Usage: Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat User Manual
Content
Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat: Comprehensive Product Manual

Introduction to Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat
The **Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat** is a versatile 3-in-1 electrostimulation device designed for natural pain relief, muscle stimulation, and therapeutic massage. Combining TENS (Transcutaneous Electrical Nerve Stimulation), EMS (Electrical Muscle Stimulation), and massage programs with an innovative switchable heat function, this unit delivers targeted therapy for muscular aches, improved muscle performance, and deep relaxation. Ideal for home use, it suits individuals managing chronic pain, athletes recovering from workouts, or anyone seeking drug-free pain management and muscle toning solutions.
Key benefits include 70 customizable programs—15 TENS, 35 EMS, and 20 massage options—with adjustable intensity levels across two independent channels for treating multiple body areas simultaneously. The heat function offers two levels (low and high) to enhance relaxation and blood flow, making the **Beurer EM 59 Heat** stand out among TENS EMS devices. Featuring biphasic rectangular pulses (pulse length 50–450 µs, frequency 1–150 Hz), a timer, rechargeable battery, and easy-to-read display showing battery status, program number, frequency, pulse width, and intensity, it's user-friendly for all body parts.
Compact at 5.5 x 2.6 x 1.0 inches and weighing just 0.3 pounds, it includes 4 gel pads, electrodes, and a connection cable. Target users include those with back pain, arthritis, or post-injury recovery needs. Estimated price range is $80–$120, available at retailers like Amazon, Galaxus, and Beurer's official shop. This medical device (Class IIa) provides effective, non-invasive therapy for daily wellness.
DEVICE DESCRIPTION


Display (full screen)

INTENDED USE
TENS/EMS/Massage Purpose
The device is intended to treat pain using TENS technology (transcutaneous electrical nerve stimulation). This pain relief can be applied to different areas of the human body as identified in the following eight indication areas.
As a non-medical purpose, the device can also be used with EMS technology (electrical muscle stimulation) to strengthen the muscles, and for regeneration and relaxing massages.
TENS/EMS/Massage Target Group
This device is intended for self-treatment in the home, and not in professional healthcare facilities. Suitable for use by all adults suffering from pain as indicated in the indications below.
Clinical Benefits
Treatment of pain due to various causes.
Non-Clinical Benefits
- Muscle training to increase endurance and/or
- Training to support the strengthening of specific muscles or muscle groups, and to achieve the desired changes to physical proportions.
- Acceleration of muscle regeneration after intense muscular output (e.g. after a marathon).
- Improving symptoms of muscular fatigue.
- Muscle relaxation for easing muscle tension.
Indications
Use of the device is advised for:
- Back pain – pain at rest and on exertion.
- Joint pain – pain at rest and on exertion.
- Neuralgia, including phantom pain.
- Menstrual cramps.
- Pain due to circulatory disorders – pain at rest and on exertion.
- Headaches.
- Pain after musculoskeletal injuries – pain at rest and on exertion.
- Chronic pain due to various causes – pain at rest and on exertion.
Contraindications
The device must never be used near to the heart. The stimulation electrodes must not be placed on any part of the front ribcage (where the ribs and breastbone are located), and especially not on the two large pectorals. This can increase the risk of ventricular fibrillation and induce cardiac arrest (see "General warnings" section).
Do NOT use the device:
- On the skeletal skull structure, or around the mouth, throat or larynx.
- In the neck/carotid artery area.
- In the genital area.
- If you have implanted electrical devices (e.g. a pacemaker).
- If you have metal or electrical implants.
- If you use an insulin pump.
- If you have a high temperature (e.g. > 39°C).
- If you have a known or acute cardiac arrhythmia or disorders of the heart's conduction system.
- On acutely or chronically diseased (injured or irritated) skin (e.g. inflamed skin – whether painful or not, reddened skin, rashes (e.g. allergies), burns, bruises, swellings, both open and healing wounds, or post-operative scars that are healing).
- If you suffer from a seizure disorder (e.g. epilepsy).
- If you are pregnant.
- If you have cancer.
- After an operation, if strong muscle contractions could affect the healing process.
Undesirable Side Effects
- Skin irritation.
