Setup: Daewoo COL1319 Portable Air Conditioner User Manual
Content
Overview
The COL1319 Portable Air Conditioner is a mobile indoor cooling unit designed for rooms that need flexible temperature control without permanent installation. It combines cooling, dehumidifying, and fan-only operation, while the supplied exhaust kit removes warm air through a window, door, or another suitable outlet.
This portable air conditioner is suitable for users who want adjustable room cooling, selectable fan speeds, automatic timer operation, and remote control convenience. Because it uses R290 refrigerant and requires warm-air ventilation, correct positioning and safe hose installation are essential.
Specifications
- Model: COL1319
- Cooling capacity: 12,000 BTU/h, equivalent to 3.5 kW
- Refrigerant: R290, 215 g
- Rated voltage: 220–240 V
- Rated current: 6.0 A
- Rated power input: 1,345 W
- Weight: 24 kg
- Sound power level: 65 dB(A)
- Ingress protection: IPX0
- Maximum installation room area: More than 4 m²
- Compressor discharge operating pressure: 2.6 MPa
- Compressor suction operating pressure: 1.0 MPa
- Maximum discharge pressure: 3.2 MPa
- Maximum suction pressure: 1.2 MPa
Detailed Description
The COL1319 Portable Air Conditioner draws room air through its inlet, processes it through the refrigeration system, and releases cooled air through the front outlet. Warm air and much of the extracted moisture leave through the flexible exhaust hose.
The main components are arranged for straightforward operation and maintenance:
- Control panel: Provides access to power, operating mode, temperature, fan speed, and timer functions.
- LED display: Shows operating information, selected time settings, and water-full indications.
- Air inlets: Located on the cabinet sides and rear to draw air into the appliance.
- Air outlet: Releases conditioned air into the room.
- Cable storage: Provides a place to manage the power lead when the appliance is not being used.
- Hot-air exhaust: Connects to the supplied flexible hose.
- Condensed-water drain: Located at the lower rear of the unit for emptying the internal tank.
The cooling airflow leaves the appliance at a slight angle and to one side. This is normal and helps distribute cooled air around the room rather than sending it straight upward.
Safety
- Read all operating instructions before using the appliance and retain them for future reference.
- Inspect the unit, plug, and power cord for transit or physical damage before connecting it to the mains.
- Confirm that the voltage on the rating plate matches the local electrical supply. If the supply is unsuitable, have it checked by a qualified person.
- Use a properly installed wall socket. Do not connect the appliance through an extension lead, mains adaptor, or shared socket arrangement.
- Never operate the unit with a damaged plug or cord. Keep the cable away from sharp edges and do not stretch it.
- Disconnect the plug before cleaning, assembling, dismantling, or carrying out filter maintenance.
- Do not insert fingers, pencils, or other objects into the air grilles, and avoid contact with moving parts.
- Place the appliance on a dry, stable, level surface. Do not use it in a laundry area, bathroom, or other wet room.
- Keep children supervised. Children aged eight and above, and people with reduced physical, sensory, or mental abilities, may use the appliance only with suitable instruction or supervision.
- Do not spray the cabinet with water or immerse any part of the appliance.
- Operate and store the unit in a room larger than 4 m² and away from open flames, operating gas appliances, electric heaters, and other ignition sources.
- The appliance contains R290 refrigerant, which can present a fire or explosion hazard if leaked refrigerant accumulates in an unventilated room.
- Do not pierce, modify, or damage the refrigerant circuit. Repairs involving the refrigerant system must be performed by appropriately qualified personnel.
- Keep the unit upright during storage and transport. If it has been placed on its side or tilted significantly, wait at least 24 hours before restarting it.
- After switching the appliance off, wait at least three minutes before turning it on again to protect the compressor.
- Use the control-panel ON/OFF button to operate the appliance. Do not use the mains plug or an external timer as the regular on/off switch.
Setup and Operation
Positioning the Unit
- Place the air conditioner on a level, dry, stable floor.
- Leave at least 1 metre of clearance between the unit and walls or other obstructions on every side.
- Choose a location near a suitable mains socket, but do not use an extension lead or multiway adaptor.
- Keep the appliance away from direct sources of heat, open flames, and damp environments.
- Confirm that the air inlets and outlet are unobstructed before starting operation.
Installing the Exhaust Hose
The flexible exhaust hose must be fitted before using the appliance in cooling or dehumidifying operation.
- Extend approximately 10 cm of hose at one end.
- Screw the hose connector clockwise onto that end.
- Extend approximately 10 cm of hose at the other end.
- Screw the hose exit ring clockwise onto the second end.
- Hook the flat portion of the hose connector into the slot on the rear of the appliance.
- Move the connector toward the rear panel until its notches align with the locating tongues.
- Slide the connector downward until it locks into position.
- Place the hose exit through an open window, door, or another suitable outlet.
- Check that the hose is secure and does not have unnecessary bends or blockages.
Before powering on, verify that the hose is correctly attached, the appliance is upright, the floor is dry and level, and the electrical supply matches the rating plate.
Cooling Mode
- Press the ON/OFF button to start the appliance.
- Press the Mode button until the Cool indicator illuminates.
- Use the Temperature + or Temperature – button to select a target between 16°C and 31°C.
- Press the fan-speed button to select the desired airflow level.
For effective cooling, keep windows and doors closed as far as practical after the exhaust hose has been installed. Reduce direct sunlight with curtains or blinds when possible.
Dehumidifying Mode
- Turn on the unit with the power button.
- Press the Mode button until the Dehum indicator illuminates.
In this mode, the appliance automatically sets the temperature to 2°C below the detected room temperature and selects low fan speed.
