Designed for use in commercial and industrial settings, the Sealey EH3001 Industrial Fan Heater is a strong and efficient heating option. This heater offers effective and adaptable warmth with a 3kW power rating and two adjustable heat settings (1.5kW and 3kW). Along with standard safety features like overheat protection and a tip-over switch, it has an adjustable thermostat and a high-efficiency ceramic heating element. The EH3001 is a small, lightweight device that is perfect for big domestic environments like garages, workshops, and building sites.

Electric fan heater for industrial applications. Two heat settings with thermostat control, plus fan only setting. A totally dry heat with no condensation, no gas, no fumes, so no smell. Ideal for workshops, garages etc.

Specifications

  • Model: ...................................................................... EH3001
  • Voltage: ..........................................................................230V
  • Power rating: ...............................................................3000W
  • Heat Settings: .................................................1500W/3000W
  • Dimensions (W x D x H): .........................315 x 330 x 400mm
  • Fuse: ................................................................................16A

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

SAFETY

ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.

  1. The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
  2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators.
  3. If in any doubt about electrical safety, contact a qualified electrician.
  4. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and use a Portable Appliance Tester.
  5. Ensure that cables are always protected against short circuit and overload.
  6. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
    Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
    false.png DO NOT pull or carry the appliance by the power cable.
    false.png DO NOT pull the plug from the socket by the cable.
    false.png DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely. 
    Fit a new plug according to the following instructions (UK only).

    1. Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
    2. Connect the BROWN live wire to the live terminal ‘L’.
    3. Connect the BLUE neutral wire to the neutral terminal ‘N’.
    4. After wiring, check that there are no bare wires, that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
      Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.

    false.png DO NOT connect either wire to the earth terminal.

  7. Products which require more than 13amps are supplied without a plug. In this case you must contact a qualified electrician to ensure that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.
  8. If an extension reel is used it should be as short as possible and fully unwound before connection. A reel with an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of 2.5mm² section cable.

GENERAL SAFETY

WARNING! Disconnect the heater from the mains power supply, before servicing or performing any maintenance. Servicing or maintenance must only be carried out by an authorised service agent.

  • true.png Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts. 
  • true.png Use recommended parts only. Unapproved parts may be dangerous and will invalidate the warranty.
  • true.png Position the heater at least a minimum of 0.5mtr at the rear and sides, and 2mtr at the front, from any walls or objects. 

WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.

  • false.pngDO NOT obstruct the air inlet and outlet sections of the heater.
  • false.pngDO NOT cover the heater.
  • false.pngDO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
  • false.pngDO NOT touch the heater casing or grill when first switched off, as these will be very hot and will take time to cool.
  • false.pngDO NOT use the heater for anything other than its intended purpose. It is designed to provide heat in enclosed areas larger than 4m³, such as workshops and other industrial areas. It is not suitable for drying clothes or laundry.
  • false.pngDO NOT place the heater close to a bath, wash basin, shower, swimming pool or any other water-filled area or wet surface.
  • false.pngDO NOT get the heater wet or use in areas of high condensation.
  • false.pngDO NOT place the heater up against any surface such as a wall, door or furniture etc.
  • false.pngDO NOT place the heater immediately below any electrical outlet.
  • false.pngDO NOT allow the power lead to touch the radiator surface.

NOTE: Children of less than 3 years should be kept away unless supervised continuously.
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
NOTE: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

IMPORTANT! This unit is designed to raise the ambient temperature of an entire room, the temperature of the air coming out of the front of the heater will be warmer than the general temperature of the room, but there may not be a significant increase due to the large volume of air passing over the element. For the same reason, the element is hot during operation, but does not glow visibly. The room temperature depends on room size, insulation and the ambient temperature, which will increase as the room gets warmer.

Description

Large spaces may be heated rapidly and effectively with the high-performance fan heater Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings. This heater offers safe and dependable heating thanks to its cool-touch housing, two adjustable heat settings, and overheat safety. Its small size and portability make it simple to transfer and store, and its thermostat provides for accurate temperature control. For any garage, workshop, or industrial space, the Sealey Fan Heater 3kw 2 Settings EH3001 is a strong and adaptable heating option.

