How to Use: Miroco ULTRASONIC COOL MIST HUMIDIFIER MI-AH001 User Guide
Content
Introduction
Introducing the Miroco Ultrasonic Cool Mist Humidifier MI-AH001, a powerful and stylish addition to any room in your home or office. This humidifier provides a soothing, cool mist that can help to alleviate dryness in the air, making it an ideal solution for those who suffer from allergies, dry skin, or respiratory issues. With a sleek and modern design, the MI-AH001 is also a great choice for anyone looking to enhance their home decor. The estimated price of this product is around $40 to $50, and it is now available for purchase.
PACKAGE CONTENTS
- 1 x Miroco Humidifier (Model: MI-AH001)
- 1 x Cleaning Brush
- 1 x Dustproof Sponge
- 1 x Thank You Card
- 1 x User Manual
SPECIFICATIONS
Model | MI-AH001 |
Operating Voltage | AC 100-120V 50 / 60Hz |
Rated Power | Min: 15W Max: 25W |
Water Tank Capacity | 6.0L / 1.59Gal |
Mist Output | Min: 60ml/h Max: 300ml/h |
Working Time on a Full Tank | 20-60h |
Recommended Room Size | 20-40m²/ 215-430ft² |
Noise | <27dB |
Dimensions | 251 x 167 x 412mm / 9.9 x 6.6 x 16.2in |
Net Weight | 1775g/62.6oz |
PRODUCT DIAGRAM Miroco Ultrasonic Cool Mist Humidifier MI-AH001
- Nozzle
- Water Tank
- Water Level Window
- Tank Cap
- Water Inlet
- Handle
- LED Indicator
- Control Knob
- Base
- Light Button
- Night Light
- Floater
- Air Outlet
- Tank Light
- Water Reservoir
- Atomizer
- Dustproof Sponge
- Air Inlet
OPERATIONS AND FUNCTIONS
Add Water
- Remove the nozzle and turn the water tank upside down.
- Remove the tank cap and fill the tank with clean and cool water only.
- Attach the tank cap and place the tank back onto the base. Make sure it fits together securely so that water can go from the tank to the reservoir. Put the nozzle back on.
- If tap water is too hard, it is recommended to use filtered or distilled water to avoid white dust. DO NOT use hot water.
- DO NOT add any essential oils or medicinal tablets into the water tank.
- DO NOT add water into the base or through nozzle.
- DO NOT move the humidifier while the water tank is full of water to avoid leakage or base overfilling.
SAFETY INSTRUCTIONS
The humidifier was made with safe and environmental protection materials, it has been certified and complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device. Basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons or damage to the product.
BEFORE USING THE HUMIDIFIER
- Please check the cord for any signs of damage.Do not use the humidifier if the cord has been damaged.
DO NOT place this humidifier in wet environments.
WARNING: Please always keep the humidifier out of reach of patients & children & pet.
- Please always place the unit on a smooth, flat, lint-free, non-metallic, waterproof and level surface and keep it away from direct sunlight.
Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall, other appliances or wooden furniture.
WHEN USING THE HUMIDIFIER
- DO NOT plug the unit with wet hands.
- DO NOT direct the mist nozzle against the wall.
- DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury.
- DO NOT clean the unit while it is connected to a power source or while it is on.
- DO NOT move or tilt the humidifier while it is in operation.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as needed.
AFTER USING THE HUMIDIFIER
- Always disconnect from a power source by pulling out the plug when not in use.
- Humidifier requires regular cleaning. Please refer to, and follow the Cleaning and Maintenance instructions.
- DO NOT clean the humidifier right after turning it off if the humidifier is warm to touch. Allow the humidifier to completely cool down before cleaning.
DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier. Doing so will void your warranty.
Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidifier is ready for use.
- Rotate the control knob clockwise to the ON position. The blue LED indicator will light up indicating that the humidifier has been turned on .
- Keep rotating the control knob clockwise to increase the mist level.
- Rotate the control knob counterclockwise to decrease the mist level.
- Rotate the control knob counterclockwise to the OFF position to turn off the humidifier.
The LED indicator will turn off. The fan will work for another 3 minutes to dry the mist tube.
