The **Beurer Nebuliser IH 26** is a high-performance compressed-air nebuliser designed for effective treatment of upper and lower respiratory tract issues, including colds, asthma, and other respiratory diseases. Utilizing advanced AC compressed-air technology, this medical device delivers a high proportion of respirable particles with an impressive nebulisation performance of approximately 0.3 ml/min, ensuring very short inhalation times for quick relief. Ideal for home use, the **Beurer Nebuliser IH 26** comes with an extensive year pack, including a nebuliser bottle, mouthpiece, nosepiece, adult and child masks, nasal douche, compressed air tube, filters, and a practical storage bag, making it a complete solution for respiratory care.

Key benefits include easy single-button operation, hygienic reusability after proper cleaning and disinfection, and an integrated LED indicator (blue for ready status) for user-friendly monitoring. The **Beurer nebuliser IH 26** targets families, individuals with chronic respiratory conditions, and those seeking fast, targeted inhalation therapy. Its working pressure of 0.8–1.45 bar supports deep penetration into airways, outperforming traditional steam baths by producing smaller, more effective particles.

Priced in the estimated range of $80–$120 depending on retailers, the **Beurer Nebuliser IH 26** is widely available online and in pharmacies, offering excellent value for a durable device with a 5-year guarantee. Whether managing seasonal colds or ongoing asthma, this nebuliser enhances well-being with reliable, medical-grade performance.

DESCRIPTION OF THE DEVICE AND ACCESSORIES

  1. Carrying handle
  2. On/Off switch (back)
  3. Mains connector cable
  4. Hose connector
  5. Filter cap with filter
  6. Holder for atomiser

Overview of Atomiser and Accessories

  1. Nasal douche
  2. Compressed air hose
  3. Atomiser
  4. Atomiser insert
  5. Valve
  6. Medicine container
  7. Mouthpiece
  8. Adult mask
  9. Child mask
  10. Nosepiece with comfort attachment

    beurer_nebuliser_ih-26.png

Technical Specifications

  • Model: IH 26
  • Type: IH 25/2
  • Dimensions (W x H x D): 166 x 141 x 149 mm
  • Weight: 1.4 kg
  • Operating Pressure: Approx. 0.5 to 1.45 bar
  • Atomiser Filling Volume:
    • Maximum: 8 ml
    • Minimum: 2 ml
  • Medication Flow Rate: Approx. 0.35 ml/min
  • Sound Pressure: Approx. 52 dBA
  • Mains Connection:
    • 230 V AC, 50 Hz, 230 VA
    • UK: 240 V AC, 50 Hz, 240 VA
  • Expected Service Life: Information on the service life of the product can be found on the manufacturer's homepage.

Operating Conditions

  • Temperature: +10°C to +40°C
  • Relative Humidity: 10% to 95%
  • Ambient Pressure: 700 to 1060 hPa

Storage and Transportation Conditions

  • Temperature: -25°C to +70°C
  • Relative Humidity: 10% to 95%

Aerosol Values According to EN ISO 27427:2023

Based on adult breathing patterns with sodium fluoride (NaF):

  1. Aerosol Delivery: 0.11 ml
  2. Aerosol Delivery Rate: 0.07 ml/min
  3. Fill Volume Dispensed per Minute: 3.27%
  4. Residual Volume: 1.68 ml
  5. Particle Size (MMAD): 3.07 µm
  6. GSD (Geometrical Standard Deviation): 2.03
  7. RF (Respirable Fraction, <5 µm): 75%
  8. Large Particle Range (>5 µm): 25%
  9. Medium Particle Range (2 to 5 µm): 47.8%
  10. Small Particle Range (<2 µm): 27.2%

INTENDED USE

Purpose

Nebulisers (including compressor, ultrasonic and mesh nebulisers) are medical devices for the nebulisation of liquids and liquid medication (aerosols). This device produces aerosols by combining compressed air and liquid medication. The aerosol treatment is suitable for treating the upper and lower airways. By nebulising and inhaling the medication prescribed or recommended by your doctor, you can prevent diseases affecting the airways or, if you develop such an illness, alleviate symptoms and speed up your recovery.

