Omron Compressor Nebulizer NE-C801KD Instruction Manual

cover-image

Content

Introducing the Omron Compressor Nebulizer NE-C801KD

This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebulizer kit. When the air enters the nebulizer kit, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled. This is a medical device. Operate the device only as instructed by your doctor and/or respiratory therapist.
NE-C801KD includes the kids accessories to enable children to feel more comfortable while inhaling. It improves compliance with drug treatment.

Priced at approximately $59.99, it offers an effective solution for managing respiratory conditions at home.

How the nebulizer kit works

The medication that is pumped up through the medication channel is mixed with compressed air which is generated by a compressor pump. The compressed air mixed with medication is turned into fine particles and sprayed when in contact with the baffle.

how_the_nebulizer_kit_works_omron_compressor_nebulizer_ne-c801kd.png

Intended use

CategoryDetails
Medical PurposeThis product is intended to be used for inhaling medication for respiratory disorders.
Intended User- Legally certified medical experts, such as doctor, nurse, and therapist.
 - Caregiver or patient under the guidance of qualified medical experts for home treatment.
 - The user should also be capable of understanding general operation of NE-C801KD and the content of the instruction manual.
Intended PatientsThis product should not be used by patients who are unconscious or are not breathing spontaneously.
EnvironmentThis product is intended for use in a medical facility, such as a hospital, clinic, doctor's office, or in a general household room.
Durable PeriodDurable periods are as follows, provided the product is used to nebulize 2 ml of medication 2 times a day for 6 minutes each time at room temperature (23°C).
 Durable period may vary depending on the usage environment.
Compressor (Main unit)5 years
Nebulizer Kit1 year (Cap, Inhalation Top, Vaporiser Head, Medication Tank)
Kids Accessory1 year
Mouthpiece1 year
Air Tube (PVC, 100cm)1 year
Air Filter60 days
Infant Mask (PVC)1 year
Child Mask (PVC)1 year
Precautions for UseWarnings and cautions described in the instruction manual should be observed.

Know your unit

know_your_unit_omron_compressor_nebulizer_ne-c801kd.png

Omron Compressor Nebulizer NE-C801KD Accessories

accessories_omron_compressor_nebulizer_ne-c801kd.png

Preparing the nebulizer for use

Warning

  • Clean and disinfect the nebulizer kit, kids accessory, mask or mouthpiece before using them for the first time after purchase.

  • If the device has not been used for a long period of time, or if more than one person uses the same device, clean and disinfect the nebulizer kit, kids accessory, mask or mouthpiece before using them.

Note: Make sure that the air filter is changed regularly. 

Connecting AC adapter

  1. Make sure that the power switch is turned off.
    Check that the power switch is in the off (powe_biutton_noco_smart_battery_charger_genius5.png) position.
  2. Insert the power plug of the AC adapter into the power connector on the compressor.
  3. Plug the AC adapter into a power outlet.

    connecting_ac_adapter_of_omron_compressor_nebulizer_ne-c801kd.png

    Note: When disconnecting the AC adapter, unplug the AC adapter from the power outlet before removing the power connector on the compressor.

Adding medication and assembling the parts

  1. Remove the mask or mouthpiece, kids accessory and cap from the nebulizer kit.
  2. Remove the inhalation top from the medication tank.
    1. Rotate the inhalation top anti-clockwise.
    2. Lift the inhalation top out of the medication tank.
  3. Add the correct amount of prescribed medication to the medication tank.
    Caution: The capacity of the medication tank is 2 to 7 ml.
    Note: Scales on the nebulizer kit are for reference only. The scale on the outside of the tank is with no vaporiser head in place. Please use the scale on your syringe or vial for accurate measurement of medication.
  4. Make sure that the vaporiser head is securely attached to the inhalation top.
  5. Put the inhalation top back inside the medication tank.
    1. Align the protrusion on the inhalation top with the indent on the medication tank, as shown.
    2. Rotate the inhalation top clockwise and align with the medication tank until they click in place.

