The ZBS00 Wireless Switch is a GreenConnect wall-mounted control for switching compatible lighting loads on and off. It can operate as a local switch or join a wireless mesh network for multi-location control with other compatible switches, dimmers, load controllers, receptacles, and sensors.
This 120–277 VAC wall switch is intended for indoor commercial and residential applications where wireless lighting control is needed without adding traveler wiring. A single-gang device box and Decora faceplate are required. The faceplate is installed separately.
Specifications
- Catalog number: ZBS00-D0Z
- Product type: Wireless wall switch and load control device
- Input voltage: 120–277 VAC
- Frequency: 50/60 Hz
- Network: IEEE 802.15.4, 2.4 GHz wireless mesh
- Typical wireless range: Up to 75 feet between devices
- Standby input power: 0.2 W at 120 V and 0.3 W at 277 V
- Maximum device power excluding load current: 0.5 W at 120 V and 0.6 W at 277 V
- LED, CFL, and electronic ballast load: 10 A at 120 V or 277 V
- Magnetic ballast load: 10 A at 120 V or 277 V
- Resistive or tungsten load: 6.67 A at 120 V or 277 V
- Motor load: 1/4 hp at 120 V with 5.8 A FLA, or 1/3 hp at 277 V with 3.0 A FLA
- Operating temperature: 32°F to 104°F (0°C to 40°C)
- Storage temperature: -40°F to 185°F (-40°C to 85°C)
- Ingress rating: IP10
- UL pollution degree: 2
- Impulse voltage: 4000 V
- Installation box: Single-gang device box; multi-gang installations are supported
Detailed Description
The ZBS00 uses a Decora-style rocker paddle for direct ON/OFF operation. Press the top of the paddle to turn the connected load on, and press the bottom to turn it off. A locator LED remains illuminated when the switch is off, helping identify the control in a dark room.
The switch communicates with other GreenConnect devices through a 2.4 GHz mesh network. One compatible load controller, dimmer, or wall switch must act as the network manager when a new GreenConnect network is created. Battery-powered companions, sensors, and receptacles can join a network but cannot create one.
A GreenConnect network can contain a maximum combined total of 16 load controllers, wall stations, receptacles, and sensors. For installations requiring more devices, compatible GreenMAX DRC wireless room controllers can be used as part of the system.
The supported device family includes switching and dimming load controllers, wall dimmers, companion switches, companion dimmers, controlled receptacles, and PIR occupancy/daylight sensors. The ZBS00 itself provides ON/OFF switching rather than load dimming.
Safety
- Switch off power at the circuit breaker or fuse before wiring, and verify that the circuit is de-energized with an appropriate tester.
- Installation must comply with applicable electrical codes and regulations.
- Consult a qualified electrician if any wiring or installation step is unclear.
- Use copper or copper-clad wire only.
- Install the device indoors only.
- Do not leave exposed copper outside the wire connectors.
- Maintain at least 7.9 inches (20 cm) between the device’s radio source and your body during normal operation.
- Do not install the transmitter alongside or directly with another antenna or transmitter.
- Save the installation instructions for future reference.
Setup and Operation
Before Installation
Confirm that the installation location is within wireless network range and that a compatible load is connected. Prepare a single-gang device box, copper or copper-clad conductors, wire connectors, the supplied mounting screws, and a compatible Decora faceplate.
Wiring and Physical Installation
- Turn off the branch-circuit breaker or remove the fuse. Test the wires to confirm that power is off.
- Remove approximately 0.75 inch of insulation from the line and load conductors.
- Remove the precut insulation from the load-controller wires where applicable.
- Connect line, neutral, load, and ground conductors according to the device wiring diagram. Tighten each connection securely and check that no copper is exposed.
- Carefully fold the wires into the wall box and secure the switch with the supplied screws. Avoid sharply bending or pinching the conductors.
- Restore power and test the rocker. The connected load should respond to the ON and OFF commands.
- Verify that the locator LED is illuminated when the load is off.
- If needed, change the switch color before installing the faceplate.
- Install the Decora faceplate.
- Enroll the switch in the GreenConnect network and configure the required operating features.
Creating a GreenConnect Network
- On a compatible load controller, dimmer, or switch, press and hold the top paddle for approximately 5–9 seconds, then release it when the LED indicates the main menu.
- From the main menu, tap the top paddle twice. The device resets as the network manager, and the load toggles OFF-ON twice when the network opens.
- Keep the network open while enrolling additional devices. The network manager’s LED periodically indicates the number of enrolled devices.
- After all devices are enrolled, tap the top paddle on the network manager once to close the network. The connected loads toggle OFF-ON twice to confirm closure.
The network also closes automatically after 10 minutes if no additional device joins.
Joining an Existing Network
- Open the network from a load controller, dimmer, switch, or receptacle that already belongs to the desired network.
- Make sure that no other nearby GreenConnect network is open. Multiple open networks can cause a device to join the wrong system.
- On the ZBS00, enter the main menu and tap the top paddle once.
- The LED blinks green while the switch searches for a network.
- When enrollment succeeds, the connected loads toggle OFF-ON twice with the other network devices.
- Repeat the process for each additional device.
If no network is found within approximately two minutes, the LED stops blinking and the switch exits the menu. To join a GreenMAX DRC wireless network, place the switch in network-search mode and follow the room controller’s enrollment procedure.
LED Diagnostic Indicators
- Red, three blinks: Device is not connected.
- Green, three blinks: Active connection.
