Homech Ultrasonic Cool Mist Humidifier HM-AH003 User Manual
Content
Introducing the Homech Ultrasonic Cool Mist Humidifier HM-AH003
We will learn about the Homech Ultrasonic Cool Mist Humidifier HM-AH003 in this article. With its spacious 4L water tank, this humidifier can produce a continuous mist for up to 60 hours, enhancing the comfort and quality of the air in your house. Because of its whisper-quiet functioning due to its ultrasonic technology, it is ideal for use in workplaces, nurseries, and bedrooms. The HM-AH003 is the perfect option for maintaining proper humidity levels in medium- to large-sized rooms because of its adjustable mist settings and easy-to-clean design. Make your home more comfortable by using the Homech. The HM-AH003 is currently available for purchase and has an estimated retail price of $30.00.
PACKAGE CONTENTS
- 1 x Home Humidifier (Model: HM-AH003)
- 1 x Cleaning Brush
- 1 x Dustproof Sponge
- 1 x Thank You Card
- 1 x User Manual
PRODUCT DIAGRAM
- Nozzle
- Water Tank
- Water Level Window
- Tank Cap
- Water Inlet
- Handle
- LED Indicator
- Control Knob
- Base
SPECIFICATIONS
Model | HM-AH003 |
Operating Voltage | AC 100-120V 50 / 60Hz |
Rated Power | Min: 15W Max: 25W |
Water Tank Capacity | 6.0L / 1.59Gal |
Mist Output | Min: 60ml/h Max: 300ml/h |
Working Time on a Full Tank | 20-100h |
Recommended Room Size | 20-40m² / 215-430ft² |
Noise | <27dB (A) |
Dimensions | 251 x 167 x 412mm / 9.9 x 6.6 x 16.2in |
Net Weight | 1775g/62.6oz |
Detailed Description
A flexible and user-friendly device, the Homech Ultrasonic Cool Mist Humidifier HM-AH003 is ideal for adding moisture to the air in your house or place of business. The HM-AH003, which has a 3L water tank and can run for up to 12 hours on a single fill, is a great option for usage in living rooms, bedrooms, and other large places. In order to suit your individual demands, you can also alter the mist level on the gadget.
The HM-AH003 is a remarkable device because of its ultrasonic technology, which assures exceptional energy efficiency and almost silent operation. To further increase safety and peace of mind, the HM-AH003 also features an automated shut-off feature that switches the device off when the water level is low.
Control Panel
Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidifier is ready for use.
- Rotate the control knob clockwise to the ON position. The blue LED indicator will light up indicating that the humidifier has been turned on.
- Keep rotating the control knob clockwise to increase the mist level.
- Rotate the control knob counterclockwise to decrease the mist level.
- Rotate the control knob counterclockwise to the OFF position to turn off the humidifier.
The LED indicator will turn off. The fan will work for another 3 minutes to dry the mist tube.
Note:
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist output as needed.
Light Control
- Press the Light Button to turn on / off the night light.
- Press and hold the Light Button for 1.5 seconds to turn on / off the tank light.
Low Water Protection: Auto Shut-off the Humidifier
When there is not enough water inside the water reservoir, the humidifier will stop misting and The LED indicator will become red. It is designed for safety concerns to prevent the humidifier from possibly overheating and damaging the atomizer.
OPERATIONS AND FUNCTIONS
Add Water
- Remove the nozzle and turn the water tank upside down.
- Remove the tank cap and fill the tank with clean and cool water only.
- Attach the tank cap and place the tank back onto the base.
Make sure it fits together securely so that water can go from the tank to the reservoir. Put the nozzle back on.
NOTE
- If tap water is too hard, it is recommended to use filtered or distilled water to avoid white dust. DO NOT use hot water.
- DO NOT add any essential oils or medicinal tablets into the water tank.
- DO NOT add water into the base or through the nozzle.
- DO NOT move the humidifier while the water tank is full of water to avoid leakage or base overfilling.
CLEANING AND MAINTENANCE
Caution
- DO NOT submerge the base in water.
