Wahl Hot & Cold Vibratory Massager 4295-400 User Manual
Content
Wahl Hot & Cold Vibratory Massager 4295-400 Introduction
Wahl Vibratory Massager is a versatile therapeutic device designed to alleviate muscle tension and enhance relaxation. Featuring both hot and cold attachments, it promotes increased blood circulation and reduces inflammation for effective pain relief. With five additional massage heads, users can customize their experience from light soothing to deeper vibratory massages. This handheld massager is perfect for various body areas, and it is priced at $49.99, making it an accessible wellness tool.
Specifications
Massager comes with several key features that make it stand out:
- Dual Therapy: Offers both hot and cold therapy settings.
- Vibratory Massage: Provides multiple vibration modes for deep tissue massage.
- Adjustable Intensity: Allows users to adjust the intensity of the massage and therapy.
- Ergonomic Design: Designed for comfort and ease of use.
- Portable: Compact and lightweight, making it easy to carry.
- Safety Features: Includes automatic shut-off and thermal protection.
DESCRIPTION OF PARTS
DETACHABLE HEADS
- Deep Heat attachment
Smooth, wide heat applicator targets stiff and aching muscles - Cold Gel attachment
Cold gel, targets swollen joints and muscle inflammation. (Freeze attachment prior to use). - Triad attachment
Three points of added pressure to massage multiple areas at once. - Scalp stimulator
Delivers effective scalp massage and is soothing and relaxing. - Facial vitalizer
Provides beneficial, revitalizing facial massage. (Apply cold cream or lotion to face prior to use. Keep massager away from eyes.) - Spot attachment
Applies deep, pinpoint massage to a concentrated area. - Four Finger Flex attachment
Soft, finger-like nodes replicate a human touch.
Description
The Wahl Hot & Cold Vibratory Massager 4295-400 is a multifunctional device that combines the benefits of heat, cold, and vibration to provide comprehensive relief from muscle pain and stiffness. The device features a large treatment area, ensuring that it can cover significant portions of the body with ease. The hot therapy setting helps in relaxing muscles and improving blood circulation, while the cold setting is ideal for reducing inflammation and soothing sore areas. The vibratory massage function enhances the overall therapeutic experience by targeting deep tissue areas effectively.
OPERATING INSTRUCTIONS
- With the switch in the OFF position, plug the power cord into an AC outlet. (Make sure the voltage of power supply is the same as that indicated on massager.)
- Place the desired massage attachment on the massager. The attachments easily press on and pull off, if heat is desired, the heat attachment must be used. (See DEEP HEAT ATTACHMENT below). If cold massage is desired, the cold gel attachment must be used. (See COLD GEL ATTACHMENT below).
- Variable speed allows you to personalise your massage. For best results, begin at the lowest speed setting, and gradually increase to the desired massaging speed by rolling the dial toward the top of the massager. Roll the dial toward the bottom of the massager to decrease the speed.
- Push the top switch for the heat setting. Use heat only with the deep heat attachment. Heat may be applied alone or with the massaging feature.
- Apply the massager to the targeted area, using continual movement. A circular motion is often most effective. (See MASSAGE TECHNIQUES.)
CHANGING ATTACHMENTS
To remove an attachment head, grip firmly and pull. To insert an attachment head, place the head on the stem and press firmly.
DEEP HEAT ATTACHMENT
- To insert deep heat attachment, simply align the special track bar with the grooved section in the massager stem, then press firmly onto stem. To detach, use thumb and two fingers and pull away. When the deep heat attachment is correctly inserted, the heat element is automatically connected.
- If using the massager for the first time, begin with the lowest heat setting. Test the surface for a comfortable temperature. The massager will heat to the desired level within four minutes.
NOTE: When using heat, always check temperature before placing massager against skin. Everyone reacts differently to certain temperatures.
We suggest the following before use — check temperature by lightly touching with fingertips the silver heat plate on the massager. If uncomfortable to your touch, reduce temperature by (1) rubbing massaging surface onto a soft cloth, (2) moving the HEAT button to a lower setting, or (3) turning off unit for a short period before applying to your skin. Keep the massager moving constantly when the heat is on. - Never use heat on swollen or inflamed areas, or on skin eruptions.
NEVER use the heat applicator if the plastic housing is cracked or broken, or if the metal plate is loose, bent or lifted.
CAUTION: The two holes in the stem of the massager are like an electrical plug — electrical power is transmitted through them
NEVER allow water near the stem, and never insert anything into the holes.
WARNING: Always take care when using the heat setting to avoid burns and discomfort. Do not use on insensitive skin or in the presence of poor circulation.
