Rh-Peterson Real Fyre G18-16-18 Series Gas Log Set User Manual
Content
RH Peterson Real Fyre G18-16-18 Series Gas Log Set Manual
Introduction
The rh-peterson Real Fyre G18-16-18 Series Gas Log Set is an unvented gas log system designed to create the appearance and warmth of a traditional fireplace without cutting, hauling, or storing firewood. Its burner system is made for compatible 16- or 18-inch log arrangements and is available for either natural gas or propane, depending on the rating plate and selected configuration.
This gas log set combines a realistic flame pattern with a decorative fire bed that may include lava granules, glowing embers, and Bryte Coals. These components help distribute the flame visually across the fireplace and enhance the appearance of burning wood. Depending on the chosen control package, operation may be manual or may include remote flame-height adjustment and electronic ignition features.
The G18-16-18 Series is intended for homeowners replacing a wood-burning fire with a cleaner, more convenient decorative heating appliance. It can suit living rooms, family rooms, cabins, and other approved indoor fireplace installations. Because this is an unvented appliance, correct room sizing, ventilation, gas type, and installation are essential. The unit must be installed and serviced according to the official instructions and local building and fuel-gas requirements.
For homeowners searching for an RH Peterson Real Fyre G18-16-18 installation guide, the most important steps are confirming fireplace dimensions, matching the fuel type, arranging the logs correctly, and testing the pilot and burner before regular use.
Specifications
- Product family: Real Fyre G18 Series gas log burner system.
- Nominal size: 16/18-inch burner configuration.
- Appliance type: Unvented gas-fired heater.
- Fuel options: Natural gas or propane, as specified on the appliance rating plate.
- Maximum input: Up to 36,000 BTU per hour for applicable G18-16/18 configurations; confirm the exact rating on the installed model.
- Typical minimum fireplace dimensions: 24 inches front width, 20 inches rear width, 14 inches depth, and 17 inches height for the referenced G18-16/18 configuration.
- Fireplace room sizing: An unvented appliance requires adequate room volume. The official manual lists a minimum 225-square-foot room example for a 36,000-BTU installation with an 8-foot ceiling and no other gas-burning appliance.
- Included fire-bed materials: Lava granules, ember material, and Bryte Coals may be supplied depending on the package.
- Control choices: Manual controls, variable flame-height remote control with standing pilot, or electronic ignition with on-demand pilot may be available.
- Safety system: The burner assembly uses an oxygen-depletion safety pilot system on applicable unvented models.
How to Install and Set Up the G18-16-18 Gas Log Set
Installation should be completed by a qualified gas appliance technician. Do not connect a natural-gas appliance to propane or a propane appliance to natural gas. The gas type must match the rating plate.
- Confirm that the fireplace is approved for the selected unvented appliance and meets the required front width, rear width, depth, height, and room-volume clearances.
- Turn off the gas supply and allow the fireplace to cool completely. Inspect the firebox, gas line, shutoff valve, and combustion-air provisions.
- Position the burner assembly centrally and connect it to the correctly sized gas supply using approved fittings. Check every connection for leaks with a suitable leak-detection solution; never use an open flame.
- Install the control valve, receiver, or ignition components supplied with the selected control option. Keep electrical or control components away from excessive heat.
- Spread lava granules and ember materials only where directed by the official manual. Incorrect placement can affect flame appearance, soot production, or safe combustion.
- Place each log in its specified position. Logs must not block the pilot, burner ports, or oxygen-depletion sensor.
- Open the gas shutoff valve and follow the lighting instructions on the appliance label. Verify a stable pilot and even burner ignition.
- For remote models, install the specified batteries, pair the transmitter if required, and test ignition and flame adjustment.
Stop immediately if gas odor, delayed ignition, abnormal flame color, or soot appears. Turn off the appliance and contact a qualified technician.
Troubleshooting the RH Peterson Real Fyre G18-16-18
- Pilot will not light: Confirm that the gas shutoff valve is open, the control knob is in the correct position, and the ignition procedure is followed exactly. If the pilot remains out, allow the area to ventilate and request professional service.
