Mosfiata Cool & Warm Mist Humidifier JS502 User Guide

cover-image

Content

Mosfiata Cool & Warm Mist Humidifier JS502 Introduction

It has the ability to produce warm or cool mist, this humidifier is suitable for year-round use. With a big capacity tank that can run continuously for up to 36 hours on a single fill, it's perfect for medium-sized to large rooms. In addition, the JS502 has an easy-to-use touch control panel, a convenient remote control, and an integrated humidistat that automatically maintains the ideal humidity level. It also has an essential oil tray and a timer feature, which enable aromatherapy benefits. It is estimated to be priced at $48.

Parts and installation drawing 

parts_mosfiata_cool_&_warm_humidifier_js502.png

Specifications 

  • Product name: Cool & Warm Mist Humidifier
  • Model: JS502
  • Voltage: 110V
  • Frequency: SOHz
  • Power: 116W

Control panel instruction of JS502

control_panel_intructions_mosfiata_cool_&_warm_humidifier_js502.png
  1. 0N/OFF: Plug the power cord into a compatible mains power supply,press ON/OFF button to switch on the humidifier,LED display and night light will illuminate and the humidifier will work on minimum mist,press again to stop working.Press the ON/OFF button for 3 seconds to turn off the screen ,press any button will active. 
  2. MIST SETTING:Press to set the mist gear:low-middle-high.
  3. ANION : Press once to start the anion,press the AN ION button for 3 seconds to switch the function.
  4. 360° ROTATION: Press once to start the 360° rotation sp ay nozzle.
  5. TIMER: Press to set 1~8 hours and turn off,the LED display will reflect your selection.
  6. HEATING: Press once to start the heating.

Description

High-performance equipment like the Mosfiata Cool & Warm Mist Humidifier JS502 maintains ideal humidity levels and fosters a cozy and healthy living or working environment. Its cool mist mode, which offers a cool, refreshing mist to relieve dry skin and sinus issues, is ideal for the summer. Conversely, its warm mist mode is perfect for the winter because it offers a calming, cozy warmth that eases coughing and congestion. Additionally, the humidifier has an easy-to-use built-in LED display that indicates the mist mode and current humidity level.

Using your humidifier 

  • STEP 1: Place the humidifier on the horizontal floor,remove the cover and add distilled water to the tank.(see picture 1) 
  • STEP 2: Plug the power cord into a compatible mains power supply. 
  • STEP 3: Press ON/OFF button,the humidifier will start working,press the MIST button to adjust the mist volume,the spray nozzle can 360 ° automatic rotating. 
  • STEP 4: If the water level is too low,the alarm will sound three times,"Water shortage" indicator light will flash 10 seconds then the humidifier will turn off;please must unplug the power cord before fill in the water tank. 
  • STEP 5: Add essential oil: Pour proper essential oil into the box.(Note: can not pour into the water basin , otherwise it will affect the mist effect and damage the water basin parts)(see picture 2) 

    using_your_humidifier_mosfiata_cool_&_warm_humidifier_js502.png

Warm warning 

  • About usage: 
    Please take the water cover off from the water tank or take out whole water tank to add water,put back again after adding water for normal use. 
  • About the water on the base: 
    The humidifier uses ultrasonic mist board to disperse liquid water into mist. The water tank is just a water storage tool.,water accumulate in the water basin is normal phenomenon. 
  • About adjustment of misting: 
    If the humidifier body and the floor get wet,it mean the room with high humidity,please adjust the misting properly.

Setup Guide

Setting up the Mosfiata Cool & Warm Mist Humidifier JS502 is a breeze. 

  • Simply fill the tank with clean water, plug in the appliance, and select your desired mist mode. The humidifier will automatically start working to reach your desired humidity level. 
  • It is recommended to clean the humidifier once a week to ensure optimal performance and hygiene. 
  • To clean, simply empty the tank, rinse with clean water, and wipe the appliance with a damp cloth. 

