Omron Electro Therapy Pain Relief PM3030 User Guide
Content
Introduction
The Omron Electro Therapy Pain Relief PM3030 is a compact and portable device designed to provide effective relief from various types of pain through TENS (Transcutaneous Electrical Nerve Stimulation) technology. The Omron PM3030 is priced at $79.99. The Omron PM3030 electroTHERAPY pain relief solution is intended for the relief of pain associated with sore or aching muscles of the lower back, arms, or legs due to strain from exercise or normal household and work activities. It should be applied to normal, healthy, dry, clean skin of adult patients.
Box Contains
This box contains the following components:
- Unit
- Electrode Cords
- 2 Self-Adhesive Pads
- Plastic Pad Holder
- Two AAA Batteries
- Instruction Manual
- Quick Start Guide with Pad Placement Guide
Specifications
Product Name | electroTHERAPY pain relief |
Model # | PM3030 (HV-F158-Z) |
Power Source | DC3V (2 AAA alkaline batteries or 2 AAA manganese batteries) |
Battery Life | New batteries will last for approx. 3 months (whenused for 15 minutes a day, Back Mode, max. intensity). |
Output Frequency | Approx. 1–100Hz |
Power Control | 5 intensity levels |
Operating Temperature, Humidity | +50°F to +104°F (+10°Cto +40°C), 30 to 85% RH |
Storage Temperature, Humidity, Air Pressure | –4°F to +140°F (–20°Cto +60°C), 10 to 95% RH, 700 - 1060 hPa |
Weight | Approx. 60g (incl.batteries) |
Outer Dimension | Width 55mmx Height 95mmx Depth 18mm |
Description
The Omron Electro Therapy Pain Relief PM3030 utilizes Transcutaneous Electrical Nerve Stimulation (TENS) technology to deliver electrical impulses to the body, targeting pain areas and promoting relief. The device comes with interchangeable electrode pads that can be placed on different parts of the body, allowing users to target specific areas of discomfort.
The PM3030 features several pre-set programs tailored for different types of pain, including lower back pain, joint pain, and muscle soreness. Users can adjust the intensity of the electrical impulses to their comfort level, ensuring a personalized therapy experience.
IMPORTANT SAFETY PRECAUTIONS AND WARNINGS
It is important that you read all the warnings and precautions included in this instruction manual because they are intended to keep you safe, prevent injury and avoid a situation that could result in damage to the device.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
DANGER: This unit must not be used in combination with the following medical devices:
- Internally transplanted electronic medical devices, such as a pacemaker.
- Electronic life support equipment, such as respirators. Electronic medical devices attached to the body, such as electrocardiographs.
- Using this unit with other electronic medical devices may cause erroneous operation of those devices.
How Electrotherapy for pain relief works
What is it?
The electroTHERAPY for pain relief device is a 3-program, portable device designed for adults only. It is designed to reduce and relieve muscle and joint pain, stiffness and numbness in the arms, legs and foot by applying electrical nerve stimulation to the surface of the skin near the site of the pain. It can be successfully used in conjunction with any other pain treatment or medication. This type of therapy, called Transcutaneous Electrical Nerve Stimulator (TENS), has been used for over 30 years by medical professionals such as physical therapists and chiropractors.
How does it work?
Scientific theory suggests that electrical stimulation therapy may work in several ways:
- The gentle electrical pulses move through the skin to nearby nerves to block or shut out the pain message from ever reaching the brain from the source of the pain.
- The gentle electrical pulses increase the production of the body’s natural pain killer, such as endorphins.
- Furthermore, it is thought that the electrical stimulation improves blood circulation as well. Muscles contract and relax with the flow of the electrical stimulation. With repeated contracting and relaxing, the blood flows in and out and the blood circulation is improved.
KNOW YOUR UNIT
PACKAGE CONTENTS
FEATURES
- Three pre-set programs (Arm, Lower Back, Leg/Foot).
- Five intensity levels of therapy, 1 low intensity to 5 high intensity.
- 3. Pair of pads (durable, re-usable, washable, up to 150 uses).