COLD GEL ATTACHMENT
- Place gel attachment in the freezer prior to use.
- Freeze for 1-2 hours to allow the gel to reach the desired cold temperature or overnight. It will stay cold for 20-30 minutes and then remain cool.
- Attach securely to the massager, pressing into place. WARNING: Never apply the cold gel pack directly to the skin as it may cause ice burn.
- Test the surface for a comfortable temperature. If it is uncomfortable or becomes uncomfortable during use, stop using immediately.
- Apply to the targeted area, keep the massager moving, a gentle circular motion is recommended.
WARNING Never Heat the gel attachment or place in Microwave. This attachment is for cold use only. If the gel pack is accidentally punctured or torn, stop using immediately. If gel comes into contact with skin, wash with soap and water, if skin becomes irritated, or gel enters eyes or mouth, seek medical advise. - Keep the gel pack out of reach of children and pets.
Setup Guide
To operate the Wahl Hot & Cold Vibratory Massager 4295-400, follow these steps:
- Unbox the device and ensure all components are included.
- Plug in the device to a power outlet.
- Choose your desired mode (hot, cold, or vibratory) using the control panel.
- Adjust the intensity settings according to your comfort level.
- Apply the massager to the affected area and enjoy the therapeutic benefits.
- For hot therapy, allow the device to heat up for a few minutes before use.
- For cold therapy, ensure the cooling pack is properly inserted and secured.
CLEANING/STORAGE
- Always unplug massager before cleaning.
- Wipe unit with a dry, soft cloth.
- Do not immerse in water or use any harsh cleaners or solvents. When storing unit, ensure cord is not twisted or kinked.
MASSAGE TECHNIQUES
- SHOULDERS AND NECK
Massage each shoulder toward back of neck to point just behind and below ear. Then back to shoulder. Repeat several times. - ARMS
Start with a gentle massage of the palms and fingers. Next, using a circular motion, move upward to forearms. Then up to biceps and shoulders. - LEGS
If desired, massage bottoms of feet. Then, using a circular motion, massage each leg from calf on up and over thigh. - CHEST
Massage from centre of chest outward, and up toward each shoulder. - BACK
Massage from top of spine to bottom, and from centre outward. - ABDOMEN
Relax abdominal muscles by massaging from centre outward, using a gentle, circular motion. - JOINTS
Relieve tired, aching knees and elbows with smooth, circular strokes. - FACE
Gently massage from the nose outward, taking care to avoid contact with the eye.
WIRING
WARNING: If the supply cord is damaged it must be replaced by the manufacturers service agent or a similarly qualified person in order to avoid a hazard.
The wires in the mains lead are coloured in accordance to the following code:
- Blue Neutral (N)
- Brown live (L)
This product is fitted with a 3 pin plug which has a 3 amp fuse fitted. If the plug supplied is not suitable for your socket or becomes damaged, it should be cut off and disposed of, and a suitable plug fitted as detailed below. As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings identifying the terminals in your plug, proceed as follows. The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter ‘N’ or coloured BLACK or BLUE.
The wire which is coloured BROWN must be connected to the terminal in the plug which is marked with the letter ‘L’ or coloured RED or BROWN.DO NOT connect either wire to the terminal in the plug which is marked with the letter ‘E’ or has the Earth symbol, or coloured GREEN or GREEN/YELLOW.
If a 13 amp (BS 1363) plug is used, a 3 amp fuse must be fitted. If any other type of plug is used a 5 amp fuse must be fitted either in the plug or adaptor at the distribution board. Replacement fuses should be approved to BS 1362
Fuse cover must be refitted when changing the fuse. If the fuse cover is lost the plug must not be used until a replacement is obtained. Information for obtaining the correct fuse is marked on the carrier itself and in the bottom of the fuse cavity in the plug. These may be obtained from Wahl (UK) Ltd.
GENERAL USER INFORMATION
Information about using the operation manual
- Before using the appliance for the first time, you must read and understand the operation manual completely.
- Consider the operation manual as part of the product and store it in a safe and accessible place.
- Include this operation manual if passing the appliance on to a third party.
- In the case of conflicts with national safety specifications or instructions, the national requirements must be followed.
Explanation of symbols and notes
DANGER
Danger of electric shock which may result in serious physical injury or death.
DANGER
The danger of explosion which may result in serious physical injury or death.
WARNING
Warning of possible physical injury or a health risk.
CAUTION
- Information about danger of material damage.
- Note with useful information and tips.
- Action to be taken by owner.
- Carry out these actions in the sequence described.