      adding_medication_and_assembling_the_parts_omron_compressor_nebulizer_ne-c801kd.png
  6. Attach the cap, kids accessory, mask or mouthpiece to the nebulizer kit.
    1. Attach the cap to the inhalation air inlet.
    2. Attach the kids accessory to the inhalation top.
    3. Attach the mask or mouthpiece to the inhalation top.
      Note: If the amount of aerosol is too small, it is not necessary to place the cap.
  7. Attach the air tube.
    1. Twist the air tube plug slightly and push it firmly into the air tube connector on the compressor.
    2. Twist the air tube plug slightly and push it firmly into the air tube connector on the medication tank.

      adding_medication_and_assembling_the_parts_of_omron_compressor_nebulizer_ne-c801kd.png

      Notes:

      • Make sure that the air tube is securely attached to the compressor and nebulizer kit, and does not come loose. Twist the air tube plug slightly when inserting it into the air tube connectors to avoid the air tube disconnecting during use.
      • Take care not to spill the medication when attaching the air tube. Keep the nebulizer kit upright.

Taking medication

  1. Hold the nebulizer kit as indicated on the right.
    Caution: Do not tilt the nebulizer kit at an angle of greater than 45° in all directions. Medication may flow into the mouth or it may result in not nebulizing effectively.
  2. Press the power switch to the on ( I ) position.
    The compressor starts and nebulization starts.
    Note: Observe whether aerosol is generated.
    To stop nebulization
    Press the power switch to the off (powe_biutton_noco_smart_battery_charger_genius5.png) position.
    Warning:
    Do not cover the compressor with a blanket or towel etc., during use.
    Caution:
    • Do not block the air filter cover.
    • Limit use to 20 minutes at a time, and allow a 40 minute interval before using the device again.
    • When using the device, the main unit may become hot.
    • Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing.
      Note: Do not leave the compressor on for a long period of time. This could result in the compressor overheating or malfunctioning.
  3. Inhale medication according to your doctor’s and/or health care adviser’s instructions.
    • Attach the mask so that it covers your nose and mouth and inhale the medication.
    • Exhale through the mask.
    • Using the mouthpiece
    • Insert the mouthpiece into your mouth and inhale the medication breathing normally.
    • Exhale as normal through the mouthpiece.

      taking_medication_omron_compressor_nebulizer_ne-c801kd.png
  4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet.
    Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moisture. This could result in infection via bacteria.
    If there is moisture or liquid remaining in the air tube, be sure to follow the procedure below to remove any moisture from within the air tube.
    • Make sure that the air tube is still connected to the air connector on the compressor.
    • Unplug the air tube from the nebulizer kit.
    • Turn on the compressor and pump air through the air tube to expel the moisture.
      Use the nebulizer kit holder as a temporary holder for the nebulizer kit. 
      Note: Align the mark on the unit with the mark on the nebulizer kit as shown

      taking_medication_of_omron_compressor_nebulizer_ne-c801kd.png

Technical data

  • Name: COMP AIR
  • Model: NE-C801KD
  • Type: Compressor Nebulizer
  • Rating (AC adapter): 100 - 240V ~ 350mA, 50/60Hz Rating
  • (Compressor Nebulizer): 12V 0.8A
  • Operating Condition: Intermittent operation 20min. ON / 40min. OFF Operating Temperature/
  • Humidity: +10 to +40°C / 30% to 85%RH Storage Temperature/
  • Humidity/Air Pressure: -20 to +60°C / 10% to 95%RH / 700 - 1060 hPa
  • Weight: Approx. 270g (compressor only)
  • Dimensions: Approx. 142 (W) × 72 (H) × 98 (D) mm
  • Contents: Compressor, Nebulizer Kit, Kids Accessories (Smile Bear, Happy Bunny), Air Tube (PVC, 100cm), 5 pcs Spare Air Filters, Mouthpiece, Infant Mask (PVC), Child Mask (PVC), AC adapter, Carrying Bag, Instruction Manual.
  • Classification: Class ll equipment, Type B applied part
    • = Class ll equipment
    • = Type B applied part
    • Read the instruction manual carefully
    • = No operation
    • = Power on