Clean and care 

  1. Make sure the humidifier is completely unplugged from any power source before cleaning.
  2. Take the water cover off to clean the water tank first, wipe off the scale in the water tank with a soft cloth, and then rinse with clean water.
  3. If there is scale on the surface of the water tank or ultrasonic mist part, pour in the dissolved scale remover, citric acid or white vinegar, and then wipe the body with a cotton swab or brush and rinse with clean water.
  4. Rinse the soft cloth in warm water less than 40 degrees Celsius, wipe off the surface stains, must not use wire ball, nylon cloth wipe the body, so as to avoid the surface scratch damage.
  5. Do not use thinner, toluene, acidic detergent, lamp oil, alcohol or chemical cloth to wipe.
  6. Clean the entire part of the machine base, including the power cord. Wipe it with a clean cloth,do not wash the base with water,do not put the base into the water.
  7. The strainer under the base should be cleaned with water every two months,then let it to dry. 
  8. When not in use for a long time,clean and allow it to dry completely,pack it back in the original box according to the original packing order,and store it in a dry place.

WARNINGS 

Read this manual carefully and keep it for future reference.
Please strictly follow the following instructions. Disregard of these instructions or operational errors may cause serious accidents or other injuries, so please follow the following instructions:

  1. Rated voltage is AC110V~50Hz, please check your voltage whether suitable.
  2. Do not damage, modify, force-bending, pull, squeeze or tip-up the power cord.,do not press or put heavy objects on the power cord, otherwise it will damage the power cord and cause danger .
  3. Always unplug the unit when not in use or before washing.
  4. Please confirm the unit connected with the socket successfully,do not use lengthened power cord.
  5. Please hold the plug part when unplugging, do not pull the power cord by force.
  6. When the product is working, be sure to keep a certain distance between the unit and socket also with other electric appliance, keep the plug out of reach, and keep away from inflammable and explosive objects.
  7. Please use on the smooth ground to avoid the product tilt, fall, cause the humidifier water overflow or damage.
  8. Please do not use a hard appliance to touch the ultrasonic mist part,only use cotton or hairbrush to clean.
  9. Do not use chemical solvent,gasoline, kerosene, polishing powder to clean the humidifier.
  10. Do not use this humidifier around the bathtub, shower head or swimming pool to avoid electric shock or fire.
  11. To protect against the risk of electric shock,do not immerse power cord or plug in water or any other liquid
  12. Please unplug the power cord before using, cleaning or moving the humidifier for a long time.
  13. Do not let children use this product alone, please place it out of reach of children.
  14. Please unplug when filling into water and cleaning, please do not turn on the mist function when waterless.
  15. Do not use wet hands to plug in and out of the power supply. Do not contact the power cord and plug during thunder, so as to avoid electric shock.
  16. If the product is damaged or cannot operate normally, please turn off the power immediately and pull out the plug. Do not disassemble or assemble it at will
  17. This product is for use only at home or in similar places.
  18. If the power cord is damaged, it must be replaced by the manufacturer or its maintenance department or similar full-time personnel to avoid danger 

Environmental protection instructions
The unit meet the demand of {Management methods for restricted use of hazardous substances in electrical and electronic products)) . In the environmental protection use period, consumers will not appear in the normal use of harmful substances leakage, precipitation and other problems affecting consumer health, you can rest assured to use.
The life-span of environmental protection is 10 years. The “environmental protection service life” shall only be valid when the products are used under normal circumstances as described in this manual.

environmetal_instructions_mosfiata_cool_&_warm_humidifier_js502.png

Troubleshooting

Regular Problems Analysis 
The cause of the problem and treatment method 

Not NormalReasonSolution
Display no illuminate, no mistCheck the plugConnect the power
Display illuminate, no mist no windOnly connect the powerTurn-on the unit
Power on, no mist no windIlluminate red, water tank has not enough waterAdd more water; check the float on the bottom of the tank whether flexible; reset the ring and spring in the water tank
Whether turn-on the constant humidity modeThe unit stops working when on constant humidity mode after meeting enough humidity. After stopping the constant humidity mode, the unit will continue humidifying-
Mist smallUltrasonic mist part film scale, water dirty or storage time is too longClean the ultrasonic mist part, using clean water

Remark:according to the above operation,the unit still can not work,please contact our after-sales customer service or dealers. 

