Introduction

The rh-peterson G46 Real Fyre Vented Gas Log Sets are designed to create a realistic wood-burning appearance with the convenience of gas operation. The G46 burner system is intended for use with approved vented gas logs and an open, properly vented fireplace. Its angled burner layout helps conceal the gas valve while providing space for a fuller flame presentation.

Available in multiple sizes and fuel configurations, the G46 system can support natural gas or liquid propane, depending on the exact model and installation kit. Options may include standing-pilot, intermittent-pilot, and manual or variable-flame controls. The burner is ANSI certified and is compatible with many Real Fyre log styles when the selected logs and burner are approved for use together.

This vented gas log set is suited to homeowners replacing traditional wood fires, remodeling an existing fireplace, or adding realistic decorative flames to a living room, den, family room, or other approved indoor fireplace. It is not a sealed heating appliance and should not be installed in a fireplace that lacks a suitable chimney or approved vent path.

Before installation, confirm the fireplace dimensions, fuel type, log-set compatibility, gas supply, and local code requirements. Professional installation is strongly recommended for gas connections, pilot systems, burner placement, and final safety testing.

Specifications and Technical Details

  • Product type: Vented gas log burner system for approved Real Fyre gas logs.
  • Fuel options: Natural gas or liquid propane, according to the selected model and configuration.
  • Available burner sizes: G46-18/20, G46-24, and G46-30.
  • G46-18/20 minimum fireplace size: 26 inches front width, 20 inches rear width, 15 inches depth, and 17 inches height.
  • G46-24 minimum fireplace size: 30 inches front width, 24 inches rear width, 15 inches depth, and 17 inches height.
  • G46-30 minimum fireplace size: approximately 35 to 36 inches front width, 29 inches rear width, 15 inches depth, and 17 inches height.
  • Rated input: approximately 40,000 BTU per hour for G46-18/20, 55,000 BTU per hour for G46-24, and 65,000 BTU per hour for G46-30.
  • Venting requirement: An open fireplace with a chimney and damper capable of venting combustion products.
  • Certification: Use only the burner, logs, controls, and accessories approved for the specific Real Fyre configuration.
  • Control choices: Configuration-dependent manual, standing-pilot, intermittent-pilot, or variable-flame controls.

Always use the rating plate and installation manual supplied with the exact burner and control package as the final authority.

How to Install and Set Up the G46 Vented Gas Log Set

  1. Confirm that the fireplace is approved for vented gas logs, is structurally sound, and has a functional chimney.
  2. Measure the front opening, rear width, depth, and height. Select a G46 size that meets or exceeds the required clearances without overcrowding the firebox.
  3. Verify that the burner fuel type matches the household gas supply. Do not connect a natural-gas burner to propane or vice versa unless the manufacturer-approved conversion procedure specifically permits it.
  4. Have a qualified gas professional install the shutoff valve, connector, pilot assembly, and control system in accordance with local codes.
  5. Position the burner level and centered according to the product manual. Do not cover burner ports, pilot openings, or ventilation areas.
  6. Install only the approved log set, placing each log on its designated support. Incorrect placement can produce soot, poor flames, or unsafe combustion.
  7. Open the chimney damper fully before lighting. A vented gas log set must never operate with the damper closed.
  8. Test the pilot, ignition, flame height, and gas connections. Apply an approved leak-detection solution to connections and correct any bubbling before operation.

Keep combustible materials, decorations, and fireplace screens positioned as directed by the manual. Never modify the burner or add unapproved media.

Troubleshooting the RH Peterson G46 Real Fyre Vented Gas Log Sets

Pilot Will Not Light

Confirm that the gas supply valve is open, the control is set correctly, and the pilot button is held for the required time. If the pilot still fails to remain lit, stop using the appliance and have the pilot assembly, thermocouple, thermopile, or gas pressure checked by a qualified technician.

Burner Does Not Ignite

Check that the pilot flame reaches the burner ignition area and that the control is compatible with the installed burner. Do not bypass safety switches or attempt to force ignition.

Small, Yellow, or Uneven Flames

Verify that the correct fuel type and inlet pressure are being used. Inspect the burner for debris and confirm that logs are positioned exactly as specified. A restricted chimney, closed damper, or incorrectly placed log can affect flame quality and produce soot.

Soot or Smoke Marks

Turn the system off and allow it to cool. Check log placement, burner cleanliness, and chimney draft. Persistent soot indicates a combustion or venting problem requiring professional service.

Preventive Maintenance and Support

Keep the burner and fireplace free of dust, arrange periodic inspection, and replace batteries in electronic controls when required. Warranty coverage varies by component; Real Fyre information lists longer coverage for many ceramic logs and vented burners, while valves, pilots, and controls generally have shorter limited coverage. Retain proof of purchase and contact RH Peterson or an authorized Real Fyre service professional for model-specific assistance.

Pros and Cons

Advantages

  • Realistic appearance: Compatible Real Fyre logs and the angled G46 burner can create a fuller, more natural-looking flame display than basic decorative burners.
  • Multiple sizes: The 18/20-inch, 24-inch, and 30-inch options accommodate different fireplace dimensions.
  • Fuel flexibility: Natural-gas and propane configurations are available when matched to the correct burner and controls.
  • Strong output: Rated inputs from approximately 40,000 to 65,000 BTU per hour provide substantial flame presence for a vented log set.
  • Control variety: Depending on configuration, users may choose manual, standing-pilot, intermittent-pilot, or variable-flame operation.
  • Category benefit: Compared with wood fires, gas operation avoids firewood storage, ash removal, and routine tending.