Technical data for the OMRON NE-C801KD Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebulizer kit:

technical_data_for_the_omron_omron_compressor_nebulizer_ne-c801kd.png
  • Particle Size: **MMAD Approx. 3μm MMAD = Mass Median Aerodynamic Diameter
  • Medication Tank Capacity: 7ml maximum
  • Appropriate Medication Quantities: 2ml minimum - 7ml maximum
  • Nebulization Rate: *Approx. 0.3ml/min (by weight loss)
  • Aerosol Output: **0.47ml (2ml, 1%NaF)
  • Aerosol Output Rate: **0.06ml/min (2ml, 1%NaF)

Measured by OMRON HEALTHCARE Co., Ltd. Independently measured by Prof. Dr. Hiroshi Takano, Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering, Doshisha University, Kyoto, Japan, according to EN 13544-1:2007+A1:2009
Note: Performance may vary with drugs such as suspensions or high viscosity. See drug supplier’s data sheet for further details.

Optional parts and accessories

optional_parts_and_accessories_omron_compressor_nebulizer_ne-c801kd.png

Description

The Omron Compressor Nebulizer NE-C801KD is designed with user comfort and convenience in mind. The device is compact and lightweight, making it easy to move around. The nebulizer kit is BPA-free and dishwasher safe, ensuring easy cleaning and hygiene. The included mouthpiece and mask allow for versatile use, catering to both pediatric and adult patients. The tubing is long enough to provide flexibility while using the device, allowing patients to move around freely during treatment.

The compressor is built to last with a durable design that withstands frequent use. It also features a built-in filter to ensure clean air intake, enhancing the overall efficiency of the nebulization process.

QUICK MANUAL

quick_manual_omron_compressor_nebulizer_ne-c801kd.png

Please read the entire manual before using the device.
Warning: Clean and disinfect all the parts before using them.

  1. Adding medication 
    1. Rotate the inhalation top anticlockwise to remove.
    2. Add the appropriate amount of prescribed medication.
    3. Make sure the vaporiser head is securely attached to the inhalation top.
    4. Put the inhalation top back and rotate it clockwise until they click in place.

      adding_medication_omron_compressor_nebulizer_ne-c801kd.png
  2. Assembling kids accessory and mask
    Assemble the nebulizer kit as the following order.
    1. Cap
    2. Kids accessory
    3. Mask

      assembling_kids_accessory_and_mask_omron_compressor_nebulizer_ne-c801kd.png

      Warning: Do not let infants and children play with the kids accessory. Kids accessory is not a toy, but a component of nebulizer kit.

  3. Connecting AC adapter
    Insert the power plug of AC adapter into the power connector of the main unit. Plug the AC adapter into the power outlet.

    connecting_ac_adapter_omron_compressor_nebulizer_ne-c801kd.png
  4. Attaching air tube
    Attach the air tube to the main unit and to the nebulizer kit. When do so, twist and push it firmly.

    attaching_air_tube_omron_compressor_nebulizer_ne-c801kd.png
  5. Applying mask and starting inhalation
    Apply the mask securely. Turn on the power to the main unit.

    applying_mask_and_starting_inhalation_omron_compressor_nebulizer_ne-c801kd.png

    Use the nebulizer kit holder to place the nebulizer kit

    applying_mask_and_starting_inhalation_of_omron_compressor_nebulizer_ne-c801kd.png

Setup Guide

To operate the Omron Compressor Nebulizer NE-C801KD, follow these steps:

  1. Assembly: Connect the tubing to the compressor and attach the nebulizer kit to the other end of the tubing.
  2. Configuration: Fill the medication cup with the prescribed amount of medication and attach it to the nebulizer kit.
  3. Operation: Turn on the compressor and ensure that the nebulizer is producing a fine mist. Inhale the mist through the mouthpiece or mask as prescribed by your healthcare provider.
  4. Cleaning: After each use, clean the nebulizer kit according to the user manual instructions.