- Pilot lights but will not remain on: The thermocouple, thermopile, gas supply, or oxygen-depletion safety system may require inspection. Do not bypass any safety device.
- Main burner does not ignite: Check that the control is set to the burner position and that the pilot flame reaches the sensor. A qualified technician should inspect the valve, wiring, receiver, and burner ports.
- Remote control does not respond: Replace batteries in the transmitter and receiver where applicable, confirm the control mode, and repeat the pairing procedure described for the installed control package.
- Uneven flames or soot: Turn the appliance off. Check for misplaced logs, blocked burner ports, excessive ember material, or an incorrect gas connection. Do not operate the set until the cause is corrected.
- Unusual odor or gas smell: Do not operate switches or create sparks. Leave the area and contact the gas supplier or emergency service according to local procedures.
The official G18 manual should be used for model-specific procedures because control layouts and ignition systems vary. For technical assistance, contact RH Peterson Technical Support at 1-626-369-5085, Monday through Friday, 7:00 a.m. to 4:00 p.m. Pacific Time. Keep the model, fuel type, serial information, and installation details available. Warranty service generally requires installation and maintenance records, so retain the purchase documentation and have service performed by qualified personnel.
Pros and Cons
Advantages
- Convenient operation: Gas ignition eliminates the preparation, ash, and cleanup associated with wood fires.
- Realistic presentation: Embers, lava granules, Bryte Coals, and carefully positioned logs create a more natural fire-bed appearance than a basic burner alone.
- Control flexibility: Available configurations may include manual operation, remote flame adjustment, standing pilot operation, and electronic ignition.
- Fuel flexibility: The G18 family supports natural-gas and propane versions, provided the appliance is ordered and installed for the correct fuel.
- Compact fireplace fit: The 16/18-inch format is suited to smaller approved fireplaces where larger log systems are unsuitable.
Limitations
- Professional installation required: Gas connections, clearances, room sizing, and log placement must be handled correctly.
- Unvented operating restrictions: The appliance depends on room air and must meet ventilation and room-volume requirements.
- Not a wood-burning replacement in every fireplace: Existing chimneys, fireboxes, and local regulations must be evaluated before conversion.
- Model variation: BTU input, controls, remote features, and operating procedures differ by exact suffix and fuel type.
- Best suited for: Homeowners seeking convenient decorative heat and realistic flames. Those wanting a fully vented installation, wood-fire experience, or different heating capacity may need another appliance category.
Safety and Maintenance
Read the complete owner’s manual before operating the RH Peterson Real Fyre G18-16-18 Series Gas Log Set. Keep combustible materials, decorations, and furniture outside the required clearance area. Never modify the burner, remove the oxygen-depletion safety system, obstruct the pilot, or use accessories that are not approved for the appliance.
Before each use, look for damaged logs, blocked burner ports, unusual corrosion, or changes in flame behavior. Keep the firebox free of dust and debris, but do not move logs or media while the appliance is hot. Arrange the logs exactly as shown in the installation instructions, and schedule inspection or servicing whenever ignition becomes unreliable, soot develops, or the flame pattern changes.
Faqs
How do I set up the rh-peterson Real Fyre G18-16-18 Series Gas Log Set for the first time?
Can the rh-peterson Real Fyre G18-16-18 Series Gas Log Set use natural gas or propane?
Why is the flame on my rh-peterson Real Fyre G18-16-18 Series Gas Log Set uneven or too small?
What should I do if the pilot will not stay lit on the rh-peterson Real Fyre G18-16-18 Series Gas Log Set?
Does the rh-peterson Real Fyre G18-16-18 Series Gas Log Set require a chimney or vent?
How can I reduce soot when using the rh-peterson Real Fyre G18-16-18 Series Gas Log Set?
How should I clean and maintain the rh-peterson Real Fyre G18-16-18 Series Gas Log Set?
How do I arrange the logs and embers for the best performance from the rh-peterson Real Fyre G18-16-18 Series Gas Log Set?