Installation: Vevor Swing Gate Opener MK1302 User Manual

Content

Overview

The Swing Gate Opener MK1302 is a DC-powered automatic operator for Class I vehicular swing gates, designed for residential driveways and similar vehicle-only access points. It supports both single and dual gate setups, with adjustable timing, soft start and soft stop movement, obstacle reversal, and compatibility with several optional accessories.

This guide is intended for users who need a practical, installation-focused manual for the Swing Gate Opener MK1302, including setup, wiring, remote learning, control board configuration, maintenance, and troubleshooting.

Specifications

  • Model family: MK1101 / MK1102 / MK1301 / MK1302 / MK1101M / MK1102M / MK1301M / MK1302M / MK1501M / MK1502M
  • Input power: 110V~120V/60Hz or 220V~240V/50Hz
  • Motor voltage: 24VDC
  • Power: 100W per actuator for MK1302
  • Current: 4A
  • Actuator speed: 20 mm/s
  • Maximum actuator travel: 385 mm or 15.2 in
  • Ambient temperature range: -22°C to +55°C
  • Protection class: IP44
  • Gate capacity: suitable for gates up to 400 kg and 5.5 m in length in the MK13 range, depending on gate weight and length
  • Control functions: dual/single gate mode, master/slave timing, auto-close, soft start, soft stop, obstruction sensing, and digital display settings
  • Control terminals: motor, limit, lamp, battery, photocell, push button, exit wand, lock, external receiver, and keypad connections

Detailed Description

The Swing Gate Opener MK1302 uses one or two linear actuators to move a hinged vehicle gate open and closed. In dual-gate installations, one opener acts as the master and the other as the slave, allowing staggered opening and closing if needed. The control board manages travel direction, timing, force, and safety responses through a digital display and button-based settings menu.

The system is built around a control box, actuator arms, mounting brackets, release key, and wiring connections for optional accessories. The opener supports pull-to-open and push-to-open installation styles. A manual release feature lets the gate be moved by hand during a power outage or service situation.

Compatible optional accessories include a backup battery, electric lock, wired and wireless push buttons, alarm lamp, exit wand, photocell beam system, solar controller, solar panel, wireless keypad, wired keypads, retro-reflective photocell, external receiver, and keypad mounting hardware.

Safety

The gate opener is meant for vehicular gates only, not pedestrian entrances. Pedestrian access should be separate and positioned away from the moving gate path. The gate must already operate smoothly by hand before the opener is installed, and all pinch points should be eliminated or protected.

Controls must be mounted at least 1.8 m from the gate so users cannot reach through, over, or around the moving leaf. Safety sensors should be used where entrapment risk exists, and warning placards should be installed visibly on both sides of the gate.

Do not connect the solar panel directly to the control board to charge the battery. Do not allow children to operate controls or play near the gate. Check the opener regularly to confirm safe operation, and keep the manual for future reference.

Setup and Operation

Installation preparation

The opener can be configured for pull-to-open or push-to-open use. Push-to-open requires a push-to-open bracket for each gate leaf. The mounting hardware can be used on round or square posts, and the post must be strong enough to remain stable under load. If the post is smaller than 6 inches in diameter or width, it should be metal and set in cement.

The post bracket position matters because it determines the opening angle. The gate opener should be mounted level, with enough clearance between the gate and the arm to avoid binding. A minimum clearance of 2.5 cm is required, and the arm must move freely in both open and closed positions.

Mounting and wiring

Install the control box in a protected, ventilated location, preferably at least 100 cm above the ground. Feed the power cable and actuator cables through the strain relief openings and keep the cable outlet facing downward so water can drain properly.

Do not connect power until all mechanical and electrical installation is complete. Use wire of at least 0.75 mm² for the AC supply connection. The opener’s power input accepts either polarity on the live and neutral lines.

Motor wiring

For pull-to-open operation, the actuator wires connect to the motor and limit terminals according to the labeled polarity and limit positions. For push-to-open operation, the motor and limit wires are connected differently, so the wiring must match the selected direction mode on the control board.

Optional accessories wire into dedicated terminals for alarms, batteries, photocells, push buttons, exit wands, electric locks, external receivers, and keypads. The photocell beam system is used for closing protection, and the push button cycles the gate through open, stop, close, stop, and open.

Remote learning and erasing

To pair a remote, press the learn button until the display shows the learn prompt, then press the remote key twice within 2 seconds. If pairing succeeds, the display confirms the learn state before returning to standby.

To erase all stored remotes, hold the learn button until the erase code appears and then release it. This clears all remote codes at once, which is useful if a transmitter is lost.

Control board settings

The control board uses a series of parameter screens for system setup. The main settings include single or dual gate mode, master/slave assignment, open and close delay between leaves, stall force, maximum motor running time, photocell enable or disable, auto-close time, soft start duration, fast running period, and factory reset.

The default single/dual setting is dual gate mode. The default master/slave assignment makes actuator 1 the master. Delay between leaves can be adjusted from 0 to 9 seconds. Stall force is adjustable in 9 levels, and each motor has a configurable running time of 1 to 50 seconds.

The photocell function can be turned on or off from the menu. If enabled, the gate will reverse when the beam is interrupted during closing. Auto-close can be set from 1 to 99 seconds, or disabled entirely. Soft start is adjustable from 1 to 9 seconds, and the fast running period can be set so the gate slows down near the end of travel for soft stop action.

After settings are complete, the controller returns to standby. The display shows different icons while the gate is moving, and the indicator changes depending on which motor is active and whether the gate is opening or closing.

Limit switch adjustment

Limit switch A is factory set and should not be changed. Limit switch B can be loosened and moved to set the desired closed position. The magnetic ring must remain between the two limit switches for correct operation.

