Setup: Beurer Nebuliser IH 58 User Manual
Content
Beurer Nebuliser IH 58: Comprehensive Product Manual and Guide

Introduction to the Beurer Nebuliser IH 58
The **Beurer Nebuliser IH 58** is a compact, ultra-portable medical device designed for effective treatment of respiratory conditions using compressed air technology. This lightweight nebulizer, weighing just 176 grams and measuring 110 x 62 x 47 mm, delivers a high nebulization performance of approximately 0.25 ml/min, producing fine aerosol particles (MMAD 4.12 µm) that reach deep into the upper and lower airways. Ideal for colds, asthma, rhinitis, sinusitis, and other respiratory diseases, it ensures short inhalation times and a high proportion of respirable particles for targeted therapy.
Key benefits include whisper-quiet operation at a maximum sound pressure of 45 dBA, making it suitable for home use or travel without disturbing others. The **Beurer IH 58 nebuliser** features single-button operation, an integrated LED indicator, and easy disassembly for disinfection, promoting hygienic use. It comes with extensive accessories: adult and child masks, mouthpiece, compressed air hose, 10 replacement filters, storage bag, and a year pack for ongoing maintenance. Powered via a universal mains adapter (100-240 V, 5 V / 2 A output) with a 1.5m micro USB cable, it's perfect for families treating children and adults.
Targeted at individuals with chronic respiratory issues, parents of young children, and frequent travelers, the **Beurer nebuliser IH 58** offers quick relief by nebulizing liquid medications efficiently, reducing systemic side effects. With a 5-year warranty and expected service life of 400 hours, it's a reliable choice. The estimated price range is ₹5,615 to around $100-150, widely available at medical online shops like Praxisdienst, Beurer official site, and retailers such as Amazon or Medikart.
Specifications
- Type: IH 58
- Dimensions (W × H × D): 110 × 62 × 47 mm
- Weight: 176 g
- Operating Pressure (with Medication Container): Approx. 0.25 to 0.50 bar
- Operating Pressure (without Medication Container): Approx. 0.35 to 0.6 bar
- Atomiser Filling Volume (Minimum): 2 ml
- Atomiser Filling Volume (Maximum): 6 ml
- Medication Flow Rate: Approx. 0.25 ml/min
- Sound Pressure: Max. 45 dBA (according to DIN EN 13544-1, Section 26)
- Mains Connection Input: 100–240 V AC, 50–60 Hz, 0.5 A
- Mains Connection Output: 5 V DC, 2 A
- Expected Service Life: 400 hours
Operating Conditions:
- Temperature: +10°C to +40°C
- Relative Humidity: 10% to 95%
- Ambient Pressure: 700 to 1060 hPa
Storage and Transportation Conditions:
- Temperature: -20°C to +60°C
- Relative Humidity: 10% to 95%
- Ambient Pressure: 700 to 1060 hPa
Aerosol Properties:
- Aerosol Delivery: 0.15 ml
- Aerosol Delivery Rate: 0.03 ml/min
- Particle Size (MMAD): 4.12 μm
DESCRIPTION OF THE DEVICE AND ACCESSORIES
Overview of Nebuliser:
- On/Off Switch
- Micro USB Port
- Holder for Atomiser
- Filter Cap with Filter
- Hose Connector
Overview of Atomiser and Accessories:
- Compressed Air Hose
- Atomiser
- Medication Container
- Atomiser Insert
- Atomiser Attachment
- Mouthpiece
- Adult Mask
- Children's Mask
- Nosepiece
- Replacement Filter
- USB Cable
INITIAL USE
Setting Up the Device
- Take the device out of the packaging.
- Place the device on a flat surface.
- Before Using the Device for the First Time
Note
- Clean and disinfect the atomiser and accessories before using them for the first time. See “Cleaning and Disinfection”.
- Connect the compressed air hose 6 to the bottom of the medication container 8.
- Connect the other end of the compressed air hose 6 to the nebuliser hose connection 5 by turning it slightly.
Switching On the Nebuliser
To turn on the nebuliser, proceed as follows:
- Plug the micro USB cable included in the delivery into the micro USB port on the nebuliser. Plug the other end of the micro USB cable into the USB port on the mains adapter and insert the mains adapter into the socket.
- Press the ON/OFF button on the nebuliser. The ON/OFF button illuminates blue. The nebuliser is now operational.
Operation
- For hygiene reasons, it is essential to clean the atomiser 7 and the accessories after each treatment and to disinfect them after the last treatment of the day.
- The accessories may only be used by one person; use by several people is not recommended.
- If the treatment involves inhaling several different medications one after the other, please be aware that the atomiser 7 must be rinsed under warm tap water following every usage. See “Cleaning and Disinfection”.
- Please observe the notes on changing the filter in these instructions for use.
