Homech Ultrasonic Cool Mist Humidifier HM-AH001 User Manual
Content
Homech Ultrasonic Cool Mist Humidifier HM-AH001 Introduction
Ensuring ideal humidity levels for a comfortable living space is the goal of the Homech Ultrasonic Cool Mist Humidifier HM-AH001. This humidifier's enormous 4L water tank allows it to run continuously for up to 60 hours, providing medium-to-large-sized rooms with a long-lasting mist. For preserving the purity of the air in your house, its silent ultrasonic technology, customizable mist settings, and automated shut-off feature make it a dependable and easy-to-use option for a price is $29.99.
PACKAGE CONTENTS
- 1 x Homech Humidifier (Model: HM-AH001)
- 1 x Cleaning Brush
- 1 x Dustproof Sponge
- 1 x Thank You Card
- 1 x User Manual
SPECIFICATIONS
Model | HM-AH001 |
Operating Voltage | AC100-120V 50 / 60Hz |
Rated Power | Min: 15W Max: 25W |
Water Tank Capacity | 4.0L / 1.06Gal |
Mist Output | Min: 60ml/h Max: 300ml/h |
Working Time on a Full Tank | 12-50h |
Recommended Room Size | 20-40m² / 215-430ft² |
Noise | <27dB |
Dimensions | 258 x 164 x 338mm / 10.2 x 6.5 x 13.3in |
Net Weight | 1350g / 47.6oz |
PRODUCT DIAGRAM
- Nozzle
- Handle
- Water Tank
- Water Level Window
- Base
- Power Cord
- Control Knob
- LED Indicator
- Muffler
- Tank Cap
- Water Inlet
- Air Outlet
- Water Reservoir
- Atomizer
- Water Floater
- Dustproof Sponge
- Air Inlet
Description
The best option for enhancing the air quality in your house is the Homech Ultrasonic Cool Mist Humidifier HM-AH001. It is ideal for use in workplaces and bedrooms because of its ultrasonic technology, which enables silent and effective functioning. With its 360-degree rotatable nozzle, you can guide the mist precisely where you need it, and its automatic shut-off feature saves energy and assures safety. Convenient and low-maintenance, this humidifier boasts a spacious 4-liter water tank that allows for continuous usage for up to 24 hours. The adjustable LED night light and easy-to-clean design enhance this humidifier's usability and convenience. In order to maintain the ideal humidity level in your environment, the HM-AH001 also has an intelligent auto mode and a humidity level detection feature.
OPERATIONS AND FUNCTIONS
Add water
- Turn the water tank upside down. Remove the tank cap and fill the tank with clean and cool water only.
- Attach the tank cap and place the tank back onto the base. Please make sure it fits together securely so that water can go from the tank to the reservoir.
- If tap water is too hard, it is recommended to use filtered or distilled water to avoid white dust. DO NOT use hot water.
- DO NOT add any essential oils or medicinal tablets into the water tank.
- DO NOT add water into the base or through nozzle.
- DO NOT move the humidifier while the water tank is full of water to avoid leakage or base overfilling.
Control Panel
Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidifier is ready for use.
- Rotate the control knob clockwise to the ON position. The white LED indicator will light up indicating the humidifier has been turned on to a minimum mist level.
- Keep rotating the control knob clockwise to increase the mist level.
- Rotate the control knob counterclockwise to the OFF position to turn off the humidifier. The LED indicator will turn off. The fan will work for another 3 minutes to dry the mist tube.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
Low Water Protection: Auto Shut-off the Humidifier
When there is not enough water inside the water reservoir, the humidifier will stop misting and the LED indicator will become red. It is designed for safety to prevent the humidifier from possibly overheating and damaging the atomizer.
Setup Guide
Setting up the Homech Ultrasonic Cool Mist Humidifier HM-AH001 is a breeze:
- Remove the humidifier from the packaging and rinse the water tank with clean water.
- Fill the water tank with clean, cool water up to the indicated maximum level.
- Place the water tank back onto the base of the humidifier, ensuring that it is securely in place.
- Plug in the humidifier and turn it on using the power button.