Target Group

The nebuliser is only intended for medical care in a home environment. The nebuliser is not intended for healthcare in professional environments. The nebuliser can be used on anyone over 2 years of age under supervision; it can be used for self-treatment by anyone over 12 years of age. When using the nebuliser with the baby mask, the device can be used under supervision on those aged 6 months and over. The shape of the person's face determines whether or not the device can be used under supervision. As such, it may be possible to use the device under supervision on someone who is younger, or conversely, it may not be possible to use the device until they are older. When using a mask to inhale, take care to ensure the mask fits well and the eyes are unobstructed.

Clinical Benefits

Inhalation is the most effective way to administer medication for many respiratory system conditions.

The benefits are:

  • The medication is transported directly to the target organs.
  • The local bioavailability of the medication is significantly increased.
  • Systemic diffusion is reduced substantially.
  • Lower doses of medication may be required.
  • Quick and effective therapeutic effect.
  • Side effects may be reduced compared to systemic administration.
  • Humidifying of the airways.
  • Loosening and making bronchial secretions more liquid.
  • Relieving bronchospasms (spasmolysis).
  • Relieving swollen and inflamed bronchial mucosa.
  • Helping to cough up secretions.
  • Supporting the treatment of respiratory conditions affecting the upper and lower airways.

Indications

The nebuliser can be used for diseases of the upper and/or lower airways.

Examples of upper respiratory system diseases include:

  • Rhinitis.
  • Allergic rhinitis.
  • Sinusitis.
  • Pharyngitis.
  • Laryngitis.

Examples of lower respiratory system diseases include:

  • Bronchial asthma.
  • Bronchitis.
  • COPD (chronic obstructive pulmonary disease).
  • Bronchiectasis.
  • Acute tracheobronchitis.
  • Cystic fibrosis.
  • Pneumonia.

Contraindications

  • The atomiser is not intended for the treatment of life-threatening conditions.
  • This device must not be used by children under the age of 12 or by people with reduced physical, sensory (e.g. reduced pain sensitivity) or mental abilities, or a lack of experience or knowledge, unless they are supervised or have been instructed on how to use the device safely and are fully aware of the associated risks.
  • Do not use the device on persons who are ventilated and/or unconscious.
  • Check the medication instruction leaflet for any contraindications associated with the usual systems for aerosol treatment.
  • If the device does not work properly, or if you feel unwell or experience pain, stop using it immediately.

WARNINGS AND SAFETY NOTES

Warning

  • The atomiser has no significant influence on the efficacy and safety of the medication administered and is not intended for the treatment of life-threatening conditions.
  • If the device malfunctions, please refer to the "What if there are problems" section.
  • The device is not a substitute for medical consultation and treatment. Always consult your doctor first in the event of pain or illness.
  • If you have health concerns of any kind, consult your GP.
  • If the liquid you wish to use is not compatible with PP, silicone and PVC, do not use this liquid with the nebuliser. If the information provided with the liquid does not indicate whether it is compatible with these materials, please contact the liquid manufacturer. Sodium fluoride is an example of a compatible liquid.

Fuse

The device is fitted with an overcurrent protection device. This may only be replaced by authorised specialist personnel.

General Notes

Important

  • The device is suitable only:
    • For use on people.
    • For the purpose for which it is designed (aerosol inhalation) and in the manner specified in these instructions for use.
  • Any form of improper use can be dangerous.
  • In the event of an acute emergency, providing first aid must take top priority.
  • Apart from the medication, only use distilled water or a saline solution. Other liquids may cause a fault in the nebuliser or atomiser.

Before Initial Use

Important

  • Remove all packaging material before using the device.
  • Protect the device against dust, dirt and humidity, and never cover the device while it is in use.
  • Do not operate the device in a very dusty area.
  • Switch the device off immediately if it is faulty or not working properly.
  • The manufacturer is not liable for damage resulting from improper or incorrect use.
  • This device is not intended for commercial or clinical use; it is designed exclusively for self-treatment in a private home.

Repairs

  • Under no circumstances should you open or repair the device yourself; otherwise, proper functionality can no longer be guaranteed. Failure to comply with this instruction will void the warranty.
  • The device is maintenance-free.
  • For repairs, please contact Customer Services or an authorised retailer.

INITIAL USE

Positioning the Device

  • Take the device out of the packaging.
  • Place the device on a flat surface.
  • Make sure that the vents are free from obstructions.

Before Using the Device for the First Time

Clean and disinfect the atomiser and accessories before using them for the first time. See "Cleaning and disinfection".

