Rossmax Digital Medical Thermometer TG120 Instruction Manual

cover-image

Content

Rossmax Digital Medical Thermometer TG120

Introducing the he Rossmax Digital Medical Thermometer TG120 provides quick and accurate temperature readings, making it an essential tool for monitoring health at home. Designed for oral, rectal, and axillary use, this thermometer features a clear LCD display for easy reading and a beeping alarm to indicate when the measurement is complete. With a compact design for portability and convenience, the Rossmax TG120 is priced at approximately $15, offering an affordable solution for effective temperature monitoring.

The Digital Medical Thermometer provides quick, highly accurate reading over the human body temperature range. Please read the instructions completely first.
The quality of the thermometer has been verified and conforms to the provisions of the EC council directive 93/42/EEC(Medical Device Directive) Annex I essential requirements and applied harmonized standards. EN 12470-3: 2000 /A1: 2009 Clinical thermometers-Part 3: Performance of compact electrical thermometers (non-predictive and predictive) with maximum device.

Attention: Consult the accompanying documents. Please read this manual carefully before use. Please be sure to keep this manual.

introduction_rossmax_digital_medical_thermometer_tg120.png

Specifications

Measurement Range

32.0ºC~42.9ºC (89.6~109.2ºF)

Display

LCD 3 1/2 digits with ºC

Display resolution

0.1ºC or 0.2ºF

Accuracy

±0.1°C35.5°C~42.0°C (±0.2°F 95.9°F~107.6°F)

±0.2°C under 35.5°C or over 42.0°C (±0.4°F under95.9°F or over 107.6°F)

at standard room temperature 25.0°C(77.0°F)

Memory

For storing thelast measured value

Battery

One 1.5 V DC. button size battery (SR41 or LR41)

Battery Life

Approx.1500 times operation or 1 year with 1-2 measurement per day including standby mode.

Dimension

TG100 : 12.2x2.0x1.25cm TG120 :12.2x2.0x1.1cm

Weight

TG100 : 8 grams including battery TG120 : 9.5 gramsincluding battery

Alarm

beep sounds(beep-beep-beep10 times)

when peak temperature is reached

Environmentalfor

using

Temperature: 5~40ºC (41ºF~104ºF)

Humidity: ≤95%RH

Storage and trans-portation condition

Temperature: -25~55ºC (-13ºF~131ºF)

Humidity: ≤95%RH

Accessories

battery, carrycase, instruction manual

Safety classification  Type B Applied Part

How to Use

  1. Push the On/Off button by the display window. The display will read for 2 seconds and beep sound will be heard.
  2. Releasing the on/off button, last measured temperature will be shown for about 2 seconds. Then shows the self-test temperature 37.0°C(98.6°F),and then Lo°C (Lo°F) displays.
  3. Wipe or dip the probe with alcohol for disinfection. Position the probe in oral, rectal or axillary site.
  4. Once the degree sign °C ( °F) on the display has stopped flashing (usually within 30 to 60 seconds), an Beep signal will sound for approx. 10 times, the measured temperature is shown on LCD window. The temperature reading will not change after the unit is removed from testing position. If the temperature <37.8°C(100.0°F ), the buzzer will alarm “Bi—Bi—Bi—Bi—”. If the temperature ≥ 37.8°C (100.0°F), the buzzer whose frequency is higher will alarm “Bi-Bi-Bi—-Bi-Bi-Bi–” about 10 times rather than”Bi—Bi—Bi—Bi—”
  5. The unit will automatically turn off in 10 minutes for energy saving. However, to prolong the life of the battery, it is suggested to press the On/Off button to turn the unit off once the measurement is done.
  6. Please dispose of any used battery and the thermometer according to the local regulations.

Note: After step 2, if the room temperature is greater than 32.0°C (89.6°F ). it will be displayed the room temperature. Note: Usage of the probe cover may result in a 0.1°C(0.2°F) difference from actual temperature.

Note: To clean the probe before and after using the thermometer to ensure an accurate reading and avoid cross contamination approximately.

Oral Use

  • Place the probe well under the patient’s tongue. Confirm the patient to keep his mouth closing for about 1 minute.
  • Do not drink hot or cold fluids, exercise, and smoke or perform other activities prior to a reading. These activities will raise or lower temperature readings when compared to your normal, average temperature.

Axillary Use

  • Tightly place probe in the patient’s armpit for about 1~5 minutes. *Please ensure the close contact between the probe and the armpit of the baby or children.

Rectal Use

Always uses probe cover when taking rectal measurements.

  1. Commonly used for young children when it is difficult to take an oral or axillary temperature.
  2. Lubricate with a water-soluble gel. Do not use petroleum jelly.
  3. Gently insert the probe tip no more than 1.5-2 cm into the rectum for about 1 minute. Do not force the tip into the rectum if resistance is encountered.
  4. Disinfect the thermometer after use. Refer to “cleaning and disinfection“section.