- Adjust the mist output and LED night light as desired.
- Set the humidifier to automatic mode for intelligent humidity level control, or manual mode for customized settings.
CLEANING AND MAINTENANCE
Caution
- DO NOT submerge the base in water.
- Make sure water does not enter the base through the air outlet, air inlet, or the control knob.
- DO NOT wash any part of this humidifier in dish washer which will damage the humidifier and void the warranty.
Daily Maintenance
Turn off the humidifier, unplug it from the power source. Drain water from the tank, reservoir and base.
Weekly Maintenance
- To properly clean your humidifier, we recommend you to remove scale and disinfect the humidifier separately.
- DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of bleach per gallon of water to avoid damaging your humidifier.
- Please make sure the sealing ring on the tank cap is installed properly after cleaning to avoid water leakage.
Scale Removal Instructions
- Turn off and unplug the humidifier.
- Remove the water tank from the base. Remove the tank cap. Make sure that the white sealing ring does not come off. Drain water from the water tank and base. Remove any accessories and set aside.
- Fill the water tank half full. Add in 1 teaspoon of undiluted distilled white vinegar. Attach the tank cap and shake for 15 seconds.
- Place the tank onto the base. The vinegar solution will enter the water reservoir to loosen mineral buildup (scale) on the atomizer, water floater and the bottom of the water tank. Set still for 15-20 minutes.
- Uncap the tank cap and drain the solution. Wipe the atomizer and floater with a soft cloth to remove loosened mineral deposits.
- Rinse both the water reservoir and water tank until the smell of vinegar (for scale removal) or bleach solution (for disinfecting, see below) is gone.
Disinfecting Instructions
- Follow steps 1-2 of the previous section on scale removal.
- Fill the water tank half full. Add in ½ tsp of bleach. Place the tank cap back on. Swish the solution around in tank. Place the tank on the base. The bleach solution will enter and disinfect the water reservoir as well as the other components. Set still for 15-20 minutes.
- Follow steps 4-6 of the previous section on scale removal to complete disinfecting the humidifier.
Clean the Dustproof Sponge
Clean the dustproof sponge (at the bottom of base) with water or detergent once a month. Put it back in place after cleaning.
End-Of-Season Care and Storage
- Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season. Remove any accessories used with the humidifier and allow the humidifier and accessories to dry completely before storing.
- DO NOT store with water inside the base, water reservoir, or tank.
- Pack the unit safely and store in a cool, dry location.
BEFORE USING THE HUMIDIFIER
- Please extend the cord and check any signs of damage. Do not use the humidifier if the cord has been damaged.
- DO NOT place this humidifier in wet environments.
Please always keep the humidifier out of reach of patients & children & pet.
- Please always place the unit on a smooth, flat, lint-free, non-metallic, waterproof and level surface and keep it away from direct sunlight.
- Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall, other appliances or wooden furniture.
- DO NOT place the unit on carpet, towel or wood surface, which will block the vent and may damage the unit.
- DO NOT place the humidifier near naked flames and heat sources, such as stove tops, ovens, radiators or computers.
WHEN USING THE HUMIDIFIER
- DO NOT plug the unit with wet hands.
- DO NOT direct the mist nozzle against the wall.
- DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury.
- DO NOT clean the unit while it is connected to a power source or while it is on.
- DO NOT move or tilt the humidifier while it is in operation.
- The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
AFTER USING THE HUMIDIFIER
- Always disconnect from a power source by pulling the plug when not in use.
- Humidifier requires regular cleaning. Please refer to, and follow the Cleaning and Maintenance instructions.
- DO NOT clean the humidifier right after turning it off if the humidifier has been diffusing warm mist. Allow the humidifier to completely cool down before cleaning.
- DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier. Doing so will void your warranty.
Troubleshooting
- If the information listed in the troubleshooting guide can’t solve your problem, please email us for help.
- Failure to keep this unit clean from mineral deposits may affect operation of this unit.
- Customer failure to follow these instructions may void the warranty.