Important safety instructions

Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: 
Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.

(Usage)

  • For type, dose, and regime of medication follow the instructions of your doctor or respiratory therapist.
  • If you feel anything unusual during use, stop using the device immediately and consult your doctor.
  • Do not use only water in the nebulizer, for inhaling purposes.
  • Clean and disinfect the nebulizer kit, kids accessory, mask or mouthpiece before using them for the first time after purchase.
  • If the device has not been used for a long period of time, or if more than one person uses the same device, clean and disinfect the nebulizer kit, kids accessory, mask or mouthpiece before using them.
  • Be sure to wash the parts after use, and ensure that they are thoroughly disinfected and dried, and stored in a clean location.
  • Keep the device and kids accessory out of the reach of unsupervised infants and children. The device may contain small pieces that can be swallowed.
  • Do not let infants and children play with the kids accessory. Kids accessory is not a toy, but a component of nebulizer kit.
  • Do not store the air tube while there is moisture or medication remaining inside.
  • Do not leave the cleaning solution in the nebulizer parts. Rinse them with clean hot tap water after disinfecting.
  • Do not use or store the device where it may be exposed to noxious fumes or volatile substances.
  • Do not use the device where it may be exposed to flammable gas.
  • Do not cover the compressor with a blanket, towel, or any other type of cover during use.
  • Make sure that the nebulizer kit and kids accessory are clean before use.
  • Always dispose of any remaining medication after use, and use fresh medication each time.
  • Do not use in anaesthetic or ventilator breathing circuits.

(Risk of electrical shock)

  • Do not use the compressor or AC adapter while they are wet, or connect them to a power outlet or other devices with wet hands.
  • The compressor and AC adapter are not waterproof. Do not spill water, or other liquids, on these parts. If liquid does spill on these parts, immediately unplug the power cord and wipe off the liquid with gauze or other absorbent material.
  • Do not immerse the compressor in water or other liquid.
  • Do not use or store the device in humid locations, such as a bathroom.
  • Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device.
  • Do not operate the device with a damaged power cord or plug.
  • Keep the power cord away from heated surfaces.
  • Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” (page 24) in the Technical Data Section.

Cleaning and daily disinfecting

Cleaning

Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulizing effectively and also for preventing infections.
Warning:
Thoroughly rinse the nebulizer kit, kids accessory, mask or mouthpiece with clean hot tap water after each use, and disinfect them after the last treatment of the day.

  1. Make sure that the power switch is in the off (powe_biutton_noco_smart_battery_charger_genius5.png) position.
  2. Disconnect the AC adapter from the wall outlet and the compressor.
  3. Remove the nebulizer kit from the air tube and disassemble the nebulizer kit. Refer to Section 2 (page 12-13).
  4. Discard any remaining medication in the medication tank.
  5. Wash all the nebulizing parts in warm water and mild detergent and rinse in clean hot tap water.
  6. After cleaning and disinfecting the parts, rinse them thoroughly with clean water and allow the parts to air dry in a clean environment.
    Note: Do not start operation before the cleaned parts are completely dried.
  7. If the compressor or the outside of the air tube are dirty, wipe them clean with a soft cloth moistened with water or mild detergent.
    Caution: The compressor is not waterproof.
  8. Reassemble the nebulizer kit. Put it in the carrying bag.
cleaning_omron_compressor_nebulizer_ne-c801kd.png

Disinfecting the nebulizing parts

disinfecting_the_nebulizing_parts_omron_compressor_nebulizer_ne-c801kd.png
  • Always clean before disinfection. 
  • Always disinfect the medication tank, mouthpiece and other nebulizing parts after the last treatment of the day. For appropriate method of disinfecting each part, refer to page 18.

To disinfect the parts, use one of the methods described below:

A. Use a commercially available disinfectant. Follow the instructions provided by the disinfectant manufacturer.

  1. Submerge the parts in the cleansing solution for the specified period.
  2. Remove the parts and discard the solution.
  3. Rinse the parts with clean hot tap water, shake off excess water and allow to air dry in a clean environment.

