Setup: Quatro CollectALL MedEVAC MultiPure PowerStation PS2 Owner Manual

Content

Overview

The CollectALL MedEVAC MultiPure PowerStation PS2 is a multi-stage dust and fume extraction unit designed to capture larger particles, fine dust, and model-dependent odors before air is returned through a high-performance blower system. It is suited to workstation and milling applications where steady suction, remote start capability, and sealed filtration are important.

This guide is based on the product’s operations and maintenance information and focuses on setup, safe use, control functions, and routine service tasks for the CollectALL MedEVAC MultiPure PowerStation PS2.

Specifications

  • Model: CollectALL MedEVAC MultiPure PowerStation PS2
  • Nominal airflow: 220
  • Power: 120 V, single phase, 60 Hz
  • Current: 15 amps
  • Approximate dimensions: 26 in. H x 13 in. W x 16 in. D
  • Approximate weight: 80 lb
  • Air inlet and hose connection setup: 3 in. hose on the CollectALL version, 18 ft hose on the MedEVAC MultiPure version, and 6 ft hose on the PowerStation version
  • Control features: power button, speed up/down controls, remote socket, and LED status indicators

Detailed description

The CollectALL MedEVAC MultiPure PowerStation PS2 uses a layered filtration path to reduce contamination at the source. Filter bags handle the heavier debris first, the HEPA filter captures finer dust, and an odor filter is used on models or applications that require odor control. A heavy-duty blower section then maintains airflow through the hose and filtration stack.

The unit includes a front filter access door, internal filter bags, a HEPA filter, and a blower/motor section with electronic status monitoring. Depending on the version, the shipped accessories vary. The CollectALL version includes a power cord, air inlet plate, clamps, and remote hand-switch with a 12 ft long, 3 in. diameter hose. The MedEVAC MultiPure version includes a power cord, air inlet plate, remote hand-switch, rubber hose cuffs for accessory sizing, and an 18 ft hose. The PowerStation version includes a power cord, air inlet plate, milling auto-start cable, and a 6 ft hose.

The control panel supports manual operation, remote start, and variable speed adjustment in nine steps. LED indicators show when the system is on, waiting for a remote signal, or requiring service for filters or motors.

Safety

Before using the unit, read and keep the instructions so the filter system is installed and serviced correctly. The filter must always be in place during operation, and no substitute filter should be used because it changes the unit’s designed performance.

Use only a properly grounded 120 V electrical circuit and never bypass the grounded plug with a two-wire adapter. Unplug the power cord before any service work. If the motor area has been running, avoid touching the motor housing immediately after shutdown because it can remain hot.

All fasteners should stay tight, and the special filter assembly should be handled only after the user understands how it is removed and replaced. The manual also warns that a missing filter can damage the motor quickly.

For dust collection setups using plastic tubing, static grounding is important. The grounding method described uses bare copper wire bonded through the ducting and connected to grounded metal points so static charge can safely dissipate.

Setup and operation

Install the unit by opening the filter door, removing the protective plastic from the HEPA filter and odor filter if one is installed, and confirming that the filter bags are correctly seated in the two tubes below the top of the filter section. If the caster option was purchased, install the wheels before moving the unit into place.

Connect the power cord to a grounded 120 V wall outlet, then attach the unit to the proper workstation or milling machine. The dirty-air inlet collars are installed on the back side of the unit.

To start the system, press the red power button on the control panel. The System ON light should illuminate to show that the unit is operating. Press the power button again to stop the unit.

Remote operation is supported through the remote socket on the control panel. A remote hand-switch or foot pedal can be connected for hands-free start and stop control. The Remote/Standby indicator shows the operating state: a flashing light means standby, a solid light means the unit is operating, and an off light means the unit is not running.

The speed controls adjust airflow in nine increments. This lets the user match suction to the task and balance airflow across workstations.

The temporary mode feature allows manual control while the unit is in standby. Pressing the power button starts the motor directly, and pressing it again stops the motor even if a remote signal is present. Disconnecting the power cord disables remote sensing.

Cleaning and maintenance

Routine maintenance centers on filtration, motor condition, and seal integrity. Filter replacement is required when the service filter indicator activates or when suction drops, dust appears in the motor section, or the HEPA gasket shows wear.

The unit uses a sealed filter stack, so maintaining the gaskets matters as much as replacing the filters themselves. During annual inspection, verify that all gaskets are in good condition, check that rubber grommets remain tight, and confirm that the acoustic insulation inside the fan section is firmly attached.

If a filter door gasket sticks slightly, a light application of transparent grease or petroleum jelly can help. When moving the unit, confirm that the rubber grommets remain secure after repositioning.

