
- Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 11.
- Close the window on the window slide bars. For long term installation, you may screw the window kit into your window frame. Fig. 12.
Cut the foam seal to the length and seal the open gap between the top window sash and outer window sash. Shown in Fig.13.
Window kit Installation in a sliding door/ window
- Open window or sliding door for approximately 5”
- Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the door / window. See Fig.14.
- Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. See Fig. 15.
- Close the door/ window on the window slide bars. For long term installation, you may screw the window kit into your window frame. See Fig. 16.
Cut the foam seal to the length and seal the open gap between the top window sash and outer window sash. See Fig.17.
OPERATION INSTRUCTIONS
BEFORE USING YOUR APPLIANCE
- Remove the exterior and interior packing
- Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
- The appliance can be switched ON or OFF by pressing the On-Off button on the control panel or the On/Off button on the remote control
COOLING MODE
- In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE button until the COOL indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air
- The temperature setting range of this air conditioner is from 62°F / 17°C to 88°F / 30°C. To set the temperature, press the UP or DOWN buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner
- To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings
DRY (DEHUMIDIFYING) ONLY MODE
- In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the MODE button until the DRY indicator light comes on. Please note that when switching function mode, there will be an approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaust hose and let the warm air return to the room
AUTOMATIC MODE
- When you set the air conditioner in AUTO mode, it will automatically select cooling or fan only operation depending on what temperature you have selected and the room temperature is close to the unit. The fan speed is automatically selected and cannot be changed
- To operate the unit in Auto mode when the unit is on, press the Mode button until the indicator for “Auto” is lit
FAN ONLY MODE
- In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button until the FAN indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the FAN button. Fan Only mode requires that the exhaust hose be removed
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
- This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled
SETTING SW ITCH OFF TIMER
- With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set the desired time delay OFF hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel the delayed switch off function, turn off the air conditioner or adjust the time setting to 0.0.
SETTING DELAYED SWITCH ON TIMER
- With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time delay ON hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch on function, turn on the air conditioner or adjust the time setting to 0.0.
SLEEP MODE
- In this mode, the air conditioner gradually increases the set temperature in cooling mode, decreases the noise level and conserves energy. In Sleep & cooling mode, the set temperature is increased by 1°C/ 2°F in the first 30 minutes. The temperature will then increase by another
1°C/ 2°F after an additional 30 minutes. This new temperature will remain the same for 7 hours. To activate this function mode, press the SLEEP button until the sleep indicated light comes on.
AUTO RESTART
- In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.
CONTROLLING THE AIR FLOW DIRECTION
The louvers can be adjusted manually. To adjust the air flow direction, manually move the louvers to the desired position. The maximum setting angle is about 60°.
NOTE: Keep the louver fully opened during operation.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.
- The compressor may make a pulsating or high-pitched sound
- Water running from the evaporator to the water tank may make a splashing sound
- Refrigerant flowing may make a gurgling sound
- Fan sound may come from front and back air vents
WATER DRAINAGE
When the water level of the bottom tray reaches maximum level, the unit will beep 8 times and the digital display will show P1 symbol. Also, the cooling or dehumidifying function will stop and the fan only function will start.
Continuous drainage
In COOL or DRY modes, remove the upper drain plug from the back of the unit and install the drain water hose (5/8 universal female mender) with ¾” hose (can be purchased locally). If this part is unavailable from your local hardware store, just attach the drain hose to the drain firmly. The hose will fit snug which should prevent any leaking. Place the open end of the hose directly over the drain area in your basement floor. Please refer to Fig.21 & 22.
Manual drainage
Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain (See Fig. 23). The P1 symbol will disappear and the cooling or dehumidifying function can be started. Be sure to reinstall the bottom drain plug before using the unit.
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.
NOTE:
- Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences
- Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner
- Remove the batteries if the remote control is not used for long periods
INSTALLING BATTERIES
- Only use two dry LR03 AAA 1.5V Batteries (included) in the remote control
- Always change both batteries at the same time
To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted.