ºC /ºF Switchable

Temperature readings are available in the Fahrenheit or Celsius scale (°C / °F; located in the right of LCD.) With the unit off, press and hold the On/Off Button for approximately 4 seconds to change the current setting.

Description

The Rossmax Digital Medical Thermometer TG120 is engineered with user convenience in mind. The device features a large LCD display that clearly shows the temperature reading, ensuring easy readability. It comes with a soft, flexible probe that is comfortable to use orally, rectally, or under the arm. The thermometer also includes a protective case for safe storage and transport. Additionally, it has a fever alert function that indicates high temperatures, making it easier to monitor health status. The Rossmax TG120 is designed to be hygienic and easy to clean, making it suitable for multiple users.

Battery Replacement

battery_replacement_rossmax_digital_medical_thermometer_tg120.png
  1. When the battery_replacement_rossmax_digital_medical_thermometer_tg380.png appears on the upper right corner of the LCD, the battery is exhausted and needs replacement.
  2. Pull the battery cover off in the direction shown below.
  3. Pull out the battery with a sharp objects such as pen. Keep exhausted battery from reaching by the children.
  4. Place a new 1.5V D.C. button size battery type SR41 or LR41 or equivalent in the chamber with positive side faced up and negative side faced down.
  5. Install the battery cover back.

Display on the LCD

M: Last measured temperature

Display on the LCD

When thebattery_replacement_rossmax_digital_medical_thermometer_tg380.png appears on the upper right corner of the LCD, the battery is exhausted and needs replacement.

Setup Guide

To set up and operate the Rossmax Digital Medical Thermometer TG120, follow these steps: 

  • Insert Batteries: Place the provided batteries into the battery compartment. 
  • Choose Measurement Mode: Select the desired measurement mode (oral, rectal, or underarm). 
  • Take Reading: Gently insert the probe into the chosen area (mouth, rectum, or underarm) until the beep sounds. 
  • Read Temperature: The temperature will be displayed on the LCD screen. 
  • Store Results: The device will automatically store the last 20 readings for future reference.

Cleaning and Disinfection

  1. Clean the unit by wiping it with a dry cloth and sterilize the probe with ethyl alcohol.
  2. Don’t let the unit contact any chemical thinner.
  3. Not waterproof. Do not soak the display in water. Only the probe is waterproof.

Caution

  • Do not bend or drop the thermometer. It is not shockproof.
  • Do not boil probe for disinfect.
  • Do not store the unit under direct sunlight, at a high temperature, in high humidity or dust. Neither store the unit under the sunlight, nor at the high temperature or humidity.
  • Do not disassemble. See BATTERY REPLACEMENT to replace battery.
  • Avoid strong electromagnetic interference such as microwave ovens and cell phones.
  • Please be noticed to keep the probe dry before putting the thermometer into the carry case.
  • The thermometer contains small parts (battery, etc.) that can be swallowed by children. Therefore never leave the thermometer unattended to children.
  • The thermometer should be cleaned after measurement no matter the probe cover has been installed or not.
  • Battery should not be charged or placed into extreme heat as it may explode.
  • Do not use the thermometer in ear. Intended use is for oral, axillary and rectal measurement.
  • Use of the probe cover may result in a 0.1ºC(0.2ºF) discrepancy from actual temperature.
  • Remove battery from the thermometer when not in operation for a long time.
  • If the unit is stored in an extreme environment before measurement, please make sure it has been firstly adapted in the room temperature, so that the unit can be measured normally.
  • Please note that this is a home healthcare product only, and it is not intended to serve as a substitute for the advice of a physician or medical professional.
  • Do not use this device for diagnosis or treatment of any health problem on disease. Measurement results are for reference only. Contact your physician if you have or suspect any medical problems. Do not change your medications without the advice of your physician or healthcare professional.
  • This device may not meet its performance specification if stored or used outside temperature and humidity ranges specified in specifications.
  • If this device is used according to the operations instruction, periodic re-calibration is not required. If you still have questions, please send the device to dealers.
  • Please do not dispose of the product in the household waste at the end of its useful life. Disposal can take place at your local retailer or at appropriate collection points provided in your country.
  • This device is for oral, axillary and rectal use only.
  • High, prolonged fever requires medical attention especially for young children. Please contact your physician.
  • For save reason, during children’s temperature measurement, please keep them from crying, walking, talking and any related dangerous activities.

EMC guidance and manufacturer’s declaration

Guidance and manufacturer’s declaration-electromagnetic emissions

The TG100/TG120 is intended for use in the electromagnetic environment specified below.

The customer or the userof the TG100/TG120 should assure thatit is usedin such an environment.