Limitations

  • Chimney required: The system must operate with a fully open damper and suitable venting, so it is unsuitable for sealed or unvented fireplaces.
  • Professional installation recommended: Gas connections, pilot systems, pressure checks, and log placement require careful setup.
  • Heat efficiency varies: Vented log sets emphasize appearance and flame realism, while some sealed gas appliances retain more heat indoors.
  • Compatibility matters: Mixing unapproved logs, media, burners, or controls can cause poor combustion and may void warranty coverage.
  • Best suited for: Homeowners who prioritize realistic flames and convenient operation in an existing vented fireplace.
  • Consider another appliance if: Maximum room heating, closed-chimney operation, or a sealed high-efficiency design is the primary goal.

Frequently Asked Questions

Does the G46 require a chimney?

Yes. The G46 is a vented gas log burner and requires an open fireplace with a chimney or other approved venting path.

Can the damper be closed while the logs are burning?

No. Keep the damper fully open whenever the burner is operating.

Can any gas logs be installed on the G46 burner?

Use only logs specifically approved for the selected G46 burner and control configuration. Follow the supplied placement diagram.

What should be checked before buying a G46 set?

Measure the fireplace opening and firebox, identify the available fuel, confirm chimney operation, and verify that the selected burner, logs, controls, and accessories are compatible.

Final Safety Reminder

The rh-peterson G46 Real Fyre Vented Gas Log Sets should be installed, inspected, and serviced according to the exact manufacturer instructions and applicable local codes. Stop operation immediately if you smell gas, observe soot, detect unusual flames, or suspect a blocked chimney. Leave the area, avoid electrical switches or open flames, and contact the appropriate gas utility or qualified service professional.

PDF

Faqs

How do I set up rh-peterson G46 Real Fyre Vented Gas Log Sets for the first time?

Have a qualified gas professional verify the fireplace, gas connection, burner model, and log configuration before installation. The fireplace must be level, properly sized, and connected to a working chimney. Turn off the gas before connecting the burner. Install the grate and log locators, then arrange the logs exactly as shown in the matching Real Fyre placement guide. Confirm that the chimney damper is fully open before lighting.

Can rh-peterson G46 Real Fyre Vented Gas Log Sets be installed in any fireplace?

No. The G46 burner is designed for a properly vented, wood-burning fireplace with a working chimney. Measure the fireplace opening, rear width, depth, and height against the requirements for the exact G46 size. The firebox should have a level, smooth floor and must not have an unsuitable ash lip or excessive recess. Never install the set in a sealed, unvented, or improperly sized fireplace.

Why must the damper stay open when using rh-peterson G46 Real Fyre Vented Gas Log Sets?

Vented gas logs require an open chimney path to exhaust combustion products safely. Keep the damper fully open whenever the rh-peterson G46 Real Fyre Vented Gas Log Sets are operating, and never modify or block the chimney. If smoke, soot, or unusual odors enter the room, turn the burner off, ventilate the area, and have the chimney and installation inspected by a qualified technician before using the fireplace again.

What should I do if my rh-peterson G46 Real Fyre Vented Gas Log Sets will not light?

First, confirm that the fireplace gas supply is on and that the control valve is set correctly. For electronic or remote-ready controls, replace weak batteries and check that the receiver and switch connections are secure. If the pilot does not ignite, do not repeatedly release gas into the firebox. Turn the system off and contact a qualified technician to inspect the igniter, pilot assembly, gas pressure, and safety controls.

Why does the flame on rh-peterson G46 Real Fyre Vented Gas Log Sets look too high or uneven?

Flame appearance can be affected by the control setting, gas type, burner alignment, log placement, and chimney draft. Make sure the logs are positioned according to the correct Real Fyre guide and are not covering burner ports. Do not rearrange logs while the set is hot or alter the burner. If the flame remains abnormal, produces excessive soot, or contacts the logs heavily, stop using the set and request professional inspection.

Can I use replacement logs or accessories with rh-peterson G46 Real Fyre Vented Gas Log Sets?

Use only Real Fyre logs, valves, controls, and accessories approved for the G46 burner and the specific gas configuration. A log set that physically fits may still create unsafe flame patterns or interfere with combustion. Confirm the burner model, natural-gas or propane setup, and listed accessories before purchasing replacements. A qualified installer should verify compatibility and perform the final log placement.

How can I improve the appearance and performance of rh-peterson G46 Real Fyre Vented Gas Log Sets?

Keep the chimney fully open, use the correct gas setting, and place every log on its designated locator or support. Avoid placing logs directly over burner ports unless the official placement diagram requires it. Ensure the grate is stable and centered in the firebox. A clean burner and correctly positioned logs provide more consistent flames and reduce soot. Never use the set with the glass doors closed unless the manual specifically permits it.

How should I clean and maintain rh-peterson G46 Real Fyre Vented Gas Log Sets?

Turn off the gas and allow the fireplace to cool completely before maintenance. Gently remove surface dust from the logs, grate, and burner using a soft brush or vacuum attachment; do not wash ceramic logs or disturb burner ports. Inspect the chimney, damper, pilot, wiring, and gas connections periodically. Have a qualified technician service the appliance when soot increases, flames change, controls malfunction, or the chimney shows blockage.