  • Connect the compressed air hose (8) to the bottom of the medication container (12).
  • Connect the other end of the compressed air hose (8) to the nebuliser hose connection (4) by turning it slightly.

Power Supply

The device must only be connected to the mains voltage that is specified on the type plate.

  • Insert the mains plug of the mains connector cable (3) into a suitable socket.
  • To connect to the mains, fully insert the mains plug into the socket.
  • Ensure that there is a mains socket close to the setup area.
  • Arrange the mains connector cable so that no one will trip over it.
  • To disconnect the nebuliser from the mains after inhalation, first switch off the device and then pull the mains plug out of the socket.

OPERATION

Important

  • For hygiene reasons, it is essential to clean the atomiser (9) and the accessories after each treatment and to disinfect them after the last treatment of the day.
  • The accessories may be used only by one person; use by several people is not recommended.
  • If the therapy involves inhaling several different medications one after the other, please be aware that the atomiser (9) must be rinsed under warm tap water following every usage. See "Cleaning and disinfection".
  • Please observe the notes on changing the filter in these instructions for use.
  • Check that the hose connectors are firmly attached to the nebuliser (4) and the atomiser (9) before each use of the device.
  • Before use, check that the device is working correctly by briefly switching on the nebuliser (together with the connected atomiser, but without medication). If air comes out of the atomiser (9), the device is working.

Installing the Atomiser Insert

  • Open the atomiser (9) by twisting the top anticlockwise against the medication container (12). Place the atomiser insert (10) into the medication container (12).
  • Ensure that the cone for administering medication fits well on the cone for the air duct inside the atomiser (9).

Filling the Atomiser

  • Fill with an isotonic saline solution or pour the medication directly into the medication container (12). Avoid overfilling. The maximum recommended filling quantity is 8 ml.
  • Use medication only as instructed by your doctor and ask about the appropriate inhalation period and quantity for you.
  • If the prescribed quantity of medication is less than 2 ml, top this up to at least 4 ml with isotonic saline solution. Dilution is also necessary with viscous medications. Here too, please observe the instructions of your doctor.

Closing the Atomiser

  • Close the atomiser (9) by twisting the top clockwise against the medication container (12). Ensure that the connection is correct.

Inserting the Valve

  • Press the blue valve (11) into the opening intended for this purpose on the upper side of the atomiser (9). The valve system ensures better delivery of the medication to the lungs. Only use the valve (11) with the mouthpiece (13), never with the masks (14, 15) or the nosepiece (16).

Connecting Accessories to the Atomiser

  • Connect the atomiser (9) to the desired accessory: mouthpiece (13), adult mask (14), children's mask (15) or nosepiece (16).
  • In addition to the accompanying adult mask (14) and children's mask (15) (from 2 years of age), you also have the option of using a baby mask (from ages 0–3 years) with your nebuliser.

The baby mask is not included in delivery with the IH 26. You can find an overview of all replacement items in the chapter "Accessories and/or replacement parts". The most effective form of nebulisation is by using the mouthpiece. Nebulisation using a mask is only recommended if it is not possible to use a mouthpiece (e.g. for children who are not yet able to inhale medication using a mouthpiece). If you are using the adult mask (14), you can secure it to your head with the adult mask strap. There is also a strap for the children's mask (15). When using a mask to inhale, take care to ensure the mask fits well and the eyes are unobstructed.

  • Before the treatment, pull the atomiser upwards out of the holder (6).
  • Start the nebuliser using the On/Off switch (2).
  • Spray mist pouring out of the atomiser indicates that the device is operating correctly.

Treatment

  • When inhaling, sit upright and relaxed at a table and not in an armchair to avoid compressing the airways and therefore impairing the effectiveness of the treatment.
  • Breathe in the atomised medication deeply.

Important

The device is not suitable for continuous operation; after 30 minutes of operation, it must be switched off for 30 minutes. During the treatment, hold the atomiser straight (vertically), otherwise, atomisation will not work correctly, and proper functionality cannot be guaranteed.

Stopping Inhalation

Once the mist is only coming out in an irregular flow or if the sound changes when inhaling, you can stop the treatment.

  • Switch off the nebuliser after treatment using the On/Off switch (2) and disconnect it from the mains.
  • Place the atomiser (9) back in its holder (6) after the treatment.