B. Parts may be boiled between 15 to 20 minutes. After boiling, carefully remove the parts, shake off excess water and allow to air dry in a clean environment.
Note: Do not boil air tube, mask, kids accessory, air filter and air filter cover.

Caution: Do not use an autoclave, EOG gas disinfection or low temperature plasma sterilizer to disinfect the device.
Note: The printing may come off the surfaces of kids accessories as a result of repeated washing and disinfecting.

Handling the Vaporiser Head
The vaporiser head is an important part that is used to vaporise medication. Be sure to observe the following precautions when handling it.

handling_the_vaporiser_head_omron_compressor_nebulizer_ne-c801kd.png

Caution:

  • Always wash the vaporiser head after each use.
  • Do not use a brush or pin etc., to clean the parts.
  • When disinfecting the parts by boiling, be sure to boil them in plenty of water.
  • Do not boil vaporiser head together with other objects, other than applicable nebulizer accessories.
  • Do not use a microwave oven, dish dryer or hair dryer to dry parts.

Use the table below as a guideline to select a method for disinfecting.

cleaning_and_daily_disinfecting_omron_compressor_nebulizer_ne-c801kd.png

O: applicable ×: not applicable

An example of a commercially available disinfectant.

Maintenance and storage

To keep your device in the best condition and protect the device from damage follow these directions:

Caution:

  • Do not leave the device unattended with infants or persons who cannot express their consent.
  • Do not subject the device or the parts to any strong shocks such as dropping the device on the floor.
  • Do not carry or leave the nebulizer kit while the medication tank contains medication.

Notes:

  • Do not store the device in extreme hot or cold temperatures, high humidity or under direct sunlight.
  • Do not crease or fold the air tube.
  • Dispose of the device and any used accessories or optional parts according to applicable local regulations.
  • Never clean with benzene, thinner or a flammable chemical.

Always transport the device in its carrying bag, and store the device in the bag if it will not be used for a long period.

maintenance_and_storage_omron_compressor_nebulizer_ne-c801kd.png

Note: Nebulizer kit should be replaced after using for one year.

maintenance_and_storage_of_omron_compressor_nebulizer_ne-c801kd.png

Changing the air filter of Omron Compressor Nebulizer NE-C801KD

If the air filter has changed colour, or has been used on average for more than 60 days, replace it with a new one.

  1. Pull the air filter cover off the compressor.
  2. Change the air filter.
  3. Put the air filter cover back in place.
changing_the_air_filter_omron_compressor_nebulizer_ne-c801kd.png

Notes

  • Use only OMRON air filters designed for this device. Do not operate without a filter.
  • There is no front or back orientation for the air filters.
  • Check that air filters are clean and free of dust before inserting them.
  • Do not attempt to wash or clean the filter. If the air filter becomes wet, replace it. Damp air filters can cause blockages.
  • To prevent the air filter cover from becoming blocked, wash the cover regularly. Do not boil the air filter cover. Remove the air filter cover, wash it, and make sure it is dry and reattached correctly.
  • Please contact an authorized OMRON distributor for additional air filters, or if the parts supplied with the device are damaged or missing.

Troubleshooting

Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions.

Problem

Cause

Remedy

Nothing happens when the power switch is pressed.

Is the AC adapter connected correctly to the an electrical outlet and the compressor?

Check that the plug is inserted in an electrical outlet. Unplug then reinsert the plug if necessary.

No nebulization or low nebulization rate, when the power is on.

Is there medication in the medication tank?

Add the correct amount of medication to the medication tank.

Is there too much/little medication in the medication tank?

Is thevaporiser head missing and not assembled correctly?

Attach the vaporiser head correctly.

Is the nebulizer kit assembled correctly?

Assemble the nebulizer kit correctly.

Is the nozzle blocked?

Make sure that the nozzle is free of blockages.