(Do not use with non-manufacturer’s pads or electrode cord).
BUTTONS AND THEIR FUNCTIONS
SIMPLE ASSEMBLY STEPS
- STEP 1 – INSERT BATTERIES
- Remove the battery cover on the back.
- Insert batteries. Make sure the signs correspond when inserting batteries.
Reinstall the battery cover.
NOTES:
- During battery replacement, replace both batteries with new ones.
- Dispose of the used batteries according to the local regulations.
STEP 2 – ATTACH ELECTRODE CORD TO THE UNIT
Attach the clip of the electrode cord to the top and plug into the main unit.STEP 3 – ATTACH PADS TO THE ELECTRODE CORD
For the first time, take the pads out of the sealed package and remove the clear plastic film from the back of the pad. Discard the plastic film backing as well as the clear packaging.
(In-between uses, turn unit off and keep electrodes connected to pads. Place pads onto sides of plastic holder and wrap cord around holder and store in a dry, cool location).STEP 4 – SNAP EITHER ELECTRODE CORD TO EACH OF THE PADS
EASY STEPS TO GET STARTED
(USE FOR A MAXIMUM OF 30 MINUTES)
STEP 1 – PAD PLACEMENT
Place pads on clean, dry and healthy skin near the area with pain at least 1" apart, and do not let them touch. OK to place near or surrounding the pain. Make sure there is a linear path between the two pads. (See Pad Placement Guide insert or the following illustrations). Before starting your therapy, rate your pain from 1 low to 10 high. This mental check gives you a basis you can compare to once the session is complete.
LOWER BACK
Attach both pads on the lower back with the backbone in the center. Do not place on the backbone or spine.
SCIATIC
Attach one pad below and above the region in pain, both on same side (NOT on spine).DELTOID
Attach one pad in front and one in back of the muscle.
UPPER ARM
Attach both pads on either side of the region where you feel pain.
ELBOW
Attach both pads on either side of the joint with the pain.
HIP & THIGH
Attach both pads on either side of the area with pain.KNEE
Attach both pads above the knee or above and below the joint with pain.
CALF
Attach both pads on the calf/leg where you feel pain. (Do not place electrode pads simultaneously to the calves of both legs.)
ANKLE/FOOT
Attach pads per the illustration, on the left for pain on the outside of your ankle/foot. Attach the pads per the illustration on the right for pain on the inside of your ankle/foot.STEP 2 – SELECT 1 OF 3 PROGRAMS
Push “ON” and the default program “blinks” (device defaults to the last program at the lowest intensity level).
Personalize your therapy by pushing the orange circle button to a pre-set program (1. Arm 2. Lower Back 3. Leg/Foot).How do you switch programs?
Each time you push the orange circle button, it switches to the next program at the lowest intensity level. Depending on the program, you will feel a gentle combination of tapping, kneading or pulsing sensations that vary in pulse speed.Therapies designedfor Upper & Lower Arm, Elbow
Lower Back
Leg, Knee,Foot, Hip & Thigh
Potential conditions Swelling, stiffness, sore or achy, muscle or nerve pain
Stiffness, soreness, muscle spasm, nerve pain
Swelling, fatigue, chilling feeling, sore or achy
What does the therapydeliver? Series of low rate tapping, tingling and pulsing sensations.
Series of tingling sensations, followed by tapping. With higher intensity, you may feel kneading or massage sensations.
Series of tappingsensations.
How long does the therapy last? Turns off automatically at 15 minutes
How do I personalize the therapy? You set the program. You pick the intensity (level1 to level 5)
How longshould I use it? How often? Total 30 minutes per session. 3 times/day at most.
When should you stop using it? If pain is reduced or stopped. If it’s uncomfortable. If there’s an adverse reaction. If the condition worsens. If the condition continues for 5+ days.
How to select the right program
Select the program that feels right for your unique pain. The programs are interchangeable and may be used for more than one body part.STEP 3 – SELECT THE CORRECT INTENSITY LEVEL (1 LOW – 5 HIGH)
Start at the lowest intensity level and slowly increase it by pushing the green “UP” arrow button. You should feel a gentle pulsing sensation.