Troubleshooting

If the unit will not start, first check the power source and breaker, then consider motor wear or brush wear if electrical supply is good. A tripped breaker on the panel may also need to be reset.

If airflow is weak, inspect the hose path for blockage and replace a clogged filter. Uneven suction between workstations is often caused by different hose lengths and can be corrected by adjusting the damper or blast gate at each station.

If the motor shuts off, the issue may be high input current, consumed graphite rods, or a burnt motor. Make sure the filter is installed and the circuit breaker is reset before replacing parts.

If airflow is too strong, check whether the filter is missing. Excessive noise can point to the turbine impeller contacting the housing, which typically calls for motor replacement.

Warranty

QUATRO provides a one-year warranty from the shipment date against defects in material and workmanship under normal use and service. The warranty is limited to replacement of defective parts only.

The warranty excludes misuse, abuse, neglect, improper assembly, vandalism, acts of God, normal wear, unauthorized modifications, installation of non-recommended parts, and operation outside the specified voltage range.

Pros & Cons

  • Pros: Multi-stage filtration captures heavy debris, fine dust, and odors in a single system.
  • Pros: Remote hand-switch and foot-pedal support make workstation use flexible.
  • Pros: LED diagnostics help identify filter and motor service needs early.
  • Pros: Variable speed control allows better suction matching for different tasks.
  • Cons: The unit depends on correct filter installation and proper grounding to operate safely.
  • Cons: Filter and motor service are essential, especially in high-use environments.

PDF

Faqs

How do I install the CollectALL MedEVAC MultiPure PowerStation PS2 before first use?

Open the filter door and remove all protective plastic from the HEPA filter and odor filter, if your model uses one. Make sure the filter bags are correctly fitted into the two tubes beneath the top of the filter section, and confirm any optional casters are installed securely before moving the unit. Then connect the power cord to a grounded 120-volt outlet and attach the unit to the workstation or milling machine you plan to use.

What do the startup lights on the PS2 control panel mean?

Press the red POWER button to start the unit and check that the System ON light turns on, which confirms the extractor is operating. Pressing POWER again shuts it off. If you connect a remote hand-switch or foot pedal, the Remote/Standby light shows whether the unit is waiting for a signal, running remotely, or in a temporary standby state. These lights are the quickest way to confirm whether the dust collection system is ready.

Why will the PowerStation PS2 not start even when it is plugged in?

If the unit does not start, first verify the outlet is grounded and supplies the correct 120-volt, single-phase power. Check the breaker, confirm the filter is installed, and make sure the access doors are fully closed. The manual also lists a faulty power supply, worn brushes, or a burned motor as possible causes. If airflow components are blocked or the circuit is overloaded, the unit may also shut down for protection.

How do I know when the PS2 filters need replacement?

The control panel will alert you when filter service is due, usually with a light and periodic beeps. You may also notice weaker suction, dust escaping past the filter stage, or dust collecting in the motor section even when the filter appears seated. Those signs can mean the filter is clogged or punctured, or that the HEPA gasket is worn. The unit should never run without all filters properly installed.

How do I reset the filter service alert after replacing filters?

After replacing the filters, close the motor access door and reconnect power. Start the unit, then press and hold the SPEED UP and SPEED DOWN buttons together until the unit beeps continuously. From there, use SPEED DOWN until the Service Filters light flashes, then press and hold POWER until the beeping stops. Once the light turns off, the reset is complete and the unit is ready for normal operation.

What should I do if suction is weak on the CollectALL MedEVAC MultiPure PowerStation PS2?

Weak suction usually points to a clogged filter or a blockage in the hose or connected workstation line. Check the full airflow path for bends, debris, or crushed tubing, then inspect the filter stack for dust loading or improper seating. The manual also notes that suction can vary from station to station when hose lengths differ, so adjusting dampers or blast gates can help balance performance across multiple work areas.

What safety checks should I follow before operating the PS2?

Make sure every filter is installed before switching the unit on, because running without a filter can damage the motor. Keep the unit on a grounded electrical circuit and never use a two-wire adapter to defeat the ground. Before servicing, unplug the power cord and allow the motor to cool if needed, since the exterior can be hot. Also confirm all fasteners, grommets, and access doors are secure.

How do I interpret the motor and airflow alerts on the PS2?

Motor alerts usually mean the brushes are nearing the end of service life or the motor needs replacement. A solid motor warning light indicates service is due, while a pressure or airflow alarm can point to blocked filters, open doors, or a missing filter. If the unit beeps continuously and shuts down, check for obstructions, verify filter installation, and allow the motors to cool before restarting. Addressing the cause quickly helps prevent damage.