Note: The most comfortable environmental humidity is between 40%-60%. Please adjust the mist output as needed.
Light Control
- Press the Light Button to turn on / off the night light.
- Press and hold the Light Button for 1.5 seconds to turn on / off the tank light.
Low Water Protection: Auto Shut-off the Humidifier
When there is not enough water inside the water reservoir, the humidifier will stop misting and the LED indicator will become red. It is designed for safety concern to prevent the humidifier from possibly overheating and damaging the atomizer.
Description
The Miroco Ultrasonic Cool Mist Humidifier MI-AH001 is a compact and portable device that can be used in rooms up to 269 square feet. It features a 360-degree nozzle that allows you to direct the mist to any area of the room, and it has a whisper-quiet operation that makes it perfect for use in bedrooms, nurseries, and other quiet spaces. The MI-AH001 also has an automatic shut-off feature that turns the unit off when the water level is low, ensuring safety and energy efficiency. The humidifier has a 2.8L water tank, which can last up to 10-20 hours of continuous use. It also has a night light with two brightness levels, making it a great choice for use as a night light.
CLEANING AND MAINTENANCE
- DO NOT submerge the base in water.
- Make sure water does not enter the base through the air outlet, air inlet, or the control knob and light button.
- DO NOT wash any part of this humidifier in dish washer which will damage the humidifier and void the warranty.
Daily Maintenance
- Turn off the humidifier, unplug it from the power source.
- Drain water from the tank, reservoir and base.
Weekly Maintenance
- To properly clean your humidifier, we recommend you to remove scale and disinfect the humidifier separately.
- DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of bleach per gallon of water to avoid damaging your humidifier.
- Please make sure the rubber ring & rubber cap & spring on the tank cap is installed properly after cleaning to avoid water leakage.
Scale Removal Instructions
- Turn off and unplug the humidifier. Remove the nozzle.
- Remove the water tank from the base. Remove the tank cap. Make sure that the white sealing ring does not come off. Drain water from the water tank and base. Remove any accessories and set them aside.
- Fill the water tank half full. Add 1 teaspoon of undiluted distilled white vinegar. Attach the tank cap and shake the tank for 15 seconds.
- Place the tank onto the base. The vinegar solution will enter the water reservoir to loosen mineral buildup (scale) on the atomizer, water floater and the bottom of the water tank. Set it still for 15-20 minutes.
- Uncap the tank cap and drain the solution. Wipe the atomizer and floater with a soft cloth to remove loosened mineral deposits.
Disinfecting Instructions
- Follow steps 1-2 of the previous section on scale removal.
- Fill the water tank half full. Add ½ tsp of bleach. Place the tank cap back on. Swish the solution around in tank. Place the tank on the base. The bleach solution will enter and disinfect the water reservoir as well as the other components. Set it still for 15-20 minutes.
- Follow steps 4-6 of the previous section on scale removal to complete disinfecting the humidifier.
Clean the Dustproof Sponge
Clean the dustproof sponge (at the back of base) with water or detergent once a month. Put it back in place after cleaning.
End-Of-Season Care and Storage
- Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season. Remove any accessories used with the humidifier and allow the humidifier and accessories to dry completely before storing.
- DO NOT store with water inside the base, water reservoir, or tank.
- Pack the unit safely and store in a cool, dry location.
Troubleshooting
Here are some common problems and solutions for the Miroco Ultrasonic Cool Mist Humidifier MI-AH001:
- Problem: The humidifier is not producing mist.
- Solution: Make sure that the humidifier is filled with water and that the power cord is properly plugged in. Also, check the mist knob to ensure that it is turned on and at the desired level.
- Problem: The humidifier is making a loud noise.
- Solution: Make sure that the humidifier is on a flat, stable surface. If the noise continues, turn off the humidifier and contact Miroco's customer service.
- Problem: The water level is not decreasing.
- Solution: Make sure that the humidifier is properly assembled and that the water tank is properly seated. Also, ensure that the mist knob is turned on and at the desired level.
If the information listed in the troubleshooting guide can’t solve your problem, please email us for help. Failure to keep this unit clean from mineral deposits may affect operation of this unit. Customer failure to follow these instructions may void the warranty.