- Green, two blinks: Incomplete connection.
- Green, one blink: Inactive connection.
- Yellow, one blink: Main menu or menu exit confirmation, depending on the action.
- Yellow, two blinks: Reset confirmation.
- Red blinking: Network-manager activity or network reset status.
Entering the Main Menu
Press and hold the top paddle for about four seconds to view the device diagnostic indication. Continue holding for approximately seven seconds more until the LED blinks yellow once, then release. The LED blinks yellow rapidly while the switch is at the main menu.
Press and hold the top paddle for approximately seven seconds to return from a feature menu to the main menu. Press and hold again for approximately seven seconds to leave the main menu.
Feature Settings
Features 3 through 9 are stored in the network manager. To access one, enter the network manager’s main menu and tap the top paddle the number of times matching the feature number. The LED reports the selected feature and its current setting. Tap the paddle the required number of times to choose a new value.
- Feature 3, occupancy auto-ON level: 100%, 50%, 25%, manual-ON vacancy mode, or restore last level. Restore last level is the default.
- Feature 4, occupancy sensitivity: Medium, Low, or High. High is the default.
- Feature 5, vacancy time-out: Test mode, 30 minutes, 20 minutes, 10 minutes, 5 minutes, or disabled. The default is 20 minutes.
- Feature 6, partial-OFF level: Disabled, 50%, or 25%. Disabled is the default.
- Feature 7, partial-OFF time-out: 30 minutes, 20 minutes, 10 minutes, or 5 minutes. The default is 20 minutes.
- Feature 8, daylighting target: Disabled, 25 footcandles, 35 footcandles, or 45 footcandles. Disabled is the default.
- Feature 9, vacancy level: 0%, 50%, or 25%. The default is 0%.
The test-mode vacancy setting operates for 60 seconds during a five-minute test period and then returns to the previous setting. Allow up to three minutes of inactivity for the feature menu to close automatically. When changing occupancy sensitivity, ensure the sensor is not in power-save mode.
Local and Network Control
Feature 10 determines whether the switch controls only its local load or participates in network control. The default setting is Local.
- Enter the switch’s main menu.
- Tap the top paddle ten times to open feature menu 10.
- Tap the paddle once to select Network control.
- Use the LED blink pattern to confirm the new setting.
With Network control enabled, the switch controls its local lighting load and the other loads assigned to the network. Return to the main menu or wait for the feature menu to exit automatically after approximately three minutes of inactivity.
Resetting the Switch
To restore default settings and remove the switch from its network, press and hold the top paddle for approximately 12 seconds. Release it after the LED blinks yellow twice. The LED then blinks red while the switch leaves the network and resets.
If the ZBS00 was the network manager, resetting it breaks that network and disconnects the devices enrolled in it.
Troubleshooting
The Load Does Not Turn On or the Status LED Is Off
- Check whether the circuit breaker has tripped or been switched off.
- Verify that the switch is receiving the required line voltage.
- Recheck the line, neutral, load, and ground connections against the wiring diagram.
- Confirm that the switched-output wiring is connected correctly.
- Inspect wire connectors for loose conductors.
Lights Flicker or Do Not Respond as Expected
- Confirm that the connected load type is suitable for the switch and within its specified limits.
- Check the lamp or fixture connection.
- Inspect all wire connectors and tighten any loose connections.
- For an installation that includes a compatible dimming controller, verify that the control wiring is correct and that the load meets the controller’s minimum and maximum requirements.
The Device Will Not Enroll
- Confirm that the intended network is open.
- Close other nearby networks so the switch cannot join the wrong system.
- Move the device within the wireless range of the network.
- Check whether the network has reached its maximum of 16 devices.
- Reset the switch and repeat the enrollment process if the device remains associated with an unwanted network.
Warranty
The ZBS00 is covered by a limited five-year product warranty. Warranty coverage is subject to the manufacturer’s stated terms and conditions.
Pros & Cons
- Pros: Supports 120–277 VAC installations, provides wireless mesh networking, offers local or network control, fits a single-gang box, supports multi-gang installations, and includes a useful locator LED.
- Pros: Handles LED, CFL, ballast, resistive, tungsten, and specified motor loads within its ratings.
- Cons: Requires line-voltage wiring and professional care during installation.
- Cons: A compatible network manager is required to create a GreenConnect network, and the system is limited to 16 enrolled devices unless expanded through a compatible room controller.
- Cons: A Decora faceplate is required and must be installed separately.
Faqs
How do I safely install the ZBS00 Wireless Switch?
What voltage and load types can the ZBS00 control?
How do I create a GreenConnect wireless network with the ZBS00?
How do I enroll the ZBS00 in an existing wireless network?
What do the ZBS00 paddle and locator LED controls do?
Why will the ZBS00 not enroll in the GreenConnect network?
How can I reset the ZBS00 Wireless Switch to factory settings?
What should I do if the ZBS00 load does not turn on?
More leviton manuals
- Installation: Leviton AGTR1 AGTR2 AFCI GFCI Receptacle Instruction Manual
- Installation: Leviton R, P, B, and M Series Surge Protective Devices Instruction Manual
- Installation: Leviton GreenConnect Wireless Load Controller ZKS00 Instruction Manual
- Leviton Electronic Countdown Timer Switch LBT60 | Operating Instructions
- Leviton Decora Smart Dimmer Switch D36HD-1RW User Manual
- Leviton Tamper-Resistant Outlet 2nd Gen D215R User Guide | Install & Connect
Leave a Comment