- Feeling of pressure at the electrode location.
- Slight redness, burning and pain of the skin after treatment.
- Paraesthesia.
- Discomfort.
- Sleepiness.
- Vibration of muscles.
- Tension.
- Headaches.
- Increased menstrual bleeding.
- Allergic reactions to components.
WARNINGS AND SAFETY NOTES
This device is not a substitute for medical consultation and treatment. Consult your doctor first if you are experiencing any pain or are suffering from an illness! To avoid damage to health, we strongly advise against using the digital EMS/TENS unit in the following situations:
- With implanted electrical devices (such as a pacemaker).
- In the case of metal implants.
- If you use an insulin pump.
- If you have a high temperature (e.g. > 39°C).
- If you have a known or acute cardiac arrhythmia, or disorders of the heart's impulse and conduction system.
- If you suffer from a seizure disorder (e.g. epilepsy).
- If you are pregnant.
- If you have cancer.
- After an operation, if strong muscle contractions could affect the healing process.
- The device must never be used close to the heart. The stimulation electrodes must not be placed on any part of the front ribcage (where the ribs and breastbone are located), especially not on the two large pectorals. This can increase the risk of ventricular fibrillation and induce cardiac arrest.
- On the skeletal skull structure, or around the mouth, throat or larynx.
- In the neck/carotid artery area.
- In the genital area.
Before Using the Device, Consult Your Doctor if Any of the Following Apply to You:
- Serious illnesses, in particular if you suspect or have been diagnosed with high blood pressure, a blood coagulation disorder, propensity to thromboembolic conditions or recurrent malignant growths.
- Any skin conditions.
- If you have unexplained chronic pain in any part of the body.
- Diabetes.
- If you have any sensory impairment that reduces the feeling of pain (e.g. metabolic disorders).
- If you are receiving medical treatment.
- In the event of complaints linked to stimulation treatment.
- If you suffer from persistently irritated skin due to long-term stimulation at the same electrode site.
CAUTION
Only use digital EMS/TENS units:
- On adults.
- For the purpose for which it was developed and as specified in these instructions for use. Any improper use can be dangerous.
- For external use.
- With the original accessories supplied, which can be re-ordered. Failure to do so invalidates the warranty.
PRECAUTIONS
- Always pull firmly on electrodes to remove them from the skin to prevent injuries in the unusual case of highly sensitive skin.
- Keep the device away from sources of heat (heating devices such as driers or ovens) and do not use it in close proximity (approx. 1 m) to shortwave or microwave devices (e.g. mobile phones), as doing so can result in unpleasant current peaks.
- Do not expose the device to direct sunlight or high temperatures.
- Protect the device from dust, dirt and humidity.
- Never immerse the device in water or other liquids.
- The device is suitable for self-treatment.
- For hygiene reasons, the electrodes may only be used on one person.
- If the device does not work properly, or if you feel unwell or experience pain, stop using it immediately.
- Switch off the unit or the respective channel first before removing or relocating electrodes to prevent unintentional stimulation.
- Do not modify electrodes (e.g. by cutting them), as this increases the current density, which is potentially hazardous (max. recommended output value for the electrodes is 9 mA/cm², an effective current density beyond 2 mA/cm² requires increased awareness).
- Do not use the device whilst asleep, driving a vehicle or operating machinery.
- Do not use whilst undertaking any activity where an unexpected reaction (e.g. strong muscle contractions even at low intensity) could be dangerous.
- Ensure that no metallic objects (e.g. belt buckles or necklaces) come into contact with the electrodes during stimulation. If you are wearing jewellery or have piercings in the area to be treated (e.g. a navel piercing), these must be removed before using the device. Failure to do so could result in spot burns.
Damage
- If the device is damaged, do not use it and contact your retailer or the specified Customer Services address.
- To ensure that the device functions effectively, do not drop it or dismantle it.
- Check the device for signs of wear and tear or damage. If there are such signs of wear and tear or damage or if the device was used improperly, it must be returned to the manufacturer or retailer before further use.
- Switch the device off immediately if it is faulty or not working properly.