- Make sure water does not enter the base through the air outlet, air inlet, or the control knob and light button.
DO NOT wash any part of this humidifier in the dishwasher which will damage the humidifier and void the warranty.
Daily Maintenance
Turn off the humidifier, and unplug it from the power source. Drain water from the tank, reservoir, and base.
Weekly Maintenance
- To properly clean your humidifier, we recommend you remove the scale and disinfect the humidifier separately.
- DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of bleach per gallon of water to avoid damaging your humidifier.
- Please make sure the rubber ring & rubber cap & spring on the tank cap is installed properly after cleaning to avoid water leakage. Please refer to the diagram on page 13.
Scale Removal Instructions
- Turn off and unplug the humidifier. Remove the nozzle.
- Remove the water tank from the base. Remove the tank cap. Make sure that the white sealing ring does not come off. Drain water from the water tank and base. Remove any accessories and set them aside.
- Fill the water tank half full. Add 1 teaspoon of undiluted distilled white vinegar. Attach the tank cap and shake the tank for 15 seconds.
- Place the tank onto the base. The vinegar solution will enter the water reservoir to loosen mineral buildup (scale) on the atomizer, water floater, and the bottom of the water tank. Set it still for 15-20 minutes.
- Uncap the tank cap and drain the solution. Wipe the atomizer and floater with a soft cloth to remove loosened mineral deposits.
Rinse both the water reservoir and water tank until the smell of vinegar (for scale removal) or bleach solution (for disinfecting, see below) is gone.
Disinfecting Instructions
- Follow steps 1-2 of the previous section on scale removal.
- Fill the water tank half full. Add ½ tsp of bleach. Place the tank cap back on. Swish the solution around in the tank. Place the tank on the base. The bleach solution will enter and disinfect the water reservoir as well as the other components. Set it still for 15-20 minutes.
- Follow steps 4-6 of the previous section on scale removal to complete disinfecting the humidifier.
Clean the Dustproof Sponge
Clean the dustproof sponge (at the back of the base) with water or detergent once a month. Put it back in place after cleaning.
End-Of-Season Care and Storage
- Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season. Remove any accessories used with the humidifier and allow the humidifier and accessories to dry completely before storing.
- DO NOT store water inside the base, water reservoir, or tank.
- Pack the unit safely and store it in a cool, dry location.
SAFETY INSTRUCTIONS
The humidifier was made with safe and environmental protection materials, it has been certified and complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save these SAFETY INSTRUCTIONS before using the device. Basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons or damage to the product
BEFORE USING THE HUMIDIFIER
- Please check the cord for any signs of damage. Do not use the humidifier if the cord has been damaged.
DO NOT place this humidifier in wet environments
Please always keep the humidifier out of reach of patients & children & pets.
- Please always place the unit on a smooth, fiat, lint-free, non-metallic, waterproof, and level surface and keep it away from direct sunlight.
Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall, other appliances, or wooden furniture.
WHEN USING THE HUMIDIFIER
- DO NOT plug the unit with wet hands.
DO NOT direct the mist nozzle against the wall.
- DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury.
DO NOT clean the unit while it is connected to a power source or while it is on.
- DO NOT move or tilt the humidifier while it is in operation.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
AFTER USING THE HUMIDIFIER
- Always disconnect from a power source by pulling out the plug when not in use.
The humidifier requires regular cleaning. Please refer to, and follow the Cleaning and Maintenance instructions.
- DO NOT clean the humidifier right after turning it off if the humidifier is warm to the touch.
Allow the humidifier to completely cool down before cleaning. DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier.
Doing so will void your warranty.
TROUBLESHOOTING
- If the information listed in the troubleshooting guide can’t solve your problem, please email us for help.
- Failure to keep this unit clean from mineral deposits may affect the operation of this unit.
Customer failure to follow these instructions may void the warranty.