Nasal Douche

  1. Cover
  2. Collection container for nasal secretions
  3. Saline container
  4. Cover hole (for starting the application)

You can use the nasal douche to clean your nasal cavities. The nasal douche creates a fine jet of liquid for treating respiratory tract problems or for moistening the nasal mucous membranes.

Warning: Do not use the nasal douche in combination with other medication or essential oils.

Important

  • The nasal douche should only be used with isotonic saline solutions.
  • Replace the nasal douche after one year.

The maximum volume of the nasal douche is 10 ml. If you are unsure about the correct dilution of the saline solution, please consult your doctor.

Using the Nasal Douche

To use the nasal douche correctly, proceed as follows:

  1. Twist the cover (18) 90° anticlockwise and remove it in an upward direction.
  2. Lift the collection container (19) out.
  3. Fill the saline container (20) with saline solution.
  4. Place the collection container (19) into the saline container (20).
  5. Place the cover (18) on the saline container (20). Twist the cover (18) in a clockwise direction until it clicks firmly into place.
  6. Connect the compressed air hose (8) to the saline container (20) from below.
  7. Position the cover (18) carefully inside one of your nostrils. Breathe through the nose.
  8. Press the On/Off switch (2) on the back of the nebuliser. To start the application, place one finger over the cover hole (21) on the container.
  9. To pause or stop the application, take your finger off the cover hole (21) on the saline container (20).
  10. Once your nose feels clear again, you can stop the application. The application should be stopped at the latest once the maximum filling quantity has been used.

During the application, breathe slowly and evenly through the nose. Tilt your head slightly in the opposite direction to the nostril being treated so that the saline solution can flow deep into the nose.

CHANGING THE FILTER

In normal operating conditions, the air filter must be replaced after approximately 200 operating hours or one year. Please check the air filter regularly (after 10–12 nebulisation procedures). Replace the used filter if it is very dirty or clogged. If the filter has become damp, it must also be exchanged for a new filter.

Important

  • Do not attempt to clean the used filter and reuse it.
  • Only use the manufacturer's original filter, otherwise, your nebuliser may become damaged and sufficiently effective treatment cannot be guaranteed.
  • Do not repair or maintain the air filter while it is in use.
  • Never operate the device without a filter.

To replace the filter, proceed as follows:

Important

  1. First switch the device off and disconnect it from the mains.
  2. Allow the device to cool down.
  3. Remove the filter cap (5) upwards. If the filter remains in the device after the cap has been removed, take the filter out of the device, e.g. with tweezers or a similar tool.
  4. Reinsert the filter cap (5) with a new filter.
  5. Ensure that it is securely in place.

CLEANING AND MAINTENANCE

Atomiser and Atomiser Set

Warning

Adhere to the following hygiene instructions to avoid health risks.

  • The atomiser (9) and the rest of the atomiser set are intended for multiple use. Please note that different areas of application involve different requirements in terms of cleaning and hygienic preparation.

Do not clean the atomiser or the atomiser set mechanically using a brush or similar device, as this could cause irreparable damage and the best treatment results can no longer be guaranteed.

  • Please consult your doctor about the additional requirements in terms of hygienic preparation (hand care, handling of medication/inhalation solutions) for high-risk groups (e.g. patients with cystic fibrosis).
  • Ensure thorough drying after each cleaning and disinfection process. Residual moisture or wetness can represent an increased risk of bacterial growth.

Preparation

  • Immediately after each treatment, all parts of the atomiser (9) and the used accessories must be cleaned of residual medication and contamination.
  • To do this, dismantle the atomiser (9) and the nasal douche (7) into their individual parts.
  • Remove the mouthpiece (13), the mask (14, 15) or the nosepiece (16) from the atomiser.
  • Disassemble the nosepiece if you have used it with the comfort attachment.
  • Dismantle the atomiser by twisting the top anticlockwise against the medication container (12).
  • Remove the atomiser insert (10) from the medication container (12).
  • Remove the valve (11) by pulling it out of the atomiser (9).
  • Reassembly is carried out in reverse order.

Condensation and Hose Care

Condensation may form in the hose depending on the ambient conditions. It is essential to remove the moisture to prevent bacterial growth and ensure proper treatment. To do so, proceed as follows:

  • Disconnect the hose (8) from the atomiser (9).
  • The hose must remain connected to the nebuliser (4).
  • Operate the nebuliser until the moisture is removed by the air passing through.
  • In the event of heavy contamination, replace the hose.