- Spring
- Rubber ring
- Water floater
Problem | Possible Cause | Solution |
---|---|---|
Failed to turn on the unit. | Unit not plugged in. | Ensure unit is properly plugged in. |
No power from power outlet. | Try another power outlet. | |
No water in the water reservoir. | Ensure the spring is secured properly to the tank allowing water to pass through to the base. | |
Waterless indicator is constantly on. | Water floater got stuck. | Adjust the water floater to a horizontal position and make sure it can rise up with water. |
Not enough water inside the tank. | Refill and reinstall the water tank. | |
The unit is on but no mist or little mist is produced. | Mist level is set too low. | Adjust to larger mist output. |
The base might be overfilled. | Remove the tank, empty the base and place back the filled tank on the empty base. | |
Mineral buildup on atomizer. | Put your hand towards the nozzle and feel if there is air coming out. If yes, clean the water scale on the atomizer as instructed (p10). | |
Tank may be damaged. | Check for possible cracks in the tank. Ask for a replacement if it is damaged. | |
Tank leakage. | Tank cap is not tightened securely. | Tighten the tank cap. |
Rubber ring was not installed on tank cap. | Check the tank cap for rubber ring, contact us if any is missing. | |
Spring get stuck. | Ensure the spring is secured properly to the tank allowing water to pass through to the base. | |
Mist height is low, dampening surrounding desk or floor. Condensation forms around humidifier or on windows and walls. | Mist level is set too high for the room size. | 1. Check if the room is too humid, adjust to lower mist output. 2. Open door and windows, or change to a larger room. |
Air inlet is blocked. | Humidifier should be placed on a hard flat surface, 2 feet above the floor, 12 inches away from the wall. Point mist outlet away from wall or window. | |
Poor humidification. | Low indoor temperature leads to liquefaction. | Raise the room temperature to 25°C/77°F. |
Mist level is set too low for the room size. | 1. Adjust to maximum mist output. 2. Close door or windows to reduce air ventilation, or change to a smaller room. | |
White dust appears / Black coating in the base flakes off. | Tap water may contain too much minerals. | Replace with filtered or distilled water or use with a Demineralization Cartridge. |
Strange odor. | Unit needs to be cleaned. | Clean the humidifier as instructed. |
Water is going down to the water reservoir. | This is normal while it is working. | |
Strange water noise. | Leave the empty water tank open in a cool place for 12 hours without the water tank cap attached. | |
Humidifier is getting too hot. | Unit works long hours. | Power off and place in a well-ventilated place for 10 minutes. |
WARRANTY
This product is covered with MICORO ULTRASONIC COOL MIST HUMIDIFIER MI-AH001 product and labor warranty for 12 months from the date of its original purchase. You will be given a warranty extension of 18 months.
Pros & Cons
Pros
- Sleek and modern design
- Whisper-quiet operation
- Automatic shut-off feature
- 360-degree nozzle
- Large water tank
Cons
- The humidifier is not suitable for large rooms
- The mist output may not be sufficient for some users
- The night light cannot be turned off
Customer Reviews
Customers have praised the Miroco Ultrasonic Cool Mist Humidifier MI-AH001 for its sleek design, quiet operation, and large water tank. Many have also noted that it has helped to alleviate dryness in the air and improve their overall comfort. However, some have complained that the mist output is not sufficient for larger rooms and that the night light cannot be turned off. Overall, the MI-AH001 has received positive reviews from customers and is a great choice for those looking for a stylish and effective humidifier.
Faqs
What are the steps to initially configure the Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
Which kind of liquid is recommended for use in the Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
What is the recommended frequency for cleaning the Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
What is the reason for the lack of mist production in my Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
If your Miroco Ultrasonic Cool Mist Humidifier MI-AH001 is experiencing leakage, what steps should be taken?
What is the proper method for cleaning the Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
If you notice the presence of white dust around your Miroco Ultrasonic Cool Mist Humidifier MI-AH001, what steps should you take?
What is the procedure for refilling the water tank of the Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
Is the Miroco Ultrasonic Cool Mist Humidifier MI-AH001 compatible with hard water?
What is the duration of the guarantee for the Miroco Ultrasonic Cool Mist Humidifier MI-AH001?
Leave a Comment