- Check that the hose connectors are firmly attached to the nebuliser 5 and the atomiser 7 before each use of the device.
Inserting the Atomiser Insert
- Open the atomiser 7 by twisting the top anticlockwise against the medication container 8. Place the atomiser insert 9 into the medication container 8.
- Ensure that the cone for administering medication fits well on the cone for the air duct inside the atomiser.
Filling the Atomiser
- Fill with an isotonic saline solution or pour the medication directly into the medication container 8. Avoid overfilling. The maximum recommended filling quantity is 6 ml.
- Use medication only as instructed by your doctor and ask about the appropriate inhalation period and quantity for you.
- If the prescribed quantity of medication is less than 2 ml, top this up to at least 2 ml with isotonic saline solution. Dilution is also necessary with viscous medications. Here too, please observe the instructions of your doctor.
Closing the Atomiser
- Close the atomiser 7 by twisting the top clockwise against the medication container 8. Ensure that the connection is correct.
- Connecting Accessories to the Atomiser.
- Connect the atomiser 7 to the desired accessory (mouthpiece 11, adult mask 12, children’s mask 13, or nosepiece 14).
In addition to the accompanying adult mask 12 and children’s mask (from 2 years of age) 13, you also have the option of using a baby mask (from ages 0–3 years) with your nebuliser. The baby mask is not included in the delivery with the IH 58. You can find an overview of all replacement items in the chapter “Replacement Parts and Wearing Parts”.
Note: The most effective form of nebulisation is by using the mouthpiece. Nebulisation using a mask is only recommended if it is not possible to use a mouthpiece (e.g., for children who are not yet able to inhale medication using a mouthpiece).
Treatment
- When inhaling, sit upright and relaxed at a table and not in an armchair to avoid compressing the airways and therefore impairing the effectiveness of the treatment.
- Breathe in the atomised medication deeply.
Important
The device is not suitable for continuous operation; after 30 minutes of operation, it must be switched off for 30 minutes.
Note: During the treatment, hold the atomiser straight (vertically); otherwise, the atomisation will not work, and faultless functionality is not guaranteed. Depending on the battery charge status and accessory used, the inhalation time stated may vary.
Important
Essential oils, cough syrups, gargling solutions, and drops to be used as a rub or in a steam bath are wholly unsuitable for inhalation using a nebuliser. These additions are often viscous and can impair the correct functioning of the device and, therefore, the effectiveness of the application in the long term. For individuals with a hypersensitive bronchial system, medications containing essential oils may, under certain conditions, cause an acute bronchospasm (a sudden cramp-like restriction of the bronchi with shortness of breath). Consult your doctor or pharmacist in relation to this matter. Stopping Inhalation Once the mist is only coming out in an irregular flow or if the sound changes when inhaling, you can stop the treatment.
- Switch off the nebuliser after treatment using the On/Off switch 1 and disconnect it from the mains.
- Place the atomiser 7 back in its holder 3 after the treatment.
Changing the Filter
In normal operating conditions, the air filter must be replaced after approx. 100 operating hours or one year. Please check the air filter regularly (after 10–12 nebulisation procedures). Replace the used filter if it is very dirty or clogged. If the filter has become damp, it must also be exchanged for a new filter.
Important
- Do not attempt to clean the used filter and reuse it.
- Only use the manufacturer’s original filter, otherwise your nebuliser may become damaged, and sufficiently effective treatment cannot be guaranteed.
- Do not repair or maintain the air filter while it is in use.
- Never operate the device without a filter.
Pull off the filter cap 4 towards the front
Note: If the filter remains in the device after the cap has been removed, take the filter out of the device, e.g., with tweezers or similar.
- Re-insert the filter cap 4 with a new filter.
- Ensure that it is securely in place.
CLEANING AND DISINFECTION
Preparation
- Immediately after each treatment, all parts of the atomiser 7 and the accessories used must be cleaned of residual medication and contamination.
- Disassemble the nosepiece if you have used it with the comfort attachment.
- To do this, dismantle the atomiser 7 into its individual parts.
- Remove the mouthpiece 11, the mask 12 or 13, or the nosepiece 14 from the atomiser.
- Dismantle the atomiser 7 by twisting the top anticlockwise against the medication container 8.
- Remove the atomiser insert 9 from the medication container 8.
- Reassembly is carried out in reverse order.
Cleaning
The device must be switched off, disconnected from the mains, and allowed to cool down each time before cleaning. The atomiser and the accessories used, such as the mouthpiece, mask, etc., must be washed with hot but not boiling water after each use. Dry the parts carefully using a soft cloth. Put the parts together again when they are completely dry and place them in a dry, sealed container, or disinfect them. When cleaning, ensure that any residue is removed. Never use any substances for cleaning that could potentially be toxic if they came into contact with the skin or mucous membranes, or if they were swallowed or inhaled. Use a soft, dry cloth and non-abrasive cleaning products to clean the device.