EH3001 OPERATION

  1. Position heater in an upright position on a firm surface and at a safe distance from any obstructions, flammable substances etc. Keep to a minimum of 0.5mtr clearance at the rear and sides, and 2mtr clearance at the front.
  2. Connect the heater to a suitable mains supply.
  3. Set the thermostat dial to the maximum setting (fully clockwise).
  4. The heater will switch on when the power setting selector is set to one of the two power settings.
    NOTE: It will take up to three minutes for the heater to reach optimum temperature.
  5. Once the room reaches the required temperature, turn the thermostat dial slowly counter-clockwise until the thermostat clicks, leave the dial in this position and the room temperature will be maintained at this setting. The heater will continue to operate until the power switch is turned to the OFF position.
  6. For fan only operation, turn the power/fan selector to the fan only setting and set the thermostat to its minimum setting.
  7. When not in use, disconnect the heater from the mains supply. Store it in a safe, dry, childproof location.

    operation_sealey_fan_heater_3kw_2_settings_eh3001.png

Setup Guide

Follow these easy instructions to use the Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings:

  1. Connect the heater to a regular wall socket.
  2. Adjust the heat to your preferred level using the adjustable switch.
  3. To get exact temperature control, adjust the thermostat.
  4. A safe, sturdy spot away from combustible objects is where you should put the heater.

MAINTENANCE

WARNING! Before attempting any maintenance, ensure that the unit is unplugged from the mains power supply and that it has cooled down.

  1. Clean the heater with a soft dry cloth only. DO NOT use abrasives or solvents.
  2. Periodically check the heater grille to ensure that it is not blocked.

    maintenance_sealey_fan_heater_3kw_2_settings_eh3001.png

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. 

IMPORTANT: No liability is accepted for incorrect use of this product.

Troubleshooting

Here are some common problems and solutions for the Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings:

  • Problem: The heater won't turn on.
  • Solution: Check the power cord for damage and ensure it is properly plugged into an outlet. If the problem persists, contact Sealey for further assistance.
  • Problem: The heater is producing a burning smell.
  • Solution: Turn off the heater immediately and allow it to cool. Check for any debris or foreign objects that may have fallen into the heater. If the problem persists, contact Sealey for further assistance.

Sealey Pros & Cons

  • Pros:
    • Adjustable heat settings and thermostat for precise temperature control
    • Overheat protection and cool-touch casing for safe operation
    • Compact and portable design for easy transportation and storage
    • Steel powder-coated finish for durability
  • Cons:
    • May be too powerful for smaller spaces
    • May produce a loud noise while operating

WARRANTY

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

Customer Reviews

The Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings is a customer favorite because of its safe operation, robust heating, and changeable settings. Some do, however, take issue with the heater's excessive wattage for compact places and its loud operating noise.

Faqs

What is the Sealey EH3001 Industrial Fan Heater's power rating?

With a Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings power rating, the heater is appropriate for heating bigger areas like garages and workshops.

Which heat settings are accessible on the EH3001?

You can adjust the heater's output between 1.5kW and 3kW to suit your demands thanks to its two heat settings.

Can I use the Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings for industrial purposes?

Its industrial design makes the heater sturdy and dependable for use in high-stress settings including warehouses, building sites, and workshops.

Is there an integrated thermostat in the heater?

Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings has a thermostat that you may regulate to the perfect temperature and keep it there.

Is there a portable heater?

Indeed, the carry handle and compact form of the Sealey Industrial Fan Heater 3kW 2 Heat Settings make it simple to transfer and adjust to the necessary position.

How soon does an area get heated from the heater?

Depending on the insulation and size of the room, the Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings potent fan and ceramic heating element enable it to heat up areas rapidly—usually in a matter of minutes.

What upkeep is necessary for the heater?

There is not much upkeep needed for the Sealey Industrial Fan Heater 3kW 2 Heat Settings. Maintain the air intake and exit clean on a regular basis to avoid dust accumulation and guarantee smooth functioning.

Does the heater use a lot of energy?

The Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings dual heat settings and adjustable thermostat, which efficiently control power use, are only two of its energy-efficient features.

Is it appropriate to use this Sealey Industrial Fan Heater 3kW 2 Heat Settings at home?

The heater is intended for industrial usage, but if it is operated properly and with safety precautions, it may also be utilized in big household spaces like garages and workshops.

Is there a warranty on the heater?

In order to provide peace of mind and cover manufacture flaws, the Sealey EH3001 Industrial Fan Heater 3kW 2 Heat Settings normally comes with a one-year warranty.