Emission test

ComplianceElectromagnetic environment-guidance
RF emissions CISPR 11Group 1

The TG100/TG120 uses RF energy only for its internal func- tion. Therefore, its RF emissions are very low and are not likely to causeany interference in nearby electronic equip- ment.

RF emissions CISPR 11Class B

The TG100/TG120 is suitablefor usein all establishments, including domestic establishments and those directly con- nected to thepublic low-voltage powersupply network that supplies buildings used for domestic purposes.

Harmonic emissions IEC 61000-3-2Not applicable
Voltage fluctuations/flicker emissionsIEC 61000-3-3Not applicable

Guidance and manufacturer’s declaration-electromagnetic immunity

The TG100/TG120 is intended for use in the electromagnetic environment specified below.

The customer or the userof the TG100/TG120 should assure thatit is usedin such an environment.

Immunity testIEC 60601 test level

Compliance level

Electromagnetic environment-guidance

Electro-

static discharge(ESD) IEC61000-4-2

+ 6 kV contact

+ 8 kV air

+ 6 kV contact

+ 8 kV air

Floors shouldbe wood, concrete or ceramic tile. If floors are covered with synthetic mate- rial, the relative humidity should be at least 30%

Electrical fast transient/burst IEC61000-4-4

+ 2kV for power supply lines

+ 1kV for input/ output lines

Not applicable

Not applicable

Mains power quality should be thatof a typi- cal commercial or hospital environment.

Surge IEC 61000-4-5

+ 1kV line(s)to line(s)

+ 2kV line(s) toearth

Not applicable Not applicable

Mains power quality should be thatof a typi- cal commercial or hospital environment.

Voltage Dips, short interruptions and voltage variations on power supply inputlines IEC 61000-4-11

<5% UT(>95%

dip in UT) for 0,5cycle

40% UT(60% dip

in UT) for 5 cycles

70% UT(30% dip

in UT) for 25 cycles

<5% UT(>95%

dip in UT) for 5 s

Not applicable

Not applicable Not applicable Not applicable

Mains power quality should be thatof a typi- cal commercial or hospital environment. If the user of the TG100/TG120 requires continued operation during powermains interruptions, it is recommended that the TG100/TG120 be powered from an uninterruptible power supply or a battery.

Power frequency (50/60 Hz) magnetic field IEC61000-4-8

3 A/m3 A/m

The TG100/TG120 power frequency magnetic fields shouldbe at levelscharacteristic of a typical location in a typical commercial or hospitalenvironment.

NOTE UT is the a.c. mains voltage prior to application of the test level.

Guidance and manufacturer’s declaration-electromagnetic immunity

The TG100/TG120 is intended for use in the electromagnetic environment specified below.

The customer or the userof the TG100/TG120 should assure thatis used in such andenvironment.

Immunity testIEC 60601 test levelCompliance levelElectromagnetic environment-guidance

 

 

 

Portable and mobile RF communications equipmentshould be usedno closer to any partof the TG100/TG120 including cables, than the recommended separation distance calculated from theequation applicable to the frequency of the transmitter.

 

 

 

Conducted RF IEC 61000-4-6

 

 

 

3Vrms

150KHz to 80 MHz

 

 

 

 

Not applicable

Recommended separation distance:

d = 1,2 √P

d = 1,2 √P 80MHzto 800 MHzd = 2,3 √P 800MHzto 2,5 GHz

Where P is the maximum output power rating of the transmitter in watts (W)according to the trans- mitter manufacturer and d is the recommended separation distance in metres (m).

Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey.

  1. Shouldbe lessthan the compliance level ineach frequency range.

  2. Interference may occur in the vicinity of equip- ment marked with the following symbol:

Radiated RF IEC 61000-4-3

3 V/m

80MHz to 2,5 GHz

3 V/m

NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

  1. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobileradios,amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due tofixed RF transmitters, an electromagnetic site survey should be considered.If themeasured field strength in the location in which the TG100/TG120 is used exceeds the applicable RF compliance level above, the TG100/TG120 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the TG100/TG120.

  2. Over the frequency range 150 kHz to 80 MHz, field strengths should be les than 3 V/m.

Recommended separation distance between portable and mobile RF communications equipment and the TG100/TG120

The TG100/TG120 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the userof theTG100/TG120 can help prevent electromagneticinterfer- ence by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the TG100/TG120 as recommended below,according to the maximum outputpower of the communications equipment.

Rated maximum output power of transmitter W

Separation distance according tofrequency of transmitter m

150 kHz to 80 MHz d =1,2√P

80 MHz to 800 MHz d =1,2√P

800MHz to 2,5 GHz d =2,3√P

0,01

N/A

0,12

0,23

0,1

N/A

0,38

0,73

1

N/A

1.2

2.3

10

N/A

3.8

7.3

100

N/A

12

23

For transmitters rated at a maximum output power not listed above, the recommended separation dis- tance din meters (m) can be estimatedusing the equation applicable to the frequency of the transmitter, where P

The maximum outputpower rating of the transmitter in watts (W) according to the transmitter manufac- turer.