- Never attempt to open and/or repair the device yourself. Repairs may only be carried out by Customer Services or authorised retailers. Failure to comply with this instruction will void the warranty.
- The manufacturer is not liable for damage resulting from improper or careless use.
Notes on Handling Batteries
WARNING
- Risk of explosion! Risk of fire! Failure to comply with the points mentioned can result in personal injury, overheating, leakage, venting, breakage, explosion, or fire.
- Always use the correct or supplied charging cable/charger/mains adapter for charging.
- Avoid continuous charging or overcharging. Unplug the charger when charging is complete.
- Charge the device under supervision, paying attention to any heat generated, deformation, or release of gases. If in doubt, stop charging.
- If batteries/charging cables/chargers are defective, stop using them and dispose of them properly as soon as possible (see chapter on disposal).
- Do not throw the device or batteries into a fire.
- Never forcibly discharge, heat, disassemble, open, crush, deform, encapsulate, modify, or knock the device or batteries.
- Never short-circuit batteries or the connections of the battery-powered device.
- Protect the device or batteries from direct sunlight, rain, heat, and water.
- Exposure of batteries to an environment with extremely high temperatures or an extremely low air pressure may result in explosion or leakage of flammable liquids and gases.
INITIAL USE
Before you use the EM 59 Heat for the first time, let it charge for a minimum of 4 hours. Proceed as follows.
- Connect the USB charging cable to a mains adapter (max. output 5V/2A) and the EM 59 Heat.
- Then insert the mains adapter into a suitable socket.
- Alternatively, you can charge the device using your computer/laptop. To do so, connect the device to a USB port on your PC/laptop via the USB charging cable. You cannot use the device while it is being charged.
- Turn the belt clip if required.
- Guide the connection cable plugs into the socket on the bottom of the device B1.
- Do not pull, twist or kink the cables B2.
- After the charging process is complete, apply the provided gel pads to the electrodes. First carefully remove the protective films B3. Then carefully apply the gel pads to the electrodes B4. Ensure that the edges of the gel pads do not protrude over the electrodes. Applying gel pads slightly askew will not affect their function.
USE
Starting Use
- Step 1: Look for a suitable program from the program tables (see section "Program overview").
- Step 2: Place the electrodes on the desired area for treatment (for positioning suggestions, see section "Information regarding the positioning of electrodes") and connect them to the device.
- Step 3: Press the ON/OFF button to switch on the device.
- Step 4: Press the MENU button to navigate through the TENS/EMS/Massage menus and press the ENTER button to confirm your selection.
- Step 5: Use the setting buttons to select the program number you want and press the ENTER button to confirm your selection. At the start of the stimulation treatment, the impulse intensity of both channels is set to 00 by default. No impulses are sent to the electrodes yet.
- Step 6: Use the left and right setting buttons for the respective channels to select the impulse intensity you want. The indicator for impulse intensity in the display changes accordingly. If the program is in a pause phase, the intensity cannot be increased.
- Step 7: You can activate the heat function using the heat function button. The first press of the button activates the low heat level, the second button press activates the high heat level, and the third button press deactivates the heat function.
Keylock
Locks the buttons to avoid them being pressed unintentionally.
- To activate the keylock, hold down the ENTER button until the keylock symbol is visible in the display (approx. 3 seconds).
- To deactivate the keylock, hold down the ENTER button again until the keylock symbol disappears from the display (approx. 3 seconds).
Pausing Use
You can pause the stimulation at any time by briefly pressing the ON/OFF button. To continue the stimulation, briefly press the ON/OFF button again and set the desired impulse intensity again.
HEAT
In addition to the TENS/EMS/Massage programs, the EM 59 Heat also offers two heat levels, which can be activated as required for all programs; see section "Starting use". The heat emitted by the gel pads relaxes the muscle and improves circulation. You can activate the first level of the heat function by pressing the Heat button. Then wait a moment until the temperature stops increasing. If the temperature is too low for you, you can activate the second level of the heat function by pressing the Heat button again. If you would like to deactivate the heat function, you can do so by pressing the Heat button again. If you want to use the heat function separately, without additional stimulation, proceed as follows:
- Step 1: Position the electrodes in your desired target area (see section "Information regarding the positioning of electrodes" for placement suggestions) and connect them to the device.
