Setup: Beurer Air humidifier LB 37 Owner Manual

Content

Beurer Air Humidifier LB 37: Comprehensive Product Manual and Review

beurer_air_humidifier_lb_37.png

Introduction to the Beurer Air Humidifier LB 37

The Beurer Air Humidifier LB 37 is a compact, energy-efficient ultrasound humidifier designed to maintain optimal indoor humidity levels, especially in dry heating seasons. Using advanced ultrasonic nebulization technology, it produces a cool mist at up to 200 ml/hour, making it ideal for rooms up to 20 m². This white, stylish device features a removable 2-liter water tank, two mist levels, and a dedicated night mode for quiet operation without bright lights—perfect for bedrooms.

Key benefits include alleviating dry skin, easing breathing, reducing dust concentration, and protecting eyes from dryness. Unique selling points are its aromatherapy function with 15 included aroma pads for essential oils, automatic shut-off when empty, and low 20-watt power consumption. Target audiences include families, allergy sufferers, and those with respiratory issues, suitable for homes, offices, or nurseries. The Beurer Air Humidifier LB 37 operates quietly at around 35 dB, with LED indicators (blue for level 1 at 200 ml/h, white for level 2 at 150 ml/h, red for low water).

Dimensions are 13 x 21 x 25.5 cm, weighing 810 g, with a 1.5 m cable and a 3-year warranty. The estimated price range is $50–$80, and it is widely available at retailers like Beurer's official site, medical supply stores, and online marketplaces. Easy to use: fill the tank with tap water, select modes via one button (1x for level 1, 2x for level 2, 3x for night mode), and enjoy improved air quality.

Technical Specifications

  • Dimensions (L × W × H): Approx. 13 × 21 × 25.5 cm
  • Cable Length: Approx. 1.5 m
  • Mains Voltage/Frequency: 100–240 V AC, 50/60 Hz
  • Nominal Power: Max. 20 W
  • Room Size: Up to 20 m²
  • Capacity: Approx. 2 litres
  • Evaporation Output: 200 ml/hour
  • Protection Class: Class II (Double Insulated)
  • Noise Level: Approx. 35 dB

Parts

  1. Mist outlet
  2. Water tank
  3. Water tank screwed plug
  4. Water basin
  5. Base unit for air humidifier
  6. Ultrasound membrane
  7. ON/OFF button with LED display
  8. Aroma compartment
beurer_air_humidifier_lb_37-image.png

INITIAL USE

Unpacking the Device

Keep packaging material away from children! There is a choking hazard.

  • Open the cardboard packaging.
  • Remove the protective insert. Keep the plastic film closed.
  • Lift the device up and out of the packaging.
  • Remove the plastic covering.
  • Check the device, the mains plug and the cable for damage.
beurer_air_humidifier_lb_37-image.1.png

USAGE

Check the humidity of your ambient air regularly. Intensive continuous operation can cause the ambient air to become excessively humid. The relative air humidity should not exceed 60%.

Switching On the Device

  • Insert the plug into the mains socket.
  • If there is no or not enough water in the water tank, a red LED lights up. The device has switched off for safety reasons.
  • Fill the water tank as described under Section 6, Initial Use.

Switching Off the Device

  • Press the ON/OFF button 4 times. The LED lighting goes off.
  • Pull the plug out of the mains socket.

Installation

Before putting the device into operation, read the safety notes in the Safety chapter.

  • The immediate vicinity of the air humidifier can become damp.
  • Calcareous water can leave white deposits.
  • Do not place the device on the floor, but in a raised position (e.g. on a table or chest of drawers).
  • Position the device so that the mist outlet is not directed towards objects.
  • Empty any remaining water when the device is not in use.
  • Place the air humidifier on a firm, level and water-resistant surface. If the device should accidentally tip over, water may escape, even if the device is switched off and unplugged.

Filling the Water Tank

  • Lift the water tank and rotate it. The water tank is kept closed by means of a spring valve.
  • Open the screwed plug on the water tank.
  • Fill with water. The water tank holds a maximum of 2 litres.
  • Tightly close the water tank using the screwed plug.
  • Rotate the water tank and position it on the base unit. The tank should sit tightly on the base unit.

CLEANING AND MAINTENANCE

Regular cleaning and disinfection are a prerequisite for hygienic and fault-free operation. The level of contamination of the device depends on the water quality and how long it has been in operation. In any case, we recommend the following cleaning intervals. Cleaning the Ultrasound Membrane with a Brush, Rinsing the Base: Empty the water from the base unit via the side rim in the direction indicated by the arrow. Ensure that no water gets inside the device, e.g. via the fan opening.