Problem | Possible Cause | Solution |
---|---|---|
LED indicator is off | Unit not plugged in | Ensure unit is properly plugged in |
No power from power outlet | Try another power outlet | |
Did not turn on the unit | Check the Control Knob is turned to the ON position | |
LED indicator stays red | No water in the water reservoir | Ensure the 1️⃣ Spring is secured properly to the tank bottom allowing water to pass through to the base |
3️⃣ Water floater stuck | Adjust the 3️⃣ water floater to a horizontal position and make sure it can rise up with water | |
The LED Indicator is white but no mist or little mist is produced | Not enough water inside the tank | Refill and reinstall the water tank |
Mist level is set too low | Adjust to maximum mist | |
Mineral buildup on the atomizer | Feel if any air comes out from the nozzle. If yes, then clean water scale on the atomizer as instructed | |
The base might be overfilled | Remove the tank, empty the base and place the filled tank on the empty base | |
Tank leakage | Tank may be damaged | Check for possible cracks in the tank, replace if necessary |
Tank cap is not tightened securely | Tighten the tank cap | |
1️⃣ Spring stuck | Ensure the 1️⃣ spring is properly secured to the tank bottom allowing water to pass through to the base | |
2️⃣ Sealing ring was not installed on tank cap | Install the 2️⃣ sealing ring on the tank cap, please contact us if it is missing | |
Mist height is low, damping surrounding desk or floor. Condensation forms around humidifier or on windows and walls | Mist level is set too high for the room size | 1. Check if the room is too humid and adjust to lower mist. 40%-60% works best<br>2. Open door and windows, or change to a larger room |
Air inlet is blocked | Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall. Point nozzle away from wall or window | |
Low indoor temperature leads to liquefaction | Raise the room temperature to 25°C / 77°F | |
Poor humidification | Mist level is set too low for the room size | 1. Adjust to maximum mist<br>2. Close door or windows to reduce air ventilation, or change to a smaller room |
Air inlet is blocked | Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall | |
Low indoor temperature leads to liquefaction | Raise the room temperature to 25°C / 77°F | |
White dust appears or the black coating on the base flakes off | Tap water may contain too much minerals | Replace with filtered or distilled water |
Strange Odor | Clean the unit | 1. Clean the humidifier as instructed<br>2. Leave the empty and opened water tank in a cool place for 12 hours without the tank cap attached |
Strange water noise | Water is going down to the water reservoir | This is normal while it is working |
Humidifier is getting too hot | Unit works for too long | Power off and place in a well-ventilated place for 10 minutes |
Pros & Cons
Pros
- Quiet and efficient ultrasonic technology
- 360-degree rotatable nozzle for directed mist output
- Large 4-liter water tank for up to 24 hours of continuous use
- Easy-to-clean design and low maintenance
- LED night light with adjustable brightness
- Humidity level detection and intelligent auto mode
Cons
- May not be suitable for larger rooms
- Replacement water tanks may be expensive
WARRANTY
This product is covered with Homech product and labor warranty for 12 months from the date of its original purchase. You will be given a warranty extension to 18 months if the product is registered on our website https://www.homech.net
Customer Reviews
"This humidifier is amazing! It is so quiet and efficient, and the mist output is perfect. I love the adjustable LED night light and the fact that it is so easy to clean. Highly recommend!" - Sarah L.
"I've had this humidifier for a few months now and it has been a lifesaver. I wake up with clear sinuses and my skin is no longer dry. It's also very easy to use and maintain." - John S.
"I was a little skeptical about the price, but this humidifier is worth every penny. It's so quiet and the mist output is perfect. I would highly recommend this to anyone looking for a high-quality humidifier." - Amy T.
Faqs
How should the water tank be filled?
Which humidifier should I clean how often?
When the tank is full, how long can the humidifier run?
How can I change the production of mist?
When the humidifier runs, does it make noise?
Which kind of water is ideal for the Homech Ultrasonic Cool Mist Humidifier?
If there's no mist coming from the humidifier, what should I do?
Is it okay to use the humidifier near kids and pets?
When not in use, how should I store the humidifier?
What is the Homech HM-AH001's warranty period?
Leave a Comment