- Step 2: Press the ON/OFF button to switch on the device.
- Step 3: Press the Heat button to access the Heat settings.
- Step 4: Use the setting buttons to select the treatment time you want and press the ENTER button to confirm your selection.
- Step 5: Press the Heat button again to switch on the first level of the heat function. Then wait a moment until the temperature stops increasing. If the temperature is too low for you, you can activate the second level of the heat function by pressing the Heat button again.
TENS program table

EMS program table


MASSAGE program table


THERAPY MEMORY
Your device records the treatment time in the therapy memory. This allows you to record how long you have been using the device in total or for a specific period of time for your treatments. This may be helpful when consulting your doctor.
Accessing the Therapy Memory
To access the therapy memory, switch the device on using the ON/OFF button and press and hold the button for 2 seconds. The elapsed treatment time appears in the display. The top two numbers stand for minutes; the hours are shown below.
Resetting the Therapy Memory
To reset the treatment time memory (therapy memory), press and hold the button for 2 seconds. Press the MENU button to return to selecting a program, or switch the device off.
ELECTRIC CURRENT PARAMETERS
Electrostimulation devices operate with the following electric current settings, which may affect the stimulation results differently, depending on the setting.
Impulse Shape
This describes the time function of the electrical impulse. It distinguishes between monophasic and biphasic pulse currents. In monophasic pulse currents, the current flows in one direction, and in biphasic pulse currents, the electrical impulse alternates its direction. The digital EMS/TENS unit only provides biphasic pulse currents as these relieve muscles, cause little muscle fatigue, and provide safer application.
Impulse Frequency
The frequency indicates the number of individual impulses per second and is displayed in Hz (Hertz). It can be calculated by determining the cyclic value for the time period. The relevant frequency determines which types of muscle fibres react best. Slow-reacting fibres react more easily to lower impulse frequencies of up to 15 Hz, whereas fast-reacting fibres only respond from approximately 35 Hz onwards. Impulses of approx. 45–70 Hz are linked with constant tension in the muscles and quicker fatigue. Higher impulse frequencies are therefore better to use for high-speed strength and maximum power training.
Impulse Width
This indicates the duration of an individual impulse in microseconds. The impulse width therefore determines, among other things, the penetration of the electricity, where usually larger muscle mass requires a larger impulse width.
Impulse Intensity
Setting the intensity level depends on the individual sensitivity of each user and is determined by a variety of variables, such as site of application, blood supply to the skin, skin thickness and the quality of the electrode contact. The settings should be effective but should never cause an unpleasant sensation, such as pain at the site of application. While a gentle tingling indicates sufficient stimulation energy levels, any setting that causes pain should be avoided. When using the device for an extended period, you may need to adjust the intensity level, as your muscles may start to adapt to the impulse intensity.
- Cycled Impulse Parameter Variation
In many cases, it is necessary to cover the overall tissue structure at the site of application by applying several impulse parameters. In the digital EMS/TENS unit, this is achieved by the provided programs, which automatically make a cyclical impulse parameter change. This also prevents individual muscle groups at the site of application from being affected by fatigue. The digital EMS/TENS unit provides sensible default current parameter settings. With this, you can change the impulse intensity at any time during use. In 6 programs, you can also set various parameters for stimulation yourself.
CLEANING AND STORAGE
Gel Pads
- To ensure that the gel pads remain adhesive for as long as possible, clean them carefully with a damp, lint-free cloth or clean the underside of the electrodes under lukewarm, running water and pat dry with a lint-free cloth. Before cleaning with water, remove the connection cable from the device.
- Following treatment, stick the gel pads back onto the carrier foil of the gel pads.
Cleaning the Device
- After use, clean the device with a soft, slightly damp cloth. If it is very dirty, you can also moisten the cloth with a mild soapy solution.
- Do not use any chemical or abrasive cleaning agents.
Ensure that no water enters the device.
Reusing the Device
Once it has been properly prepared, the device can be used again. Preparation includes replacement of the gel pads as well as cleaning of the surface of the device using a cloth moistened with a mild soapy solution.