Mosfiata Cool & Warm Mist Humidifier JS502 Pros & Cons

  • Pros
    • Dual mist modes for year-round use
    • Large tank capacity and long run time
    • Precise humidity control and 360-degree mist distribution
    • Low noise level and built-in LED display
  • Cons
    • May require frequent cleaning
    • Only covers up to 40 square meters

Customer Reviews

Customers have praised the Mosfiata Cool & Warm Mist Humidifier JS502 for its efficient and reliable performance, as well as its sleek and modern design. Many have noted that the appliance is easy to use and maintain, and that it has helped to improve the air quality in their living or working space. Some common complaints include the need for frequent cleaning and the limited coverage area.

Faqs

In the event that I observe a drop in mist output, what should I do?

Make sure the water tank is not empty, check for obstructions in the nozzle, and determine whether the water filter needs to be replaced. To maintain optimum performance, clean the ultrasonic disk on a regular basis according to the manufacturer's instructions.

How can I keep bacteria and mold from growing inside the humidifier?

Mosfiata Cool & Warm Mist Humidifier JS502 important to clean regularly. In order to lessen mineral deposits, use demineralized or distilled water, empty the water tank once a day, and avoid leaving water in the tank for long periods of time. Additionally, use a water-white vinegar or hydrogen peroxide solution to cleanse the tank and other components once a week.

Is it possible to modify the Mosfiata Cool & Warm Mist Humidifier JS502, and if so, how?

The integrated humidistat is adjustable, yes. You may program the gadget to switch on and off automatically based on the humidity level you specify. Without requiring manual modification, this feature aids in maintaining a comfortable humidity level in your space.

How energy-efficient is the Mosfiata Cool & Warm Mist Humidifier?

Energy efficiency is a design feature. Compared to steam vaporizers, the humidifier uses ultrasonic technology, which requires less electricity. Additionally, by shutting off the humidifier when not in use, the auto-shutoff feature contributes to energy conservation.

What kind of screen does the Mosfiata Cool & Warm Mist Humidifier JS502 have, and what data does it display?

The JS502 has an LED display that indicates the temperature, humidity level, timing settings, and mist mode at any given moment. This makes monitoring and setting adjustments simple.

If I need to move the Mosfiata Cool & Warm Mist Humidifier to a different area, how do I carry it?

To avoid spills, always empty the water tank before moving the humidifier. To prevent damage, carry the tank and the base apart. Make sure you unplug the humidifier from the power source and turn it off.

Does the JS502 generate any toxic byproducts?

It is not true that the humidifier emits any hazardous byproducts. Unlike steam vaporizers, which can cause burn hazards, ultrasonic humidifiers do not heat water to boiling degrees, making them safe for use in homes.

What is the warranty period for the humidifier?

The warranty period for the Mosfiata Cool & Warm Mist Humidifier JS502 is 12 months.

What kind of materials goes into making the JS502? Are they robust and safe?

Usually constructed from premium, BPA-free plastic, the Mosfiata JS502 offers durability and safety. The materials' resistance to deterioration from water and essential oils is part of their design.

If the LED display malfunctions or displays inaccurate readings, what should I do?

Verify the power supply and make sure the Mosfiata Cool & Warm Mist Humidifier JS502 is correctly plugged in. Should the display still not work properly.

Underwater Viewing System VS485C

IR850 Supernova INFRA-RED ILLUMINATOR

Leave a Comment

Name

Email

Comment