- List
IMPORTANT SAFEGUARDS
When using this electrical appliance, especially when children are present, basic safety precautions should always be observed including the following.
Requirements
- This appliance should not be used by children and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Use this appliance only for its intended purpose as described in this manual. Do not use attachments not recommended by the manufacturer.
Hazards
Danger! Electric shock due to damage to the appliance
- Do not operate the appliance with a broken cord, plug or charger, or if the appliance malfunctions, or is dropped or damaged in any way.
- Any servicing or repair must be performed by Wahl (UK) Ltd or a suitably qualified professional.
- The use of attachments that are not supplied by the manufacturer may cause fire, electric shock or injury and damage to the appliance. Danger! Electric shock due to penetration of liquid.
- To protect against risk of electrical shock, never immerse the unit or let it come into contact with water or any other liquids. Do not use the unit with wet hands. If the appliance should become wet, damp or fall in water, remove plug from mains socket immediately. Do not put your hands in the water. Do not take into bathroom.
Danger of explosion
- Never use the appliance where aerosol (spray) products are being used or where oxygen is released.
Warning! Injuries due to incorrect handling - Switch off the appliance and unplug from outlet when not in use, before putting on or taking off attachments and also before cleaning the appliance.
- Never use your appliance without paying attention! Always unplug this appliance from the electricity outlet immediately after using.
- In case of pregnancy, diabetes or illness, consult your physician before using this massager.
- Do not use the massager on:
- Sensitive skin, swollen or inflamed areas, in the presence of poor circulation, where skin eruptions are present, or in the presence of unexplained calf or abdominal pain.
- Varicose veins.
- The front of the neck.
- Genital areas.
- Sleeping or unconscious persons.
- When using a massage attachment be sure to seat the attachment fully onto the stem and keep it on while massaging.
- Do not use the massager for more than 20 minutes at one time.
- Do not use the massager in close proximity to loose clothing or jewellery.
- Keep long hair away from massager while in use.
- This massager contains an electro-magnetic motor. To avoid risk of injury, it must not be used within 15cm of an implantable cardiac device.
- Do not use the massager without attachments.
- Do not operate this appliance under a blanket or pillow. Excessive heating can occur and cause fire, electric shock or injury.
Caution! Danger of product damage - Do not wrap the cord around the appliance.
- Do not use outdoors or in damp areas.
- Never carry the unit by its power cord.
- Do not drop or insert any object into any opening.
- Use this appliance only for its intended purpose.
- Keep the massager away from heated surfaces.
Troubleshooting
If you encounter any issues with your Wahl Hot & Cold Vibratory Massager 4295-400, here are some common problems and their solutions:
- Device Not Turning On: Check if the device is properly plugged in and ensure there are no power issues.
- Heating/Cooling Issues: Ensure that the heating or cooling elements are properly installed and functioning correctly.
- Vibration Not Working: Check if the vibration setting is selected correctly and if there are any blockages preventing vibration.
- Warning Instructions: Always follow safety guidelines provided in the user manual to avoid any injuries or damages.
GUARANTEE
This product is guaranteed against defects in material and workmanship for a period of 2 years from the date of original purchase or receipt as a gift.
Wahl Hot & Cold Vibratory Massager 4295-400 Pros & Cons
Pros
- Multi-Functional: Offers hot, cold, and vibratory therapies in one device.
- Ergonomic Design: Easy to use and comfortable to handle.
- Portable: Lightweight and easy to carry around.
- Adjustable Settings: Allows users to customize their massage experience.
- Affordable: Priced competitively compared to other similar products on the market.
Cons
- Limited Coverage Area: May not be suitable for larger areas of the body.
- No Batteries Included: Must be plugged into a power outlet for use.
- No Carrying Case Included: Users may need to purchase a separate case for storage and travel.
Customer Reviews
Customers have generally praised the Wahl Hot & Cold Vibratory Massager 4295-400 for its effectiveness in relieving muscle pain and stiffness. Many appreciate its ease of use and the multiple therapy options available. However, some users have noted that the device could be larger to cover more area at once. Here are some common complaints: - Some users find it a bit heavy when using for extended periods. - A few users have reported issues with the heating element not warming up quickly enough.
Faqs
How do I clean the Wahl 4295-400?
Can I use the Wahl Hot & Cold on sensitive skin?
Is the Wahl Vibratory Massager suitable for pregnant women?
How long does it take for the heating element to warm up?
Does the Massager come with a warranty?
How often should I use the Wahl Hot & Cold?
Can children use this massager?
Is there an automatic shut-off feature?
Where can I purchase replacement parts?
Leave a Comment