Storage
- Do not make sharp kinks in the connection cables and electrodes.
- Disconnect the connection cables from the electrodes.
- After use, stick the gel pads back onto the carrier foil of the gel pads.
Troubleshooting Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat
- Common issues with the **Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat** include no power, poor electrode adhesion, or uneven stimulation. If the device won't turn on, check the rechargeable battery—charge fully using the provided cable. For error indicators like low battery (displayed on screen), recharge immediately. Weak pulses often result from dried gel pads; replace with new ones from the scope of delivery or purchase extras.
- If heat function fails, ensure it's activated post-program selection by pressing the Heat button—first for low, second for high. Tastensperre (key lock) icon appears if locked; hold the power button to unlock. No sensation? Clean skin, reposition electrodes on all body parts, and adjust intensity separately for channels 1 and 2. Prevent issues by storing in a cool, dry place, avoiding medical implants like pacemakers, and following the manual's operating temperature guidelines.
- For persistent problems, consult the free PDF manual available online. Beurer offers a warranty (typically 3 years); contact support at Beurer's website or local service centers for repairs.
- Preventive measures: Use the timer function to avoid overuse, and test on low intensity first. Reach Beurer support via shop-beurer.com or authorized dealers for personalized help.
Pros and Cons of Beurer EM 59 Heat TENS EMS Device
Pros
- Versatile 70 programs for TENS pain relief, EMS muscle stimulation, and massage, with heat enhancing all therapies—perfect for comprehensive home treatment.
- Two-channel independent intensity control (up to 70 levels) allows treating large areas or both body sides evenly.
- Rechargeable battery and compact design (5.5 x 2.6 x 1.0 inches) make it portable and user-friendly for daily use.
- Drug-free pain management with precise pulses (50–450 µs, 1–150 Hz) and a timer for safe sessions.
- Excellent value for money at $80–$120, outperforming basic TENS units by adding heat and EMS functions.
Cons
- Gel pads wear out quickly with frequent use, requiring replacements—not included beyond the initial 4.
- Learning curve for 70 programs; display shows frequency/pulse width but may overwhelm beginners.
- Not suitable for users with pacemakers or implants, limiting accessibility.
- Compared to premium alternatives like Compex, it lacks app connectivity but excels in affordability and the heat feature.
Overall, the **Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat** offers strong value for versatile electrotherapy.
Customer Reviews: Beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat
Users praise the **Beurer EM 59 Heat** for effective pain relief and muscle recovery, with an average rating of 4.2/5 stars across sites like Galaxus and manual aggregators. "The heat function truly enhances TENS sessions for back pain—game-changer!" notes one reviewer. Common praises include customizable programs and ease of use: "70 options cover everything from workouts to arthritis relief" (5 stars).
Complaints focus on gel pad longevity ("Need extras after a month") and initial setup ("Manual helped, but program navigation takes practice"). Frequently mentioned issues like low battery warnings are resolved via recharging. 67/100 on some manual sites reflects minor usability gripes, but 80% recommend for home TENS EMS therapy. Ideal purchase for chronic pain sufferers seeking a reliable **Beurer TENS EMS heat device**.
Faqs
How do I set up the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat for the first time?
What should I do if the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat won't turn on?
How do I activate and use the heat function on the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat alone?
What programs are available on the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat and how do I select them?
Can the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat be used with a laptop for charging?
How can I optimize performance of the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat for back pain relief?
How do I clean and maintain the beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat?
Why is the heat not getting warm enough on my beurer Digital TENS/EMS Unit with Heat Function EM 59 Heat?
More beurer manuals
- Usage: Beurer Digital TENS/EMS Device with Heat Function EM 89 Heat User Manual
- Setup: Beurer Glass Bathroom Scale GS 225 Instruction Guide
- Setup: Beurer Diagnostic Bathroom Scale BF 990 WIFI User Manual
- Usage: Beurer Glass Bathroom Scale GS 14 User Manual
- Setup: Beurer Diagnostic Bathroom Scale BF 105 Body Complete User Manual
- Usage: Beurer PS 160 Personal Bathroom Scale User Manual
Leave a Comment