Fan-Only Mode
- Press the Mode button until the Fan indicator illuminates.
- Use the fan-speed button to select the required airflow.
Fan mode circulates air without using the normal cooling setting, making it useful when air movement is wanted without active temperature reduction.
Timer Operation
The timer can start or stop the appliance after a selected number of hours. The LED display shows the delay from 0 to 24 hours.
- Delayed start: When the appliance is off, press Timer and use the Temperature/Time + or – button to select the desired start delay.
- Delayed stop: When the appliance is running, press Timer and use the Temperature/Time + or – button to select the desired stop delay.
To cancel an active timer, cancel the timer setting using the timer controls before normal operation continues.
Remote Control
The remote control duplicates the functions available on the control panel, allowing operation from a distance.
- Open the battery compartment by pushing back the retaining clip and removing the cover.
- Insert two AAA batteries, matching the polarity markings inside the compartment.
- Replace the battery cover securely.
- Do not mix old and new batteries.
- Remove the batteries if the remote will not be used for an extended period.
- Recycle used batteries through an appropriate collection facility rather than disposing of them with household waste.
Internal Water Tank and Drainage
During normal operation, much of the collected moisture is evaporated and expelled through the exhaust hose. Eventually, the internal tank may reach capacity. When this happens, the WF or Water Full indicator illuminates and the appliance may stop operating.
- Move the appliance outside or to a location suitable for draining water.
- Locate the drain bung at the lower rear left of the unit.
- Remove the bung and allow the tank to empty completely.
- Alternatively, attach a suitable drain hose and direct it to an appropriate drain.
- Replace the drain bung securely before using the appliance again.
Cleaning and Maintenance
Air Filter
The air filter is positioned behind the side air-inlet grille and requires periodic cleaning. A dirty filter can restrict airflow and reduce cooling performance.
- Pull the filter tab and slide the filter out in the indicated direction.
- Wash it in lukewarm water up to 40°C with a mild detergent.
- Rinse away detergent residue.
- Lay the filter flat and allow it to dry naturally so it does not stretch.
- Refit the filter only after it is completely dry.
Never operate the COL1319 Portable Air Conditioner without its filter installed.
Cabinet and Grilles
- Disconnect the appliance from the mains before cleaning.
- Wipe the exterior with a damp cloth and mild detergent.
- Use a vacuum cleaner with its nozzle attachment to remove dust from the grilles and exhaust area.
- Do not spray water into the appliance and do not immerse the unit in water.
Troubleshooting
- The unit will not start: Check the power supply and switch the appliance on. Empty the water tank if the Water Full indicator is illuminated. Cancel an active timer and check whether the selected temperature needs adjustment.
- Cooling performance is poor: Move the unit out of direct sunlight, clean the air filter, and remove obstructions from the air inlet or outlet.
- The compressor has stopped: The high-temperature protection may have operated. Check the exhaust path, clear any blockage, and allow the unit to cool for five minutes before restarting.
- The remote control does not work: Move closer to the appliance and replace the batteries if they are depleted.
- The appliance is noisy: Confirm that it is standing on a flat, level surface.
- E2 appears on the display: The water tank is full. Drain the tank and replace the drain bung before resuming use.
The unit also includes automatic high-temperature shutdown protection. If an air inlet or exhaust path is blocked, the appliance can shut down safely. Clear the obstruction and wait five minutes before attempting a restart.
Electrical Connections
The appliance is supplied with a fused three-pin BS 1363 plug. If the plug must be removed, cut it off and dispose of it immediately; never insert a removed plug into a mains socket.
If a replacement plug is fitted, the conductors must be connected correctly:
- Green and yellow: Earth terminal marked E.
- Blue: Neutral terminal marked N.
- Brown: Live terminal marked L.
Secure the outer cable sheath under the cord clamp, check that no wire strands are loose, and use only a 10 A BS 1362 fuse approved for the applicable standard. The plug cover must be fitted before the appliance is used. If there is any uncertainty, electrical work should be completed by a qualified electrician.
Pros & Cons
Pros
- Provides cooling, dehumidifying, and fan-only modes.
- Offers a broad temperature selection from 16°C to 31°C in cooling mode.
- Includes adjustable fan speed and 0–24-hour timer functions.
- Supports full operation from the supplied remote control.
- Uses a washable, removable air filter.
- Includes automatic high-temperature protection and a water-full indication.
Cons
- Requires an exhaust hose outlet through a window, door, or similar opening for normal cooling operation.
- Needs at least 1 metre of clearance from walls and obstructions.
- The internal water tank must be drained when the Water Full indicator appears.
- Operation may be interrupted if the air filter, inlet, or exhaust path becomes blocked.
- The unit is relatively heavy at 24 kg and must remain upright during transport and storage.
Faqs
How do I install the exhaust hose on the COL1319 Portable Air Conditioner?
What should I check before turning on the COL1319 air conditioner?
How do I use cooling mode on the COL1319?
How can I drain a full water tank on the COL1319?
How do I clean and replace the COL1319 air filter?
Why does the COL1319 shut down or show E2?
Why is the COL1319 not cooling effectively?
What safety precautions apply when moving or restarting the COL1319?
More daewoo manuals
- Setup: Daewoo HEA1 139 Flat or Upright Fan Heater User Manual
- Daewoo SDA1550 Deep Fat Fryer User Manual
- Setup: Daewoo HEA1 927 Fan Heater User Manual
- Daewoo 2-Slice Toaster SDA1674 User Manual
- How to Use: Daewoo Barista Espresso Maker With Milk Frother User Manual
- How to Use: Daewoo 5 in 1 Wireless Charger User Manual
Leave a Comment