Rh-Peterson DVI-25m Series Direct-Vent Gas Heating Fireplace User Manual

Content

RH-Peterson DVI-25m Series Direct-Vent Gas Heating Fireplace Manual

Introduction to the RH-Peterson DVI-25m Direct-Vent Gas Fireplace

The RH-Peterson DVI-25m Series Direct-Vent Gas Heating Fireplace is a compact direct-vent insert designed to add gas-fired warmth and a realistic fire appearance to a suitable existing fireplace opening. The 25-inch mSeries model combines a sealed combustion design with a millivolt control system, making it suitable for installations where dependable, wall-switch-style operation is preferred.

This direct-vent gas fireplace uses outside air for combustion and vents combustion products outdoors through an approved vent system. Because the firebox is sealed from the room, the appliance can provide supplemental heat while helping preserve indoor air quality when correctly installed and maintained. The design also supports flexible installation in compatible masonry or factory-built fireplace applications.

The DVI-25m is intended for homeowners, remodeling professionals, and qualified fireplace installers who want to convert an unused fireplace into a controllable gas heating appliance. Typical applications include living rooms, family rooms, bedrooms where permitted by local codes, and renovation projects that require a cleaner alternative to wood burning.

Available configurations may vary by fuel type, valve package, log set, and installation components. Always confirm the complete model designation on the rating plate before purchasing parts or beginning work. Installation, gas connection, venting, and safety testing must be performed according to the appliance manual and applicable local codes by qualified personnel.

RH-Peterson DVI-25m Specifications and Key Features

  • Appliance type: Direct-vent gas fireplace insert.
  • Series: 25-inch mSeries.
  • Control system: Millivolt gas valve system, with control options determined by the exact configuration.
  • Fuel options: Natural gas or propane versions may be available; use only the fuel identified on the rating plate.
  • Input range: Published product information lists approximately 17,000 to 25,000 BTU per hour for natural gas and 17,000 to 20,000 BTU per hour for propane.
  • Ventilation: Sealed direct-vent system using approved intake and exhaust components.
  • Combustion: Outdoor combustion air is drawn through the vent system rather than from the room.
  • Fireplace opening: Required dimensions depend on the exact insert configuration, vent arrangement, and surrounding construction.
  • Controls: The millivolt system can typically operate without household electrical power, although optional accessories may have separate requirements.
  • Viewing area: A glass-front firebox with a decorative log and ember arrangement selected for the model.
  • Clearances: Mantel, trim, side, top, and combustible-material clearances must be verified from the exact installation manual.

Detailed Description: How the DVI-25m Direct-Vent Fireplace Works

The DVI-25m operates inside a sealed firebox behind a listed glass barrier. When the control system calls for heat, the pilot and main burner ignite the approved fuel mixture. The burner flame heats the firebox and decorative log set, while the direct-vent assembly routes exhaust outdoors and supplies combustion air from outside.

The insert is designed for installation into a compatible existing fireplace opening. A qualified installer evaluates the opening, chimney or vent path, clearances, gas supply, and hearth construction before positioning the unit. The outer frame conceals the installation gap and provides a finished appearance around the viewing area.

Daily operation generally involves turning the burner on or off and adjusting the flame or heat level when the installed control package permits it. Allow the glass and surrounding surfaces to cool completely before cleaning. Remove dust from accessible trim with a soft, dry cloth, and clean the glass only with a manufacturer-approved fireplace-glass cleaner. Do not use abrasive pads, household glass cleaner, or wet cleaning products on hot glass.

Inspect the flame appearance, pilot area, vent termination, and log placement periodically. Keep the burner ports clear and never rearrange logs, embers, or decorative media while the appliance is operating.

Setup Guide for the RH-Peterson DVI-25m Series

  1. Verify the model: Read the rating plate and confirm the fuel type, model suffix, input rating, and approved accessories.
  2. Inspect the installation site: Confirm that the existing fireplace opening, hearth, mantel, sidewalls, and combustible materials meet the required dimensions.
  3. Plan the vent route: Use only approved direct-vent components and follow the permitted termination and clearance arrangement for the exact model.
  4. Prepare the gas supply: Have a qualified gas technician install the shutoff valve, connector, and regulator arrangement required by local code.
  5. Install the insert: Position and secure the appliance without crushing the vent system or obstructing service access.
  6. Install the log set: Place each log and ember exactly as shown in the model-specific instructions. Incorrect placement can affect flame appearance and combustion.
  7. Connect controls: Install the approved wall switch, remote, or other compatible millivolt accessory if supplied with the configuration.
  8. Test operation: Check for gas leaks, ignite the pilot, operate the burner, and verify stable flames and proper venting.
  9. Complete safety checks: Confirm that the glass is secured, the vent termination is unobstructed, and all clearances are maintained.

Never modify the vent system, bypass safety controls, operate the fireplace with damaged glass, or connect accessories that are not approved for the appliance.

Troubleshooting the DVI-25m Direct-Vent Gas Fireplace

Pilot will not light

Confirm that the gas supply is open, the control knob is in the correct position, and the pilot lighting procedure is being followed. If the pilot remains difficult to light, stop and contact a qualified service technician. Do not hold the control open longer than instructed.

Pilot lights but goes out

Allow the thermocouple or thermopile to heat according to the operating instructions before releasing the control. Check for drafts, blocked intake or exhaust terminals, incorrect pilot flame contact, or a fuel-supply problem. A technician should test the safety circuit and gas pressure.

Main burner does not ignite

Check that the wall switch or remote has working batteries where applicable and that the control wiring is secure. A weak thermopile, defective switch, damaged valve, or interruption in the gas supply requires professional diagnosis.

Uneven flames or soot

Turn the appliance off and let it cool. Inspect for incorrectly positioned logs, blocked burner ports, inadequate venting, or a contaminated glass panel. Soot, yellow staining, or unusual flame behavior should be evaluated before continued operation.