How do I pick the right intensity level for my pain?
Each time you push the green “up” or “down” arrow, it moves to another level. If the stimulation sensation becomes weaker or disappears, increase the intensity until it is restored. But, if the sensation is at all uncomfortable, press the down arrow to decrease the intensit- Press ▲ for higher intensity.
- Press ▼ for lower intensity.
What intensity level is my unit on?
The program’s blinking light indicates the level you have selected.
For example, 2 blinks means you are at level 2, 3 blinks means level 3 and so on.
The number of blinks corresponds to the selected intensity level.
HOW TO CONTROL AND REDUCE YOUR PAIN
When should the device be used?
Use as soon as your pain begins. Start with one session (unit automatically turns off at 15 minutes). Turn off with pads still on and RATE YOUR PAIN again (1 low to 10 high).
Get to your pain early
If you get to your pain early, it may prevent the pain from becoming worse, or even chronic. It’s better for you to get it under control sooner so that it does not reach a high pain threshold where it limits your daily activities.
How long should you use it?
Start with one 15 minute session. Always turn unit off with pads still on. Rate your pain to check your progress, 1 low to 10 high. Stop therapy session if pain has reduced or stopped. Press “On” button to continue therapy for another 15 minute session.
1 Session | Max Minutes/Session | Max Times/Day |
---|---|---|
15 minutes | 30 minutes | 3 times per day |
Automatic shut-off | Two sessions |
(NOTE: Long-time treatment and strong stimulation may cause muscular fatigue and may generate adverse effects.)
When to stop using the device?
- If you experienced an adverse reaction (skin irritation/ redness/.burns, headache or other painful sensation, or if you feel any unusual discomfort).
- If your pain does not improve, becomes seriously chronic and severe, or continues for more than five days.
What type of pain is it best for?
This therapy works best on acute pain because it is localized. Acute pain is pain in one area for less than 3 months. If you have chronic pain, you may have pain in more than one area and for longer than 6 months. Chronic pain may be compounded by other issues that this device cannot address.
Yet remember, this device does not cure your pain or the original cause of the pain. It provides temporary relief or reduction of pain so that you can control your life and activities better.
Setup Guide
To set up and operate the Omron Electro Therapy Pain Relief PM3030, follow these steps:
- Charge the device according to the manufacturer's instructions.
- Choose the appropriate electrode pads based on the area of pain.
- Apply the electrode pads to the skin, following the guidelines provided.
- Turn on the device and select the pre-set program or adjust settings manually.
- Adjust the intensity level as needed during the therapy session.
CLEANING AND STORAGE
The unit is designed for repeated use over time. The pads will last up to 150 uses, or 5 months (based on use 1/day). Here are important cleaning and storage instructions:
Cleaning the pads
- Turn the power off and remove the electrode cord from the pads.
- Wash the pads when the adhesive surface becomes dirty and/or the pads are difficult to attach.
Wash the pad softly with your fingertips under slow running cold water for several seconds (do not use a sponge/cloth/sharp object like a nail on adhesive side, do not use detergents, chemicals or soap). - Pads can be washed after 15 uses, approximately ten times for up to 150 uses (do not wash the pads too long or too frequently).
- Dry the pads and let the adhesive surface air-dry completely (do not wipe with a tissue paper or cloth).
- Pads are replaceable and can be purchased when needed by calling 1-800-634-4350 or go to www.omronhealthcare.com. The life of pads may vary by the frequency of washing, skin condition, and storage state.
When should you replace your pads?
If the pad no longer sticks to your skin or if more than 25% of the pad’s surface is not in contact with your skin.
Cleaning the unit
- Turn unit off and disconnect the electrode cords from the pads.
- Clean with a lightly moistened cloth (or a cloth soaked in a neutral cleaning solution) and wipe gently.
- Do not use chemicals (like thinner, benzene).
- Do not let water get into the internal area.
Storing the pads
Turn the unit off and remove the cord plug from the jack.
- Remove the pads from your body.
- Leave the electrode cords connected to the pads and place the pads on the pad holder (one on each side).