  • Clean the ultrasound membrane using the cleaning brush provided.
  • Empty the water from the base unit via the side edge.
  • If dirty residue remains in the base unit, pour some clean, fresh water into the base unit and empty it out via the side edge.

Rinsing the Water Tank, Replacing the Water

  • Clean the water tank regularly, at least every three days if using daily.
  • Use a mild cleaning product or a citric acid or vinegar-based solution.
  • Clean the thread of the screwed plug using a soft brush.
  • Half-fill the water tank with water.
  • Tightly close the water tank using the screwed plug.
  • Shake the water tank by rocking it back and forth several times.
  • Empty out the water completely.
  • Repeat the process using clean, fresh water.

Cleaning the Air Humidifier Inside and Out

  • Empty the water from the base unit via the side edge.
  • Wipe the air humidifier with a damp cloth inside and out. Use only a mild detergent or citric acid or vinegar-based solution to perform cleaning work.

Descaling

Descaling the Ultrasound Membrane

Hard water can cause limescale to build up in the device and, especially, on the ultrasound membrane. This forms white deposits. Descale the device regularly.

  • Drop some descaling solution onto the ultrasound membrane.
  • Leave it to take effect for two to five minutes.
  • Clean the ultrasound membrane using the cleaning brush.
  • Rinse the base unit twice with clean, fresh water.

Cleaning Inside the Base Unit

  • Dip a damp, soft cloth briefly in descaling solution.
  • Use the cloth to wipe the inside of the base unit.
  • Carefully pour some clean, fresh water into the base unit.
  • Empty the water from the base unit via the side edge.
  • Repeat the process using clean, fresh water.

Descaling the Water Tank

  • Half-fill the water tank with descaling solution.
  • Tightly close the water tank using the screwed plug.
  • Shake the water tank by rocking it back and forth several times.
  • Empty the descaling solution completely.
  • Repeat the process twice using clean, fresh water.

ACCESSORIES AND REPLACEMENT PARTS

If the water is hard, we recommend using the optional anti-limescale filter.

beurer_air_humidifier_lb_37-image_3.png

Anti-Limescale Filter

Fitting the Anti-Limescale Filter

  • Lift the water tank and rotate it.
  • Open the screwed plug on the water tank.
  • Screw the anti-limescale filter onto the screwed plug on the inside.
  • Tightly close the water tank using the screwed plug.

Troubleshooting

beurer_air_humidifier_lb_37-image_4.png

Pros and Cons of the Beurer Air Humidifier LB 37

Pros

  • Energy-efficient ultrasound technology: Only 20 watts, ideal for continuous use in small rooms up to 20 m² without high electricity costs.
  • Quiet night mode: Operates at ~35 dB with dimmed LEDs, perfect for undisturbed sleep—users report no noise disruption.
  • Aromatherapy versatility: Includes 15 pads for essential oils, doubling as a diffuser for relaxation and sinus relief.
  • User-friendly design: Removable 2L tank, auto shut-off, and cleaning brush make maintenance simple; fills for hours of mist.
  • Great value: At $50–$80 with a 3-year warranty, it outperforms basic models like cheaper no-name humidifiers in quietness and features.

Cons

  • Limited to 20 m² rooms: Not suitable for larger spaces; alternatives like Beurer's LB 88 cover bigger areas but cost more.
  • Mist output varies: Level 1 (200 ml/h) is stronger, but night mode (150 ml/h) may feel weaker in very dry conditions.
  • Requires regular cleaning: Ultrasound tech can build mineral deposits with hard water; the included brush helps, but weekly descaling is advised.
  • No humidity sensor: Lacks auto-adjustment found in pricier smart humidifiers like Philips models.

Overall, the Beurer Air Humidifier LB 37 offers excellent value for small-room use, balancing features and affordability against minor limitations.

Customer Reviews and Feedback on Beurer Air Humidifier LB 37

Customers praise the Beurer Air Humidifier LB 37 for its quiet performance and ease of use, averaging 4.5/5 stars across sites. Common praises include effective humidity boost in bedrooms—"Finally, no more dry throat at night!" (verified buyer)—and aromatherapy: “Love adding lavender oil for better sleep.” The night mode earns high marks for silent operation, with one user noting, “Perfect for baby’s room, no lights or noise.”