Condensation, Hose Care
Condensation may form in the hose depending on the ambient conditions. It is essential to remove the moisture to prevent bacterial growth and ensure proper treatment. To do so, proceed as follows:
- Remove the compressed air hose 6 from the atomiser 7.
- The hose must remain connected to the nebuliser 5.
- Operate the nebuliser until the moisture is removed by the air passing through.
- In the event of heavy contamination, replace the hose.
Disinfection
Please carefully observe the points below when disinfecting your atomiser and atomiser set. We recommend disinfecting the individual parts on a daily basis after the last usage as a minimum measure. (All you need for this is a little white vinegar and distilled water. Ethanol 70 vol% can also be used for 10 minutes to disinfect the PVC masks and the air tubes.)
- First, clean the atomiser and atomiser set as described in the “Cleaning” section.
- Place the disassembled atomiser 7, the mouthpiece 11, the masks 12 and 13, and the nosepiece in boiling water for 3 minutes.
Durability of Materials
- As with any plastic parts, atomisers and their accessories are affected by a certain amount of wear and tear when used and hygienically prepared on a frequent basis. Over time, this can lead to a change in the aerosol, which can have a negative effect on the efficiency of the treatment. We therefore recommend that you replace the atomiser and other accessories after a year.
- The following point should be observed when selecting the cleaning product or disinfectant: only use a mild cleaning product or disinfectant in the concentration and volume prescribed by the manufacturer.
Storage
- Do not store in damp conditions (such as in a bathroom) and do not transport with any damp items.
- When storing and transporting, protect from prolonged direct sunlight.
- The accessories can be stowed securely in the accessory compartment. Store the device in a dry place, ideally in the original packaging.
TROUBLESHOOTING



Pros and Cons of the Beurer Nebuliser IH 58
Pros
- High Performance in Compact Design: Nebulization rate of 0.25 ml/min with 0.25-0.5 bar pressure ensures fast, effective treatment for upper/lower airways, outperforming bulkier models.
- Ultra-Portable and Quiet: Palm-sized (176g), 45 dBA noise level ideal for travel and discreet use, unlike louder traditional nebulizers
- Comprehensive Accessories: Includes masks for adults/children, mouthpiece, filters, and storage bag; supports babies with optional parts.
- User-Friendly and Hygienic: One-button operation, easy cleaning, automatic cut-out for safety; great value with 5-year warranty.
- Versatile Power: Worldwide mains compatibility via micro USB, perfect for global travel
Cons
- Limited Reservoir: Atomiser holds 2-6 ml, requiring refills for longer sessions compared to larger nebulizers.
- Mains-Only Operation: No battery option, less ideal for areas without power outlets, despite portability
- Maintenance Needs: Regular filter changes and thorough cleaning of parts (no immersing the hose) to prevent blockages, as noted in user guides.
Overall, the **Beurer Nebuliser IH 58** offers excellent value for money at its price point, surpassing alternatives like basic ultrasonic models in particle delivery and quietness, though heavier units may suit extended clinical use better.
Customer Reviews and Feedback on Beurer Nebuliser IH 58
Users praise the **Beurer IH 58 nebuliser** for its portability and efficiency, with an average rating of 4.5-4.8 stars across sites like Amazon and medical retailers. Common highlights include "whisper-quiet operation" and "quick treatments under 10 minutes," ideal for kids with asthma: “My child sleeps through sessions—game-changer for travel!” Parents appreciate the child mask and lightweight design: “Fits in my bag perfectly; high performance for the size.”
Frequently mentioned praises: effective for colds and allergies, easy cleaning, and a reliable year-round pack. Complaints are minor, like occasional hose kinks or need for precise cleaning to avoid residue: "Follow manual for disassembly—works flawlessly otherwise." Some note it's not battery-powered, limiting outdoor use. Recommendation: Highly recommended for home and travel respiratory relief; consult a doctor for medication compatibility. Addresses key issues like noise and portability better than competitors.
Faqs
How do I set up my beurer Nebuliser IH 58 for the first time?
What should I do if the beurer Nebuliser IH 58 produces little or no mist?
Can I use all prescription inhalation medications with the beurer Nebuliser IH 58?
How can I reduce treatment time and optimize performance on the beurer Nebuliser IH 58?
What maintenance does the beurer Nebuliser IH 58 require after each use and long-term?
Why does my beurer Nebuliser IH 58 make noise or shut off unexpectedly during treatment?
Are beurer Nebuliser IH 58 accessories interchangeable with other Beurer models or third-party parts?
How do I clean and disinfect the beurer Nebuliser IH 58 to prevent common problems?
More beurer manuals