Wrap the electrode cords around the pad holder.
Storing the unit and pads
- Place the unit, pads with electrode cords on pad holder, Pad Placement Guide and Instruction Manual inside the original box.
- Do not keep in areas subject to direct sunlight, high or low temperatures, humid areas, near to fire, vibration, or shock. Store in a cool, dry place, 5º ~ 40ºC (4º - 104ºF), 30% - 40% relative humidity.
- Do not keep at places that can be easily reached by children.
- When not in use for a long period, remove the batteries before storage, to avoid liquid discharge from batteries.
Omron Electro Therapy Pain Relief PM3030 Troubleshooting
If this happens... | Possible causes... | Try this solution... |
The intensity is not felt. Very weak intensity level. | Are both pads attached to the body? | Attach both to the body. |
Have you removed the transparent film from the pad? | Peel off film on the adhesive surface of pads. | |
Are the pads stacked together or do pads overlap? | Do not stack pads together or overlappads. | |
Is the cord properly connected to the unit? | Connect cord correctly into the jack. | |
Is the intensity setting getting weak? | Press the ▲ up button. | |
Are the batteries weak? | Replace batteries. |
The skin turns red or | Is the adhesive | Wash adhesive |
the skin feels irritated. | surface of pads dirty | surface of pads softly |
| or dry? | with your fingertips |
|
| for about 3 seconds |
|
| under slow running |
|
| water. |
| Is therapy time | Use less than |
| too long? | 15 minutes. |
| Are the 2 pads | Attach 2 of them |
| attached properly to | properly. |
| the body? |
|
| Is the pad surface | Replace pad. |
| worn out? |
|
No power source. | Are the polarities of battery (+ and -) aligned in the wrong direction? OR batteries are depleted. | Insert batteries in correct alignment, OR replace batteries. |
Power cut off during use. | Are the batteries weak? | Replace batteries. |
Is the cord broken? | Replace cord. |
It is difficult to attach the pad to the skin. | Have you removed the transparent film from the pad? | Peel off film on the adhesive surface of pads. |
Was the pad appliedimmediately after washing? | Sufficiently dry the pad. | |
Is the adhesive surface of the pad damaged? | Replace the pad. |
Adhesivesurface of pad is not sticky. | Are you using pad during perspiring? | Use when not perspiring. |
Have pads been washed too long and/ or too frequently? | Leave the pad in freezer for overnight. | |
Were the pads stored under high temperature, high humidity, or direct sunshine? | Replace the pad. | |
If the above measures are not effective, contact OMRON at www.omronhealthcare.com |
WARRANTY
Your electroTHERAPY for pain relief unit and electrode cords are warranted for 1 year and the pads are warranted for 30 days. They are guaranteed to be free from defects in materials and workmanship if used in accordance with the instructions provided. The above warranties extend only to the original retail purchaser. We will, at our option, repair or replace without charge any device covered by the above warranties. Repair or replacement is our only responsibility and your only remedy under the above warranties.
Pros & Cons
Pros
- Effective in providing quick pain relief
- Easy to use and operate
- Portable and compact design
- Adjustable intensity levels for personalized therapy
- Affordable compared to other pain relief methods
Cons
- Limited battery life if used extensively
- May cause skin irritation in some users
- Not suitable for all types of pain or medical conditions
- Requires frequent replacement of electrode pads
Customer Reviews
The Omron Electro Therapy Pain Relief PM3030 has received positive reviews from many users who have experienced significant pain relief.
Common Complaints
Here are some common praises and complaints
Users appreciate the ease of use and the effectiveness of the device in relieving chronic pain. However, some users have reported issues with skin irritation and the need for frequent electrode pad replacements.
Faqs
What is the primary function of the Pain Relief PM3030?
How do I set up and use the Omron Electro Therapy?
How often should I replace the electrode pads?
Is the Omron Electro Therapy Pain safe for pregnant women?
How long does a typical therapy session last with the Therapy Pain Relief?
Can children use the Pain Relief?
What are some common side effects of using the Pain Relief PM3030?
Is there a warranty available for the Therapy?
Leave a Comment