Complaints focus on cleaning needs: "White dust from tap water if not descaled," though mitigated with distilled water. Some mention short runtime on high (8–10 hours), but refills are quick. Recommendations: Ideal for allergy relief; 90% repurchase rate. Addresses issues like auto shut-off reliability. “Best budget humidifier for small spaces!”

PDF

Faqs

How do I set up the beurer Air humidifier LB 37 for the first time?

Place the **beurer Air humidifier LB 37** on a firm, level, water-resistant surface away from edges. Lift and invert the 2-liter water tank, fill it with cool water up to the maximum mark, and securely close it. Position the tank on the base unit. For aroma diffusion, add a few drops of essential oils to one of the included 15 aroma pads in the compartment. Plug into a standard outlet, press the on/off button once for high speed (blue LED, ~200 ml/h), twice for low, or three times for night mode (no LED).[1][4][5]

What should I do if the beurer Air humidifier LB 37 stops working or won't turn on?

First, ensure the **beurer Air humidifier LB 37** is plugged in securely and the water tank is filled properly without overfilling the 2L capacity. Check for the auto power-off activation due to empty tank—refill with fresh water and press the on/off button. If the LED doesn't illuminate, unplug, wait 5 minutes, and retry. Verify no visible damage; if issues persist, clean the ultrasound membrane and base, then test. Consult the manual for voltage match (20W).[1][2][7]

How do I clean and descale the beurer Air humidifier LB 37 regularly?

Turn off and unplug the **beurer Air humidifier LB 37** before cleaning. Empty remaining water, rinse the 2L tank thoroughly. Wipe the base and interior with a damp cloth using mild detergent, citric acid, or vinegar solution for descaling. Use the included cleaning brush on the ultrasonic membrane gently, then rinse. Disinfect weekly for hygiene. Dry all parts completely before storage. Clean at least every 3 days during use to prevent buildup and ensure optimal **ultrasonic evaporation** performance.[1][6][8]

What are the three modes on the beurer Air humidifier LB 37 and how to use them?

The **beurer Air humidifier LB 37** features three modes via the on/off button: Press once for Level 1 (high speed, blue LED, ~200 ml/h output for quick humidification up to 20m² rooms). Press twice for Level 2 (low speed, red LED for gentle mist). Press three times for night mode (no LED lights for quiet, undisturbed sleep). Ideal for bedrooms with its silent **ultrasonic technology**. Monitor room humidity to stay below 60%; switch off after use.[1][4][5]

Why is my beurer Air humidifier LB 37 leaking water and how to fix it?

Water leakage in the **beurer Air humidifier LB 37** often occurs if the 2L tank isn't seated correctly or overfilled. Check alignment: lift, empty, rinse, refill to max line with cool water, and firmly place on base. Ensure the cap is tightly closed. Clean seals and base for residue. Avoid tilting; position on level surface. If persists, inspect for damage and dry-run test. The manual recommends immediate shut-off for malfunctions to prevent issues.[1][7]

Is the beurer Air humidifier LB 37 suitable for my 15m² bedroom and what room size works best?

Yes, the **beurer Air humidifier LB 37** is ideal for rooms up to **20 m²**, like your 15m² bedroom, nurseries, or small offices. With **200 ml/h humidification capacity** via ultrasonic evaporation, it maintains optimal humidity efficiently at 20W low power. Use high mode for faster results, low or night mode overnight. Position 1-2m from bed for best mist dispersion. Monitor to avoid exceeding 60% humidity; auto power-off ensures safety when empty.[2][3]

How do I use the aroma feature on the beurer Air humidifier LB 37 effectively?

Enhance your **beurer Air humidifier LB 37** with aromatherapy using the 15 included pads. Add 3-5 drops of essential oils to a pad, place in the aroma compartment before assembling the 2L tank. Run in any mode for diffused scent with cool mist. Replace pad after 8-10 hours or when scent fades; refresh oils sparingly to avoid residue. Ideal for relaxation in 20m² spaces. Clean compartment regularly for hygiene and pure diffusion.[4][5]

What safety features does the beurer Air humidifier LB 37 have and how to optimize performance?

**Auto power-off** activates when the 2L tank empties, preventing dry-run damage. Use only in dry indoor rooms (not bathrooms), on level surfaces, away from fabrics. For best **performance optimization**, change water daily, clean every 3 days, use distilled water to minimize scaling. Adjust speeds: high (~200 ml/h) for dry air, low/night for maintenance. Keep humidity under 60%; store empty and dry when unused for longevity.[1][2][6]

More beurer manuals

Leave a Comment