Disinfection

Please carefully observe the points below when disinfecting your atomiser and the atomiser set. We recommend disinfecting the individual parts on a daily basis after the last usage as a minimum measure.

  • First, clean the atomiser and atomiser set as described in the "Cleaning" section.
  • Place the disassembled atomiser (9), nasal douche (7), mouthpiece (13), and the disassembled nosepiece (16) in boiling water for 5 minutes. Contact between the parts and the hot base of the pan should be avoided.
  • For disinfection, immerse the masks and the compressed air hose for 15 minutes in a 2% sodium hypochlorite (NaOCl) solution (i.e., a solution with Amuchina disinfectant or a 2% sodium hypochlorite solution prepared by your pharmacist). Afterwards, rinse all parts thoroughly with tap water to fully remove any possible residue of the disinfectant solution.

Important

  • Do not boil or autoclave the compressed air hose.
  • Put the parts together again when they are completely dry and place them in a dry, sealed container.
  • Ensure that the parts are completely dried after cleaning; otherwise, the risk of bacterial growth is increased.

Drying

Place the individual parts on a clean, dry and absorbent surface and leave them to dry completely (at least 4 hours).

Durability of Materials

  • As with any plastic parts, atomisers and the rest of the atomiser set are affected by a certain amount of wear and tear when used and hygienically prepared frequently. Over time, this can lead to a change in the aerosol, which can hurt the efficiency of the treatment. We therefore advise you to replace the atomiser and the atomiser set no later than one year if the parts are not disinfected more than 360 times a year. Frequent disinfection shortens the service life of the parts.
  • The following point should be observed when selecting the cleaning product or disinfectant: Only use a mild cleaning product or disinfectant in the concentration and volume prescribed by the manufacturer.

Storage

  • Do not store in damp conditions (such as in a bathroom) and do not transport with any damp items.
  • When storing and transporting, protect from prolonged direct sunlight.
  • Store the device in a dry place, ideally in the original packaging.

Troubleshooting the Beurer Nebuliser IH 26: Common Issues and Fixes

Encountering problems with your **Beurer Nebuliser IH 26**? Start by checking the LED indicator: blue means ready; no light may indicate power issues. Common issues include no mist output, often due to a clogged nebuliser or empty filter—replace the filter from the year pack and ensure the device functions by running it briefly without medication to confirm airflow.

  • No power: Verify 230V/50Hz mains connection; check fuse and cable integrity. Operate only with compatible Beurer accessories to avoid inefficiency.
  • Weak nebulisation: Clean removable parts with disinfectant; ensure operating pressure (0.8–1.45 bar). Short inhalation time should resume after hygiene maintenance.
  • Overheating: Follow 30 ON/30 OFF cycle to prevent strain; avoid spray rooms and heat sources.
  • Nasal douche leaks: Check connections; disinfect after each use for hygiene.

Prevent issues by replacing all accessories and filters per the year pack schedule, surface-disinfecting the device, and storing in the included bag. IP21 rating protects against drips but not immersion—keep dry. Beurer offers a 5-year guarantee; contact support at Beurer's global service hotline (check beurer.com for local numbers) or email via their website for warranty claims and repairs.

Pros and Cons of the Beurer Nebuliser IH 26

Pros

  • High nebulisation performance: 0.3 ml/min rate ensures short sessions, ideal for quick asthma or cold relief.
  • Comprehensive accessories: Includes nasal douche, masks for adults/children, and a year pack for long-term use.
  • User-friendly design: Single-button operation, LED status light, and easy cleaning promote hygienic, daily home therapy.
  • Durability and value: 5-year guarantee, 1.4 kg compact build (166x141x148 mm), superior to basic steam inhalers for deep airway penetration.

Cons

  • Mains-powered only: Requires a 230V outlet, less portable than battery models
  • Noise from compressor: Compressed-air tech can be audible during 30-minute cycles.
  • Maintenance intensive: Needs regular filter swaps and disinfection, though the year pack helps.

Overall, the **Beurer Nebuliser IH 26** offers strong value for money at its price point, excelling over cheaper alternatives in performance and accessories, though portability lags behind ultrasonic nebulisers.