How to use the opener

Once installation and setup are finished, the remote control can move the gate to the programmed open or close position. Pressing the remote while the gate is moving stops it immediately, and the next command reverses direction. If an obstruction is detected while opening, the gate stops; if it is detected while closing, the gate reverses to the open position.

Cleaning and Maintenance

Disconnect power before any service work. Wipe the actuator shaft with a clean, dry cloth and apply silicone spray to reduce friction. In cold weather, apply silicone more often to help prevent freeze-up.

Check hinges regularly to make sure the gate swings freely, and lubricate them if necessary. Inspect brackets, posts, and fasteners from time to time because hardware can shift after installation. Keep the gate area clear of debris and anything that could block movement.

Troubleshooting

If the opener does not power on, check the motor wiring, AC supply, and control board fuse. If the unit powers up but does not move, inspect the arm cable, confirm the arm is installed correctly, and make sure the gate is not too heavy or binding on its hinges.

If the gate starts and then stops right away, look for obstructions, reduce the chance of nuisance force detection, verify that the motor running time is not too short, and confirm the power supply is correct. If the gate opens but will not close, check whether the photocell function is enabled without the sensors being installed, and inspect the sensor alignment.

If the gate ignores the limit switches, check the switches, wiring, and possible electrical interference near the motor cable. If the gate opens, closes, or stops by itself, make sure the manual release key is locked in place.

Warranty

The Swing Gate Opener MK1302 is covered by a 12-month warranty from the date of purchase against defects in materials or workmanship. Coverage applies only when the product has been used and maintained according to the instructions, and it does not cover damage from accident, misuse, abuse, or unauthorized repair.

The owner is responsible for transportation costs to and from the authorized repair provider, and the unit remains at the owner’s risk while in transit.

Pros & Cons

  • Pros: Supports single and dual gate use, offers soft start and soft stop motion, includes obstacle reversal, and provides flexible timing and force settings.
  • Pros: Works with many optional accessories, including photocells, keypads, backup battery options, and an electric lock.
  • Pros: The digital display makes setup and status checking straightforward.
  • Cons: Installation requires careful alignment, correct wiring, and some mechanical skill.
  • Cons: Accessories such as extra cables and some mounting parts are not included for every site.
  • Cons: Safety and performance depend heavily on proper gate condition, hinge quality, and periodic maintenance.

The Swing Gate Opener MK1302 is best suited to users who want a configurable automatic gate system with strong safety features and room for future accessory expansion. With correct installation and routine maintenance, it can provide reliable daily operation for a residential vehicular swing gate.

PDF

Faqs

How do I choose between pull-to-open and push-to-open installation for the MK1302 swing gate opener?

The MK1302 supports both pull-to-open and push-to-open setups, but the gate must be matched to the right configuration before installation. Pull-to-open means the gate opens inward toward the property, while push-to-open means the gate opens outward. A push-to-open installation requires the correct push-to-open bracket on each gate. Also make sure the gate never swings into a public access area and that it moves freely before mounting the opener.

What gate size and weight can the Swing Gate Opener MK1302 handle safely?

The MK1302 is designed for heavier swing gates than the smaller MK11 series, but the exact capacity depends on gate length and weight. The manual shows the MK13 series, which includes the MK1302, as suitable for gates up to 400 kg for shorter leaf lengths, with lower weight limits as gate length increases. For best results, confirm that the gate moves smoothly on its hinges and stays within the supported length and weight range before installation.

Where should the MK1302 control box be installed for safe outdoor use?

The control box should be mounted in a well-ventilated location that is protected from rain and direct sunlight. The manual also recommends placing it at least 100 cm above the ground to reduce the risk of flooding or snow damage. Make sure the cable outlet faces downward so water can drain away. If possible, mount the box on a secure surface and use cable routing that fits your site layout without stressing the wires.

How do I connect the MK1302 motor wires for pull-to-open or push-to-open wiring?

Wiring depends on the installation direction. For pull-to-open, connect the actuator wires to the labeled motor, limit, and common terminals exactly as specified for each gate arm. For push-to-open, the motor wire polarity and limit-wire positions are different, so the connections must be swapped according to the push-to-open diagram. Always verify the wiring before powering on the system, because incorrect terminal placement can stop the opener from running properly.

How do I program a new remote control on the MK1302 gate opener?

To learn a remote, press the learn button once and wait for the display to show the learning indicator. Then press the remote button twice within two seconds. If the code is accepted, the display flashes briefly and returns to standby. If you need to erase all remotes, hold the learn button until the erase indicator appears. After clearing memory, every remote must be learned again for the system to work.

Why does the MK1302 gate opener stop immediately after starting, and how can I fix it?

A gate that stops right after moving usually points to one of three issues: an obstruction, force set too low, or a motor time setting that is too short. First check the gate path, hinges, and safety devices for anything blocking movement. Then increase the stall force gradually if the gate is heavy or stiff. If the opener still stops too soon, check the maximum motor running time setting and make sure the gate swings freely.

How should I adjust the limit switch on the MK1302 swing gate opener?

The manual says limit switch A is fixed at the factory and should not be moved. To set the closing point, loosen limit switch B with a screwdriver and slide it to the desired position while the opener is powered and running. Always keep the magnetic ring between the two limit switches. After adjustment, test the gate cycle to confirm that it stops where you want without binding or overtravel.

What routine maintenance does the MK1302 need to keep running smoothly?

Routine maintenance is simple but important. Wipe the actuator shaft with a clean, dry cloth, then apply silicone spray to reduce friction. In colder weather, the manual recommends repeating this more often to help prevent freeze-up. Also check the hinges so the gate swings freely, and lubricate them if needed. Finally, inspect brackets, posts, and hardware regularly because shifting or loosening can affect performance and safety.