| INDICATOR | FUNCTION | |
1 – Mode Indicator | Displays the currentselected mode (Auto, Cool, Dry or Fan) | ||
2 – Lock Indicator | Indicates unit is on Lock mode | ||
3 – Temp./Timer Display | Displays temperature or timersetting | ||
4 – Fan (High) | Displays the selected high fan speed | ||
5 – Fan (Low) | Displays the selected low fan speed | ||
6 – Timer Indicator | Indicates Timer mode activated | ||
7 – Up Button | Increases set temperature/time | ||
BUTTONS | FUNCTION | ||
8 – Down Button | Decreases set temperature/time | ||
9 – Mode Button | Controls the 4 function modes: Auto, Cool, Dry & Fan | ||
10 – On/Off Button | Turns the unit On and Off | ||
11 – Fan SpeedButton | Controls the 3 fan speeds:High & Low or Auto | ||
12 – Sleep Button | Enables Sleep mode | ||
13 – Timer On Button | Enables the On timer& set timerhours | ||
14 – Reset Button | Cancels all settings | ||
15 – Timer Off Button | Enables the Off timer& set timerhours | ||
16 – Lock Button | Locks all settings | ||
17 – LED DisplayButton | Turns on and off the displaylight |
Setup Guide
To set up the Whynter ARC-08WB,
- Start by unpacking all the components and ensuring everything is included.
- Connect the exhaust hose to the back of the unit and attach the other end to the window kit. Install the window kit in your window according to the instructions provided.
- Plug in the air conditioner and turn it on using the remote control or the control panel on the unit.
- Choose your desired settings such as fan speed, cooling mode, or dehumidify mode.
- Ensure proper ventilation by directing the exhaust hose outside.
CARE AND MAINTENANCE
IMPORTANT:
- Switch off the air conditioner and disconnect the plug from the power outlet
- Drain water by removing the drain plug
- Always transport the air conditioner in an upright position only
CLEANING THE AIR FILTERS
- To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the air filters at least once every two weeks
- This unit has two pre-filters; the upper and the lower filters
- Switch off the air conditioner and pull out the upper and lower air filter from the unit by following the arrow directions shown.
- Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the filters. Then rinse them thoroughly under warm or cold running water (no hotter than 100F.)
Dry thoroughly before re-inserting the filters
CLEANING THE AIR CONDITIONER
- Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner
- Use a soft damp cloth to wipe the body of the unit.
- Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the body of the air conditioner
END OF SEASON STORAGE
- Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner
- Clean the air filters
- Drain the condensed water completely
- On a warm day, turn on the Fan only mode for half a day so that the inside can dry out completely
- Wrapped the power cord and bundle it with the tape
- Remove the batteries from the remote controller
- Disconnect the exhaust hose
- It is recommended that the air conditioner be put back into its original carton for storage
TROUBLESHOOTING
Problem | Possible Causes | Solutions |
The portable air conditioner does not turn on |
|
|
The unit turns on but the compressor does not turn on (the fan runs but the unit is not cooling) |
|
the drain plugor allow the unit to exhaust the water itself by running the fan only mode. Then cooling will resume
|
The air coming out of the unit is not very cold, or the airflow volume is weak |
|
|
The unit has worked for a long time, but the roomis not coldenough |
|
|
The unit is very noisy |
|
|
The unit leakswater |
|
|
Fan speedcannot be changed |
|
|
Whynter ARC-08WB Pros & Cons
Pros
- Compact and portable design
- Self-evaporating technology reduces maintenance
- The dehumidifying function helps maintain comfortable humidity levels
- Energy-efficient and Environmentally friendly
- Includes remote control for easy operation
Cons
- Noisy operation on high fan speed
- Some users find it heavy to move around
- Limited cooling capacity for larger rooms
- May require periodic filter cleaning
Customer Reviews
Customers generally praise the Whynter ARC-08WB for its effectiveness in cooling small rooms quickly. Many appreciate its ease of setup and the convenience of the remote control. However, some users have noted that it can be noisy on the highest fan setting and may not be as effective in larger spaces.
Common complaints
Include issues with customer service and occasional leaks if not properly installed.
Warranty
ONE-YEAR LIMITED WARRANTY & THREE-YEAR WARRANTY ON COMPRESSOR
This W HYNTER portable air conditioner is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your W HYNTER portable air conditioner prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months to one year, the customer will be responsible for freight cost to Whynter’s service department), along with an explanation of the claim to Whynter LLC. Please package the portable air conditioner carefully in its original packaging material to avoid damage in transit.
Faqs
How do I properly install the window kit for the Whynter ARC-08WB?
Why is my Whynter ARC-08WB not cooling my room effectively?
How often should I clean the filter on my Whynter ARC-08WB?
What is self-evaporating technology in the Whynter ARC-08WB?
Can I use my Whynter ARC-08WB in a room larger than 250 sq. ft.?
Is the Whynter ARC-08WB energy-efficient?
How noisy is the Whynter ARC-08WB during operation?
Does the Whynter ARC-08WB come with a remote control?
What certifications does the Whynter ARC-08WB have?
How do I reset my Whynter ARC-08WB after a power outage?
Leave a Comment