Customer Reviews and Feedback on Beurer Nebuliser IH 26

The **Beurer Nebuliser IH 26** earns a perfect 5.0-star rating on the official site, with users praising its fast, effective nebulisation for colds and asthma. Common praises include the nasal douche for congestion relief and short treatment times: "Breathe freely in minutes—game-changer for family respiratory care!" notes one reviewer.

Testimonials highlight ease of use: "Simple setup, hygienic parts, and powerful mist reach deep lungs" (5 stars). Families appreciate child masks and the year pack's convenience. Frequent recommendations for home use, especially vs. clinic visits.

Minor complaints involve compressor noise, addressed by quieter operation tips in manuals. No widespread issues reported; most confirm reliability post-cleaning. Highly recommended for **Beurer nebuliser IH 26** buyers seeking proven compressed-air therapy.

PDF

Faqs

How do I set up the beurer Nebuliser IH 26 for the first time?

Unpack all parts and read the user manual before first use; place the compact IH 26 on a stable surface and connect the power cable to a 230 V outlet. Fit the compressed air tube between the compressor outlet and the nebuliser bottle, insert the nebuliser insert and medication cup, then attach the mouthpiece or mask. Perform a short test run (without medication) to confirm airflow and aerosol output before administering medicine.

What should I do if my beurer Nebuliser IH 26 produces little or no mist?

Check that the device is powered and the compressor runs; ensure the nebuliser bottle and insert are assembled correctly and not clogged. Replace or clean the filter if blocked, inspect the compressed air tube for kinks, and confirm the medication volume meets minimum fill requirements. If moisture has accumulated in the tubing, run the unit briefly without medication to dry it. Contact support if problems persist.

Can I use my beurer Nebuliser IH 26 with all inhalation medicines and saline solutions?

Use only nebuliser-approved liquids and medications prescribed for compressed-air (jet) nebulisers; normal saline (0.9% NaCl) is commonly safe. Always check the medication leaflet for nebuliser compatibility and concentration. Do not use oily or viscous substances, undiluted essential oils, or medications not intended for aerosol delivery to avoid clogging and unsafe dosing.

How do I optimise performance and shorten inhalation time with the beurer Nebuliser IH 26?

Use the correct nebuliser insert and a well-fitting adult or child mask/mouthpiece to reduce aerosol loss. Keep the device upright during treatment and maintain the recommended operating pressure by ensuring the filter and tubing are clean. Use prescribed medication concentration and avoid overfilling the cup; regular filter replacement and cleaning keep the nebulisation rate (approx. 0.3 ml/min) consistent.

Which accessories and replacement parts are compatible with the beurer Nebuliser IH 26?

Use original Beurer IH 26 accessories: nebuliser bottle and insert, adult and child masks, mouthpiece, nasal douche, compressed air tube, and replacement filter. The IH 26 requires compatible Beurer atomisers and components designed for this model to ensure correct fit, aerosol particle size and safe operation. Non‑compatible parts may affect performance and void warranties.

How often should I clean and disinfect the beurer Nebuliser IH 26 and its accessories?

Clean the nebuliser bottle, mouthpiece, masks, and nebuliser insert after every treatment to maintain hygiene and performance; disinfection is recommended after the last daily treatment or when required by your healthcare provider. The compressor housing should be wiped externally when needed and the air filter inspected regularly and replaced if dirty to prevent reduced airflow.

Why does the beurer Nebuliser IH 26 make unusual noises or vibrate more than usual?

Some operational noise is normal for a compressor-type nebuliser, but increased vibration or new rattling may indicate a loose accessory, misassembled nebuliser cup, obstructed air intake, or a clogged/replaced filter that needs seating. Turn off the unit, check fittings and tubing, reseat components, replace a dirty filter and restart; if excessive noise continues, stop use and contact Beurer service.

What maintenance schedule and safety precautions should I follow to extend the life of my beurer Nebuliser IH 26?

Replace the intake filter per the manual or sooner if visibly soiled, clean and disinfect nebuliser parts daily, and store accessories in the provided bag when dry. Allow the compressor to rest after 30 minutes of continuous use (device is not designed for permanent operation). Always disconnect power before maintenance and use only manufacturer‑approved parts to ensure safe, long-lasting performance.

More beurer manuals