Is the nebulizer kit tilted at a sharp angle?

Make sure that the nebulizer kit is not tilted at an angle of more than 45 degrees.

Is the air tube connected correctly?

Make surethat the air tube is correctly connected to the compressor and nebulizer kit.

Is the air tube folded or damaged?

Make sure that the air tube does not contain kinks.

Is the air tube blocked?

Make sure that the air tube is free of blockages.

Is the air filter dirty?

Replace the air filter with a new one.

The device is abnormally loud.

Is the air filter cover attached correctly?

Attach the air filter cover correctly.

The device is very hot.

Is the compressor covered?

Do not coverthe compressor with anytype of coverduring use.

Is the device operating continuously over 20 minutes?

Limit use to 20 minutes at a time, and allow a 40 minute interval before using the device again.

Note: If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. 
Please contact an authorized OMRON distributor.

Pros & Cons

Pros

  • Efficient Nebulization: Quick and effective nebulization rate ensures fast treatment sessions.
  • Quiet Operation: Less than 60 dB noise level makes it suitable for use in any environment.
  • Durable Design: Built to last with robust materials and a built-in filter for clean air intake.
  • Easy Cleaning: BPA-free and dishwasher-safe nebulizer kit for easy maintenance.
  • Versatile Use: Includes both mouthpiece and mask for use by pediatric and adult patients.

Cons

  • Size and Portability: Although compact, it may not be as portable as some other models due to its size and weight.
  • Power Dependency: Requires a power source to operate, which can be a limitation for travel or power outage situations.
  • Noise (Relative): While quieter than some models, it may still produce noticeable noise during operation.

Customer Reviews and Common Complaints

Customers have generally praised the Omron Compressor Nebulizer NE-C801KD for its effectiveness and ease of use. However, some common complaints include:

  • Size and Weight: Some users find it slightly bulky compared to other nebulizers on the market.
  • Noise Level: A few users have mentioned that while it is quieter than other models, it still produces some noise that can be bothersome in quiet environments.

PDF

Faqs

How do I assemble and configure the Omron Compressor Nebulizer NE-C801KD?

To assemble, connect the tubing to the compressor and attach the nebulizer kit. Fill the medication cup with the prescribed amount of medication and attach it to the nebulizer kit. Turn on the compressor and ensure that the nebulizer is producing a fine mist.

Is the Omron Compressor suitable for both pediatric and adult patients?

It includes both a mouthpiece and mask, making it suitable for use by pediatric and adult patients.

How do I clean the Omron Compressor Nebulizer NE-C801KD?

After each use, clean the nebulizer kit according to the user manual instructions. The nebulizer kit is BPA-free and dishwasher-safe for easy maintenance.

What are some key features of the Omron Compressor Nebulizer?

Key features include a piston-driven compressor, up to 0.4 mL/min nebulization rate, 3-5 micron particle size, less than 60 dB noise level, and power consumption of 120V, 50Hz, 45W.

Does the Omron Compressor Nebulizer require any special maintenance?

Regular cleaning of the nebulizer kit is recommended. The built-in filter also ensures clean air intake, enhancing overall efficiency.

Can I use the Omron NE-C801KD during travel?

While it is compact, it may not be as portable as battery-operated models due to its size and power dependency. However, it can still be packed for travel if necessary.

How long does a typical treatment session take with the Omron Nebulizer?

A typical treatment session can range from 5 to 15 minutes, depending on the prescribed medication and individual patient needs.

Is the Nebulizer NE-C801KD covered by insurance?

Coverage varies by insurance provider and policy. It is recommended to check with your healthcare provider or insurance company to determine if it is covered under your plan.

What kind of medication can be used with the Compressor NE-C801KD?

The Omron Compressor Nebulizer can be used with a variety of liquid medications prescribed for respiratory conditions. Always consult with your healthcare provider to ensure compatibility.

Air Fryer TXG-KK-DT10L-D-W

iW1 AirPlay wireless speaker system

Leave a Comment

Name

Email

Comment