NOTE1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. v.png

Troubleshooting

Error message

Problem

Solution

troubleshooting_rossmax_digital_medical_thermometer_tg380.png

The system isnot functioning properly

Unload the battery, waitfor 1

mins and repower it.

If the message reappears, con- tact the retailer for service.

troubleshooting_of_rossmax_digital_medical_thermometer_tg380.png

(bi-bi...bi)x10

Temperature

taken is higherthan

42.9°C (109.2°F)

Take a new temperature meas-

urement after 6 sec.

troubleshooting_of_the_rossmax_digital_medical_thermometer_tg380.png

Temperature taken is lower than32°C (89.6°F)

Take a new temperature meas-

urement after 6 sec.

troubleshooting_of_the_rossmax-digital_medical_thermometer_tg380.png

Dead battery: Battery icon is flashing, can’t be measurable.

Suggest to replacethe battery.

Rossmax Digital Medical Thermometer TG120 Warranty

This instrument is covered by a 5 year guarantee from the date of purchase, batteries and accessories are not included. The guarantee is valid only on presentation of the guarantee card completed by the dealer confirming date of purchase or the receipt. Opening or altering the instrument invalidates the guarantee. The guarantee does not cover damage, accidents or non-compliance with the instruction manual. Please contact rossmax service.

Pros & Cons

Pros

  • Quick Readings: Provides fast and accurate temperature readings within seconds.
  • User-Friendly: Easy to use with clear instructions and a simple interface.
  • Multi-Mode: Can be used orally, rectally, or under the arm for versatile measurement options.
  • Affordable: Priced competitively compared to other digital thermometers on the market.
  • Memory Recall: Stores previous readings for convenient tracking of temperature history.

Cons

  • Battery Life: Batteries may need frequent replacement if used extensively.
  • Probe Sensitivity: The probe can be sensitive; improper handling may affect accuracy.
  • No Additional Features: Does not come with advanced features like Bluetooth connectivity or smartphone app integration.

Customer Reviews

Customers have generally praised the Rossmax Digital Medical Thermometer TG120 for its accuracy and ease of use. Many reviewers have noted that it is particularly useful for families with young children due to its quick response time and multi-mode functionality. However, some users have reported issues with battery life and occasional inaccuracies if not used correctly. Overall, it is highly recommended for those seeking a reliable and affordable digital thermometer.

Common complaints include occasional issues with battery life and the need for precise probe placement to ensure accurate readings.

Faqs

How do I ensure accurate readings with the Rossmax Digital Medical?

To ensure accurate readings, make sure the probe is properly placed in the chosen area (oral, rectal, or underarm). The probe tip should be clean and free from any debris. Follow the instructions provided with the device for proper use.

What is the typical response time for the Rossmax TG120?

The typical response time for the Rossmax Digital Medical Thermometer TG120 is approximately 10 seconds. This ensures that you get quick and reliable temperature readings.

Does the Rossmax Digital Medical come with any certifications?

Thermometer TG120 is FDA-cleared and CE-marked, indicating that it meets stringent quality and safety standards.

How many previous readings can the Rossmax Digital Medical Thermometerstore?

The Rossmax Digital Medical can store up to 20 previous readings, making it convenient to track temperature history.

Is the Rossmax Digital Medical Thermometer suitable for use on children?

Rossmax is suitable for use on children. It has a soft, flexible probe that is comfortable to use orally, rectally, or under the arm, making it ideal for pediatric care.

What are some common issues with the Rossmax Digital Medical Thermometer and how can they be resolved?

Common issues include no display or inaccurate readings. These can often be resolved by checking the battery placement and ensuring the probe tip is clean. If issues persist, refer to the troubleshooting guide provided with the device.

Can I use the Rossmax Digital underarm?

Yes, you can use the Thermometer TG120 underarm. However, it is less accurate compared to oral or rectal measurements and is generally recommended for adults and older children.

Is there an audio signal when using the TG120?

Yes, the Rossmax Digital Medical Thermometer emits an audio signal (beep sound) when the measurement is complete, indicating that you can read the temperature on the display.

How do I clean and maintain my Rossmax Digital Medical?

To clean and maintain your Rossmax Digital Medical Thermometer TG120, use a soft cloth and mild soap solution to wipe down the probe tip and exterior. Avoid immersing the device in water or using harsh chemicals.

What is included in the packaging of the Rossmax Digital?

The packaging typically includes the thermometer unit, protective case, batteries, user manual, and sometimes additional accessories like probe covers.