Problem | Possible Cause | Solution |
Failed to turn on the unit. |
Unit not plugged in. | Ensure unit is properly plugged in. |
No power from power outlet. | Try another power outlet. | |
Waterless indicator is constantly on. |
No water in the water reservoir. | Ensure the 1 spring is secured properly to the tank allowing water to pass through to the base. |
3 Water floater get stuck. | Adjust the 3 water floater to a horizontal position and make sure it can rise up with water . |
The unit is on but no mist or little mistis produced. | Not enough water inside the tank. |
Refill and reinstall the water tank. |
Mist level is set too low. | Adjust to larger mist output. | |
The base might be overfilled. | Remove the tank, empty the base and place back the filled tank on the empty base. | |
Mineral buildup on atomizer. | Put your handtowards the nozzleand feel if there is air coming out. If yes, clean thewater scale onthe atomizer as instructed(p10). | |
Tank leakage. |
Tank may be damaged. | Check for possible cracks in the tank. Ask for a replacement if it is damaged. |
Tank cap is not tightened securely. |
Tighten the tank cap. | |
2 Rubber ring was not installed on tank cap. | Check the tank cap for rubber ring, contactus if any is missing. | |
1 Spring get stuck. | Ensure the 1 spring is secured properly to the tank allowing water to pass through to the base. | |
Mist height is low, damping surrounding desk or floor. Condensation forms around humidifier or on windows and walls. |
Mist level is set too high for the room size. |
|
Air inlet is blocked. | Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall. Point mist outlet away from wall or window. | |
Low indoor temperature leads to liquefaction. | Raise the room temperature to 25°C/77°F. |
Poor humidification. |
Mist level is set too low for the room size. | 1-1. Adjust to maximum mist output. 1-2. Close door or windows to reduce air ventilation, or change to a smaller room. |
Air inlet is blocked. | Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall. | |
Low indoor temperature leads to liquefaction. | Raise the room temperature to 25°C/77°F. | |
White dust appears / Black coating in the base flakes off. |
Tap water may contain too much minerals. | Replace with filtered or |
Strange odor. |
Unit needs to be cleaned. | Clean the humidifier as instructed. |
Leave the empty water tank open in a cool place for 12 hours without the water tank cap attached. | ||
Strange water noise. | Water is going down to the water reservoir. | This is normal while it is working. |
Humidifier is getting too hot. |
Unit works long hours. | Power off and place in a well-ventilated place for 10 minutes. |
Pros & Cons
Pros
- Ultrasonic technology for quiet and efficient operation
- Large water tank for extended use
- Adjustable mist level for customized humidification
- Automatic shut-off for added safety
- Sleek and modern design
Cons
- May require regular cleaning to maintain optimal performance
- May not be suitable for use in very large spaces
Customer Reviews
Customers who have purchased the Homech Ultrasonic Cool Mist Humidifier HM-AH003 have raved about its performance and ease of use. Many have noted that the device is extremely quiet, making it an excellent choice for use in bedrooms and other quiet spaces. Others have praised the device for its large water tank and adjustable mist level, which allow for extended use and customized humidification.
However, some customers have noted that the device may require regular cleaning to maintain optimal performance, and that the mist output may be lower than expected in very large spaces. Overall, though, the HM-AH003 has received overwhelmingly positive reviews and is highly recommended for anyone looking for a high-quality and affordable humidifier.
WARRANTY
This product is covered with a Home product and labor warranty for 12 months from the date of its original purchase. You will be given a warranty extension of 18 months if the product is registered on our website http://www.homech.net/ Any defective part will be, at the discretion of SUNVALLEYTEK INTERNATIONAL INC., repaired or replaced at no charge if the appliance has not been tampered with and has been used according to these printed directions.
Faqs
What are the main characteristics of the HM-AH003 Homech?
How should the water tank be filled?
Which humidifier should I clean how often?
Which kind of water is ideal for the humidifier?
When the humidifier runs, does it make noise?
Is it possible to use the humidifier in big spaces?
How can I determine when to top out the water tank?
Is cleaning the humidifier simple?
If there's no mist coming from the humidifier, what should I do?
Does Homech offer a guarantee for the Homech?
Leave a Comment