Maintenance and support

Schedule inspection and cleaning according to local requirements and the owner’s manual. Keep the model and serial information available when contacting RH Peterson or an authorized fireplace service provider. Warranty coverage and service procedures depend on the original documentation, installation quality, and use of approved parts.

Pros and Cons of the RH-Peterson DVI-25m

Advantages

  • Direct-vent efficiency: Uses a sealed combustion system rather than relying on room air for combustion.
  • Supplemental heat: The published input range provides useful zone heating for appropriately sized rooms.
  • Millivolt operation: The basic control system can remain functional during a household power interruption when installed as designed.
  • Remodeling flexibility: The insert format is intended for conversion of a compatible existing fireplace.
  • Low daily effort: Compared with wood burning, operation avoids firewood storage, ash removal, and chimney soot associated with solid-fuel fires.
  • Realistic presentation: A decorative log and ember arrangement creates a traditional fireplace appearance.

Limitations

  • Professional installation required: Venting, gas connections, clearances, and commissioning should not be treated as do-it-yourself tasks.
  • Opening restrictions: The existing fireplace must meet the exact dimensional and structural requirements for the selected configuration.
  • Fuel-specific parts: Natural gas and propane versions are not interchangeable without approved conversion procedures.
  • Routine inspection remains necessary: Direct venting reduces maintenance compared with wood burning but does not eliminate service needs.
  • Best suited for: Homeowners seeking supplemental heat and gas-fire convenience.
  • Consider another solution if: The installation site cannot meet venting, clearance, gas-supply, or local-code requirements.

Important Safety Information

Read the complete owner’s and installation instructions before operating the RH-Peterson DVI-25m Series Direct-Vent Gas Heating Fireplace. Keep combustible materials, furnishings, decorations, and children away from hot surfaces. Do not operate the appliance if the glass is cracked or missing, the vent is obstructed, or a gas odor is present. If gas is smelled, avoid switches and open flames, leave the building, and contact the gas supplier or emergency services from a safe location.

Use only replacement parts, log sets, valves, controls, and vent components approved for the exact model. Local building, fuel-gas, and fireplace codes take precedence over general guidance.

PDF

Faqs

How do I set up the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace for the first time?

Have the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace installed by a qualified gas-fireplace professional. The installer must confirm the correct fuel type, approved direct-vent components, framing dimensions, clearances, gas connection, and termination location using the exact model manual. The vent must discharge outdoors and should not be connected to a chimney or improvised duct. Before first use, check that the glass, logs, burner, access panels, and safety controls are correctly installed.

What fuel and gas supply requirements apply to the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace?

Use only the fuel type identified on the fireplace rating plate and conversion documentation. The DVI-25M series may be configured for natural gas or propane, but the burner orifices, regulator, and supply pressure must match the approved configuration. Never convert the fireplace yourself or connect it to an unregulated supply. A qualified technician should install the shutoff valve, test every gas joint for leaks, and verify operating pressure before the fireplace is placed into regular service.

Why does my rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace fail to ignite?

First, confirm that the gas supply is on and that the control switch, thermostat, or remote is calling for heat. Check whether the pilot lights and remains lit; do not repeatedly operate the ignition if you smell gas. Make sure the glass assembly and access panels are properly seated, because safety interlocks may prevent operation. If ignition fails repeatedly, the pilot goes out, or gas odor is present, turn the appliance off and contact a qualified service technician.

What should I check if the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace shuts off after starting?

A fireplace that starts and then shuts down may have a weak pilot flame, restricted venting, incorrect gas pressure, a dirty flame sensor, or a control-system fault. Turn the unit off and allow it to cool before checking for visible blockage around the exterior termination. Do not alter the vent, bypass safety devices, or adjust the regulator. Persistent shutdowns require professional testing of the pilot assembly, vent system, gas pressure, and safety sensors.

How can I improve heat performance from the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace?

Keep furniture, curtains, decorative objects, and combustible materials outside the clearances specified for the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace. Make sure the exterior vent termination is unobstructed by leaves, snow, nests, or construction materials. Operate the fireplace with the approved glass and vent configuration installed; removing components can reduce safety and performance. If heat output seems unusually low, have a technician verify fuel pressure, burner condition, venting, and thermostat operation.

Can I install a custom log set, glass panel, or vent pipe on the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace?

Use only logs, glass components, burner parts, and direct-vent materials approved for the exact DVI-25M model and fuel configuration. Decorative substitutions can change flame behavior, block burner ports, damage the glass, or interfere with combustion and venting. Do not mix vent components from unrelated manufacturers unless the installation manual specifically permits them. Before replacing any part, compare its model and certification information with the rating plate and approved parts list.

How should I clean and maintain the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace?

Turn off the gas, disconnect power if applicable, and let the fireplace cool completely before maintenance. Clean the glass only with a product approved for gas-fireplace glass, using a soft cloth and avoiding abrasive materials. Keep the burner, pilot area, air openings, and logs free of dust and debris without rearranging components unless the manual instructs you to do so. Schedule professional inspection of the vent, gas connections, burner, pilot, and safety controls at regular intervals.

What should I do if the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace produces soot, unusual odors, or condensation?

Turn off the rh-peterson DVI-25m Series Direct-Vent Gas Heating Fireplace if you notice soot, delayed ignition, persistent unusual odor, or abnormal condensation. A small odor during an initial burn may come from curing materials, but continuing odor or black deposits can indicate combustion, venting, log-placement, or gas-pressure problems. Do not use the fireplace until a qualified technician inspects it. Never cover the vent termination or attempt to correct flame appearance by modifying burner orifices.

More rh-peterson manuals

Leave a Comment